Technical Information Sheet SF105DIN/A

SURGE FILTERS, LOW CURRENT

DINsafe
Specifications

Product Description
Novaris Technologies DINsafe power line surge filters
are designed for effective protection against induced
transient overvoltages caused by lightning and other
events on AC and DC power supply circuits.
Versions are available for voltage ratings up to 240V
AC and are housed in a rugged metal enclosure with
DIN43880 compliant dimensions.

Operation
Multistage transient protection is utilised in every unit.
Metal oxide varistors, as the first stage, absorb the
majority of the energy. These components are
continuously monitored for integrity with full
protection indicated by a green LED on the top of the
case. A red LED indicates power ON.

Description

Multistage power surge filter

No phases:

Voltage drop:

< 2V at full load

Efficiency:

99%

Earth leakage:

< 0.75mA

Protection modes:

Transverse and common mode

Protection stages:

MOV / low pass filter / MOV

Surge withstand:

IEEE C62.41 cat, A, B, opt. C


AS1768-1991 cat. A, B, opt. C

Surge rating:

16kA per line for 8/20us pulse


40kA per line for cat. C units

Let through voltage for 6kV 1.2/50us, 3kA 8/20us pulse:


< 680V
Response time:

3dB point at 800Hz

Indicators:

MOV integrity - green LED


Power ON - red LED

Alarm relay:

Clean contact with 4kV isolation


from active circuitry.

Dimensions:
SF105DIN-xxx/A:
SF110DIN-xxx/A:
SF120DIN-xxx/A:
Mounting:
Terminal capacity:
SF105DIN-xxx/A:
SF110DIN-xxx/A:
SF120DIN-xxx/A:
Location:

The first stage is followed by a low pass LC filter that


further attenuates the let through voltage. The filter
also attenuates low-level noise and harmonics.
The third stage comprises metal oxide varistors. These
provide a final clamping circuit and protect against
impulses generated by the connected load. This is
particularly important when multiple loads are
connected. Do not exceed total filter ratings.
10 amp and 20 amp filters also feature external alarms.
These provide a clean changeover contact that may be
used to remotely monitor the status of the filter or as a
power fail indicator. The relay is normally energised
when power is applied.

Instantaneous

Frequency response:

Cat No.

116H x 80D x 54W


116H x 80D x 120W
116H x 80D x 120W
DIN rail mountable. Panel mount
brackets are available on request.
2

4mm
2
16mm
2
16mm
Final subcircuits to AS1768 location
categories A and B, category C is
optional.

Options
Vmax AC

Current

Rating

SF105DIN-30V/A
SF105DIN-50V/A
SF105DIN-150V/A
SF105DIN/A
SF105DIN-16/A
SF105DIN-40/A

30V
50V
150V
250V
250V
250V

5A
5A
5A
5A
5A
5A

2kA
6.5kA
8kA
8kA
16kA
40kA

SF110DIN-30V/A
SF110DIN-150V/A
SF110DIN/A
SF110DIN-40/A

30V
150V
250V
250V

10A
10A
10A
10A

4kA
16kA
16kA
40kA

SF120DIN/A
SF120DIN-40/A

250V
250V

20A
20A

16kA
40kA

/A indicates LED display for 5A version


/A indicates LED display and external alarm for 10A and 20A
versions.
2Amp and 3Amp versions are also available on request.
Please contact Novaris for details.

Novaris Pty Ltd


72 Browns Road, Kingston, TAS. 7050
AUSTRALIA
Copyright 2000 Novaris

ABN:
TEL:
FAX:
E-mail:

33 065 427 232


+61 3 6229 7233
+61 3 6229 9245
sales@novaris.com.au

You might also like