INTRODUCTION :
Commissioning is a process of integrating site i.e downloading site codes to BTS,
calibration of TRX unit, measurement of VSWR, measurement of reverse power, documentation
of the site etc.
(900MHz)
(900MHz)
(900MHz & 1800MHz)
(900MHz & 1800MHz)
c.
For changing security level from one to third. Enter the following command;
disp_site
Device
------------DRI 0 0 0
DRI 0 1 0
DRI 0 2 0
DRI 0 3 0
DRI 1 0 0
DRI 1 1 0
DRI 1 2 0
DRI 1 3 0
DRI 2 0 0
DRI 2 1 0
DRI 2 2 0
DRI 2 3 0
State
----D-L
B-U
E-U
E-U
B-U
E-U
E-U
E-U
B-U
E-U
E-U
E-U
Reason
------------------------NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
NO REASON
S:Shutdown
Last Transition
dd/mm hh:mm:ss
--------------08/09 16:49:22
08/09 16:49:56
08/09 16:35:08
08/09 16:35:14
08/09 16:35:08
08/09 16:35:14
08/09 16:34:46
08/09 16:34:46
08/09 16:35:02
08/09 16:35:02
08/09 16:35:08
08/09 16:35:08
Related
Function
--------None
RTF 0 0 0
None
None
RTF 1 0 0
None
None
None
RTF 2 0 0
None
None
None
In the above massage, we see that there are twelve DRI are equipped. Four dris in
all sector. DRI with id starting from 0 is in first sector, similarly DRI with id
This command is used to check the status of all/particular rtf. This command gives the
status of the rtf.
Syntax & Massage after execution of this command is shown below:
3.
ADMIN STATES:
Function
------------RTF 0 0 0
RTF 1 0 0
RTF 2 0 0
Last Transition
dd/mm hh:mm:ss
--------------08/09 16:34:47
08/09 16:34:50
08/09 16:34:47
State
----B-E
B-E
B-E
Reason
------------------------NO REASON
NO REASON
NO REASON
DRI ID: 0 0 0
Data read from transceiver
Store Calibration Data:disabled
Calibration Data (All values in Hex):
Transmit Power Offsets =
3
Receiver System Data:
Antenna Number
1
2
3
4
E:Equipped
Related
Device
--------DRI 0 0 0
DRI 1 0 0
DRI 2 0 0
5.
This command is used to check how many calls are going on in all sectors.
Unbarred
Unbarred
EGPRS Unavail
Unbarred
Unbarred
EGPRS Unavail
PD Available
1
1
No
No
No
NA
NA
NA
None
4
Unavail
OFF
OFF
0
FREE
Unbarred
Unbarred
EGPRS
PD Available
1
1
No
No
No
NA
NA
NA
None
4
Unavail
OFF
OFF
0
INUSE UNAVL
PD
1
1
No
No
No
NA
NA
NA
None
4
Unavail
OFF
OFF
0
FREE
INUSE UNAVL
FREE
INUSE UNAVL
----- ----- ----- -SDCCH
0
Norm Outer TCH/F
0
Norm Inner TCH/F
0
Ext Outer TCH/F
0
PD CHANNEL
0
EGPRS PD CHANNEL
0
12
----- ----
14
14
18
21
17
End of Report.
Numbers of inuse traffic channels shows, numbers of calls going on in the all sectors. First group
shows first sectors, second group shows second sectors, and third group shows third sectors.
6.
This command is used to check numbers of time slots are active & call drop.
7.
This command is used to check equipage of the DRI. That give complete details of the
DRI.
Syntax & Massage after execution of this command is shown below:
MMI-RAM 1015 -> disp_eq 30 dri 2 1
DRI identifier: 2 1
DRI Density[dri_density]: double
Transceiver Flag: 0
Cabinet identifier: 2
Type of connection to the BTP: FMUX1
Port to which the TCU is connected[tcu_port]: 4
RTF identifier[pref_rtf_id]:
GSM cell ID where the DRI appears: 404 11 109 18523
Antenna select number for this cell[antenna_select]: 3
Tuneable combining used: No
8.
disp_int
Interval
-------0
1
2
3
4
5
6
7
8
9
10
11
9.
Start Time(HH:MM:SS)
-------------------14:00:00
14:30:00
15:00:00
15:30:00
16:00:00
16:30:00
17:00:00
17:30:00
18:00:00
12:30:00
13:00:00
13:30:00
DRI 2 2
dropped.
10.
COMMAND ACCEPTED
11.
DRI 0 1
Taking this DRI out of service may cause calls to be
dropped.
Are you sure (y=yes,n=no)? y
COMMAND ACCEPTED
12.
disp_stats (time interval) path_balance cell_number (MCC id) (MNC id) (LAC
id) (Cell id)
This command is used to check path balance of the sites. This command gives
balance value between TX path and RX path. The mean value of path balance
should be in the range of 108 to 112 for 900 MHz band. Path balance value 105 can
be acceptable if it is 1800 MHz band. Path balance command is separately entered
and executed for each sectors.
Syntax & Massage after execution of this command is shown below:
Command for sector first.
MMI-RAM 1015 -> disp_stats 2 path_balance cell_number 4 0 4 1 1 109
18521
SITE : 30
RTF ID : 0 0
SITE : 30
CELL #: LAC=006Dh CI=4859h
RTF ID : 0 0
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 111
Distribution Max. : 135
Distribution Min. : 81
Bin : 0 0 0 2 3137 5957 3 0 0 0
SITE : 30
RTF ID : 0 1
SITE : 30
CELL #: LAC=006Dh CI=4859h
RTF ID : 0 1
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 110
Distribution Max. : 129
Distribution Min. : 92
Bin : 0 0 0 0 4065 4442 0 0 0 0
SITE : 30
RTF ID : 0 2
SITE : 30
CELL #: LAC=006Dh CI=4859h
RTF ID : 0 2
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 109
Distribution Max. : 135
Distribution Min. : 92
Bin : 0 0 0 0 5065 4244 16 0 0 0
SITE : 30
RTF ID : 0 3
SITE : 30
CELL #: LAC=006Dh CI=4859h
RTF ID : 0 3
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 110
Distribution Max. : 133
Distribution Min. : 81
Bin : 0 0 0 26 6859 9906 1 0 0 0
Command for second sector.
MMI-RAM 1015 -> disp_stats 2 path_balance cell_number 4 0 4 1 1 109
18522
SITE : 30
RTF ID : 1 0
SITE : 30
CELL #: LAC=006Dh CI=485Ah
RTF ID : 1 0
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 111
SITE : 30
CELL #: LAC=006Dh CI=485Ah
RTF ID : 1 1
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 111
Distribution Max. : 127
Distribution Min. : 95
Bin : 0 0 0 0 553 1065 0 0 0 0
SITE : 30
RTF ID : 1 2
SITE : 30
CELL #: LAC=006Dh CI=485Ah
RTF ID : 1 2
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 112
Distribution Max. : 125
Distribution Min. : 96
Bin : 0 0 0 0 617 1904 0 0 0 0
SITE : 30
RTF ID : 1 3
SITE : 30
CELL #: LAC=006Dh CI=485Ah
RTF ID : 1 3
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 111
Distribution Max. : 141
Distribution Min. : 82
Bin : 0 0 0 69 7350 12118 63 0 0 0
Command for third sector.
MMI-RAM 1015 -> disp_stats 2 path_balance cell_number 4 0 4 1 1 109
18523
SITE : 30
RTF ID : 2 0
SITE : 30
10
SITE : 30
CELL #: LAC=006Dh CI=485Bh
RTF ID : 2 1
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 112
Distribution Max. : 138
Distribution Min. : 90
Bin : 0 0 0 0 2617 6593 17 0 0 0
SITE : 30
RTF ID : 2 2
SITE : 30
CELL #: LAC=006Dh CI=485Bh
RTF ID : 2 2
MEAS_TYPE : PATH_BALANCE
Distribution Mean : 113
Distribution Max. : 137
Distribution Min. : 93
Bin : 0 0 0 0 159 940 2 0 0 0
This command is used to check current active alarm of the site. It can be either external
alarm or internal alarm.
13.
Description
-------------------INTRUDER ALARM (11)
IAS 0 0 0
Multicoupler Failure
11
Clear
Type Tag(hex) Date/Time
---- -------- ---------FMIC Untagged 09-08-2004
16:32:58
41 FMIC Untagged 09-08-2004
This command is used to enabling alarm mode of the site. After enabling alarm mode
each and every alarm raised is appear on the screen. These alarms are either external or internal.
After enabling alarm mode, all the external alarm can be check by raising these from krone box.
14.
