You are on page 1of 2

Design Calculation Sheet

Project no.:
Subject:

D0521-4.2-6
Date:
External wall U value based on Insualted block

10-Jul-07

Sheet No.:

External Wall
Insualated Hollow
Block
Outside

Inside

1.5 cm

Plaster

1.5cm

20 cm

Insulated Block

RValues(F.ft2.hr/Btu)

Material

Plaster

R-Values (m2*k/W)

Outdoor Air Film

0.25

0.04403

15mm Plaster

0.118

0.020782

20 cm Insulated block

11.978

2.109546

15mm Plaster

0.118

0.020782

Indoor Air Film

0.98

0.172596

RT =

13.444

F.ft2.hr/Btu =>

RT = 2.3677351 (m2*k/W) =>

U=
U=

1 of 1

Computed by:
Checked by:
Approved by: