You are on page 1of 4

Code: LLM18-QP-04.

14/FU
Rev.: 0
Date :
Total Page: 1

FIT-UP DIMENSIONAL INSPECTION


REPORT
Report No.: FU-022
Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-FU-022 (attached)

Item: GROUND SUPPORT OF DUCT

Drawing No.: AJ-2440-Z30-005

No.

Location

Drawing Dim.

L1

2000

L2

8556

10

L3

2852

L4

2852

L5

8556

10

L6

2852

L7

2852

L8

8712

10

L9

8712

10

10

L10

2000

11

L11

8556

10

12

L12

2852

13

L13

2852

14

L14

8556

10

15

L15

2852

16

L16

2852

17

L17

8712

10

18

L18

8712

10

19

L19

2200

20

L20

2200

21

L21

2200

22

L22

2200

23

L23

2546

24

L24

2546

Actual Dim.

Deviation

Tolerance

Result

Note: Application standard EN ISO 13920:1996 class B.


Measurement implement: Metal tape.
LILAMA 18
Prepared

VKS

Inspected/Reviewed

Reviewed/Approved

Sign:

Sign:

Name:
Date:

Name:
Date:
Page 1/4

Remarks

Code: LLM18-QP-04.14/DI
Rev.: 0
Date:
Total Page: 1

FINAL DIMENSIONAL INSPECTION


REPORT
Report No.:DI - 022
Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-DI-022 (attached)

Item: GROUND SUPPORT OF DUCT

Drawing No.: AJ-2440-Z30-005

No.

Location

Drawing Dim.

L1

8556

10

L2

2852

L3

2852

L4

8556

10

L5

2852

L6

2852

L7

8556

10

L8

2852

L9

2852

10

L10

8556

10

11

L11

2852

12

L12

2852

13

L13

2200

14

L14

2200

15

L15

2200

16

L16

2200

17

L17

2900

18

L18

70

19

L19

2760

20

L20

1350

21

L21

70

22

L22

1760

23

L23

179

24

L24

179

25

L25

80

26

L26

80

Actual Dim.

Deviation

LILAMA 18
Prepared

Tolerance

Result

VKS

Inspected/Reviewed

Reviewed/Approved

Sign:

Sign:

Name:

Name:

Date:

Date:

Page 2/4

Remarks

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD


Record No.: VI-022

Rev: 0
Date:
Total page: 2

Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2440-Z30-005

Item: GROUND SUPPORT OF DUCT

Weld joint: AJ-2440-Z30-005-J1.. (att.)

Test & Inspection


procedure

Item
No.
A

Acc.

Rej.

VISUAL CHECK FOR WELD


Fillet weld (leg length or throat
depth)

Acceptance criteria

Intermittent weld
a) Intermittent pitch
b) Weld length

Linear misalignment in
butt weld

Leg length and throat depth shall not be


less than design dimensions on drawing.
When not specified on drawing, throat
depth shall be minimum 0.7t. Where t:
thickness of a thinner plate at welded
plates.
Intermittent pitch shall be between +/-10
mm of design values on drawing.
Weld length shall be between -5 and
+10 mm of design values on drawing.
Linear misalignment shall be not excess
10% of plate thickness at welds, but
maximum 3.0mm.

Unevenness in bead surface


Depth D shall be 2 mm or less for
50mm long weld.

4
Irregularity in bead width
5

Difference in bead widths (a - b) shall be


5 mm
or less for 50 mm long weld.
a b < 3 mm

Overlap
Overlap shall be 1.5 mm. or less per 100
mm long in bead direction.

6
Undercut

Depth of undercut shall be 1.0 mm or


less.

7
Crater treatment
8

Craters shall have been treated.

Pit

No pits shall exist.

10

Slag inclusion

No included slag shall exist.

11

Crack

No cracks shall exist.

12

Spatter

Spatters shall be removed.


Conclusion

Accepted

Rejected

Remark

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD

Rev: 0
Date:
Total page: 2

Record No.: VI-022


Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2440-Z30-005

Item: GROUND SUPPORT OF DUCT

Weld joint: AJ-2440-Z30-005-J1.. (att.)

Item
No.

Test & Inspection


procedure

Acceptance criteria

Acc.

VISUAL CHECK FOR SHAPE/SIZE

Contused wound, hammer


wound, irregularity, etc.

These wounds shall be ground for


inconspicuous and smooth surfaces.

Finished conditions after


removing temporary jigs used
during manufacture.

Smoothing shall reach the base


metal. Concave portions shall
be repaired

Contamination, stuck foreign


Cleaning has been done. No foreign
materials, and foreign materials
materials shall exist.
left in equipment.

Inclination, bend and deflection.

These defects shall not been visually


detected.

Matching marks:
1) Orientation marks
(00,900,1800,2700)
2) Center line mark

Marking shall be made.

Finished conditions at convex


and corner portions (for lined
products).

Finish shall be smooth (min. 2R).

Finished conditions at concave


and corner portions (for lined Finish shall be smooth (min. 5R).
products).

Corners in bolt holes mounting


strainers for water collecting
plates, lining attaching internal Parts to be lined shall have corners
parts, external surfaces of
chamfered (min. 1C).
flanges, and bolt holes in
flanges.
Conclusion
LILAMA 18
Prepared/Inspected

Sign
Name:
Date:

Inspected/Reviewed

Accepted

Rej.

Rejected

VKS
Reviewed/Approved

Remark

You might also like