SITE
---30
MODE
--------------------------------------Alarm reporting enabled
When Opto 1 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 1 alarm clear from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 2 alarm raised from Krone box. A massage is appearing on the screen as shown below.
12
When Opto 3 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 3 alarm clear from Krone box. A massage is appearing on the screen as shown below.
* Device Alarm -- Untagged
*
* (18) Optocoupler 3
* -- Severity: CLEAR
Category: ENVIRONMENT
* -- EAS 0 0 0
* -- Site: 30
Cage: 15
Slot: 16
* -- Functional Unit: Site 30
13
When Opto 4 alarm clear from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 5 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 5 alarm clear from Krone box. A massage is appearing on the screen as shown below.
14
*
*
*
*
*
*
*
*
*
*
When Opto 6 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 6 alarm clear from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 7 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
15
Category: ENVIRONMENT
When Opto 8 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 8 alarm clear from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
16
When Opto 9 alarm clear from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 10 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 10 alarm clear from Krone box. A massage is appearing on the screen as shown below.
* Device Alarm -- Untagged
*
* (17) Optocoupler 2
17
--------
Severity: CLEAR
Category: ENVIRONMENT
EAS 1 0 0
Site: 30
Cage: 15
Slot: 17
Functional Unit: Site 30
Time: Wed 8/9/2004 21:02:48:190
Alarm Type: Fault Management Initiated Clear
Additional Info: DG FAIL to START (9)
When Opto 11 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 11 alarm clear from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
*
*
When Opto 12 alarm raised from Krone box. A massage is appearing on the screen as shown below.
*
*
*
*
*
*
*
*
18
14.
SITE
---30
MODE
--------------------------------------Alarm reporting disabled
C.
D.
19
FOE
.LMN3
SWAP C 0
EXEC C 0
.IGUANA
TEST
CSPWR
Press
UFor Up Calibration offset
DFor Down Calibration offset
Until the desired power is reached i.e 20W, note down the Calibration offset
F.
Press
ESC For Escape from calibration
G.
(i)
H.
I.
J.
K.
L.
SAVE CAL TX
B.
C.
D.
20
chg
pizza
cal_test_mode on
fm test_mode on
fm_test block none 0xff
E.
Press
UFor Up Calibration offset
DFor Down Calibration offset
Until the desired power is reached i.e 20W, note down the Calibration offset
F.
Press
Q For Escape from calibration
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
cal_store 1
fm test_mode off
cal_test_mode off
Connect the serial cable to the MMI port and lock the carrier unit
Now gives the hard reset to the carrier unit
Lock both the dri in the carrier unit
Unlock both the dri in the carrier unit
Check the cal data of the both dri when it is busy
The cal data must be (12+X), where X = offset given by you
The cal data shown in hexadecimal value
Only one dri is calibrate in one CTU, other dri automatically taken the value
for first dri
Now repeat the action for the all carrier units
21
C.
D.
E.
chg
pizza
cal_test_mode on
fm test_mode on
fm_test block none 0xff
cal_config tx_cab_mode single
cal_cabinet tx_cab
Press
UFor Up Calibration offset
DFor Down Calibration offset
Press the D key until 16 offset is achieve and then Press
H.
I.
J.
K.
L.
L.
22
cal_store 1
fm test_mode off
cal_test_mode off
Connect the serial cable to the MMI port and lock the carrier unit
Now gives the hard reset to the carrier unit
Lock the carrier unit
Connect the power meter and then
Unlock the carrier unit till dri is busy and then gives the BCCH channels to
this dri.
Check the power on the power meter if it is 20Watt then ok, otherwise
observe either power is less then 20 Watt or more then 20 Watt. If it is less
then 20 Watt then again dummy calibrate and set offset below 16 value. If it
is more then 20 Watt then again dummy calibrate and set offset beyond 16
value.
D.
E.
(i)
tcu_clock 0
Change the position of the toggle switch
F.
G.
.GSMFW
TEST
ACT C
BBH ALARM OFF
CSPWR
Press
UFor Up Calibration offset
DFor Down Calibration offset
Until the desired power is reached i.e 20W, note down the Calibration offset
H.
23
Press
ESC For Escape from calibration
I.
J.
K.
L.
M.
24
(i)
HALT C
(ii)
WRENB
(iii) SAVE CAL TX
(iv)
WRPTC
Connect the serial cable to the MMI port
Give the hard reset to the carrier unit
Check the cal data of the carrier when it is busy
Repeat the action for the all carrier units