Professional Documents
Culture Documents
NEC Pasolink
NEC Pasolink
ROI-S05748-056E
April, 2006
PASOLINK NEO
6-52 GHz PDH/SDH DIGITAL RADIO SYSTEM
Section I DESCRIPTION
CONTENTS
TITLE
PAGE
2.1
2.2
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
2.2.6
2.2.7
2.2.8
2.4.1
10 dB Coupler 2-32
2.4.2
2.5
2.6
CL-1
CONTENTS
ROI-S05748
CL-2
2 pages
GENERAL DESCRIPTION
ROI-S05748
1. GENERAL DESCRIPTION
This section provides descriptive information on the PASOLINK NEO
radios which are used for the wide/narrow band point-to-point digital
microwave radio links.
The Indoor Unit (IDU) provides digital PDH (5-48 E1, 1/2 E3), SDH
(1/2 STM-1) and LAN (2 10/100Base-TX) signal transmission by the
change of the data signal interface card. It can select the modulation
method QPSK/16QAM/32QAM/128QAM, by software selection
depending on the transmission capacity that is configured in the
modulator/demodulator unit.
The Outdoor Unit (ODU) can be applied for a wide range of RF frequency
bands from 6/7/8/10/11/13/15/18/23/26/32/38/52 GHz.
Applications using the following redundancy configurations, Unprotected
(1+0), 2 (1+0)* and Protected (1+1), 2 (1+1)* are available for
PASOLINK NEO radio systems.
Note: * XPIC
Cross Polarization Interference Canceller (XPIC) system is applied for
dual polarized systems using the same frequency in 2 (1+0) and 2
(1+1) configurations.
1-1
GENERAL DESCRIPTION
ROI-S05748
PASOLINK NEO
0678
IDU Package Label
0678
PASOLINK NEO
MDP-150MB-1AA INDOOR UNIT
PASOLINK NEO
MDP-150MB-1AA INDOOR UNIT
1+0
1+1
XPIC
ETSI (RACK)
LABEL( EN
FR
ES
DE
IT)
INTFC(1)
STM1-E
STM1-0
LAN/WS GbE
16E1(
)
48E1 OTHER(
)
INTFC(2)
STM1-0
LAN/WS OTHER(
)
1+0
1+1
XPIC
ETSI (RACK)
LABEL( EN
FR
ES
DE
IT)
INTFC(1)
STM1-E
STM1-0
LAN/WS GbE
16E1(
)
48E1 OTHER(
)
INTFC(2)
STM1-0
LAN/WS OTHER(
)
MADE IN JAPAN
NWM-001846-001
MODEM(1)
MDP-150MB-1AA
INDOOR UNIT
INTFC (2)
INTFC (1)
MADE IN JAPAN
NWM-001846-001
SER. No.
0678
(H2930)
DATE
CTRL
MODEM(2)
48 V
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
G PULL
ALM
PWR
2M IN/OUT-B
2M IN/OUT-A
PORT 1
PROTECT
PORT 2
(Blank)
LCT
NMS
NE
100M
100M
MADE IN JAPAN
PASOLINK NEO
MAINT
MEMORY
IDU
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
IDU 1+0
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
G PULL
! IF IN/OUT
ALM
PWR
2M IN/OUT-B
2M IN/OUT-A
100M
PORT 1
PORT 2
PROTECT
PULL
PWR
LCT
NMS
NE
SC IN/OUT
SERIAL No.
PASOLINK NEO
0678
TRP-( )G-1B
OUTDOOR UNIT (NHG)
SHIFT FREQUENCY
(NWA-009034)
TX
HIGH/LOW
EOW
CALL
CAUTION
Non-ionizing
radiation
(NWA-009034)
TX FREQUENCY
SERIAL No.
-48V INPUT
CAUTION
Non-ionizing
radiation
ODU
IFL
TX
HIGH/LOW
DATE
MADE IN JAPAN
RX LEV
MON
1-2
2 pages
0678
TRP-( )G-1B
OUTDOOR UNIT (NHG)
SHIFT FREQUENCY
DATE
PASOLINK NEO
MAINT
MEMORY
IDU
AUX/ALM
IDU 1+1
PASOLINK NEO
100M
FG
MADE IN JAPAN
-48V INPUT
Power down IDU before
disconnection or
connection of cable.
MMC
XPIC CTRL
PWR
ODU
MD/
CBL SELV
TX
RX
XPIC
RESET
ROI-S05748
Refer to
Fig. 2-1
Fig. 2-2
Fig. 2-3
Fig. 2-4
Fig. 2-5
Fig. 2-6
Fig. 2-7
Fig. 2-8
Fig. 2-9
2-1
RF Cable
1+0 IDU
DATA
IN/OUT
RF Cable
f1
IF Cable
IDU
f1
ROI-S05748
ODU
ODU
1+0 IDU
IF Cable
IDU
DATA
IN/OUT
1+0 IDU
f1
IF Cable
IDU
ODU
ODU
f1
IF Cable
IDU
DATA
IN/OUT
1+1 IDU
IF Cable
ODU (Working)
No.1
DATA
IN/OUT
RF Cable
f1
HYB
ODU (Working)
HYB
IF Cable
No.1
RF Cable
f1
No.2
IF Cable
ODU (Standby)
No.2
ODU (Standby)
DATA
IN/OUT
IF Cable
1+1 IDU
IF Cable
No.1
DATA
IN/OUT
ODU (Working)
HYB
No.2
IF Cable
f1
f1
ODU (Standby)
ODU (Working)
IF Cable
No.1
HYB
ODU (Standby)
No.2
DATA
IN/OUT
IF Cable
1+1 IDU
IF Cable
No.1
DATA
IN/OUT
ODU (Working)
HYB
No.2
IF Cable
f1
f1
f1
ODU (Standby)
ODU (Working)
IF Cable
No.1
IF Cable
No.2
DATA
IN/OUT
ODU (Standby)
No.2
ODU (Working)
f1
f1
1+1 IDU
ODU (Working)
IF Cable
No.1
IF Cable
IF Cable
ODU (Standby)
No.2
DATA
IN/OUT
ODU (Standby)
1+1 IDU
IF Cable
No.1
DATA
IN/OUT
ODU (Working)
HYB
No.2
IF Cable
ODU (Working)
f1
f2
f1
f2
ODU (Working)
IF Cable
No.1
HYB
ODU (Working)
No.2
IF Cable
2-2
DATA
IN/OUT
ROI-S05748
1+0 IDU
DATA1
IN/OUT
IDU XPIC
CTRL
Cable
DATA2
IN/OUT
IDU
IDU
X IF Cable
1+0 IDU
IF Cable
ODU (Working)
V (H)
OMT
IF Cable
f1
f1
f1
f1
V (H)
IF Cable
ODU (Working)
IDU
IDU XPIC
IDU
X IF Cable CTRL
Cable
OMT
H (V) ODU (Working)
DATA1
IN/OUT
IF Cable
IDU
IDU
1+0 IDU
1+0 IDU
DATA2
IN/OUT
f1
f1
f1
f1
RF Cable
IDU XPIC
IDU
CTRL
X IF Cable
Cable
DATA2
IN/OUT
1+0 IDU
IF Cable
IDU
IF Cable
IF Cable
IDU
RF Cable
H (V) ODU (Working)
DATA1
IN/OUT
IDU
IDU XPIC
X IF Cable CTRL
Cable
IF Cable
IDU
IDU
1+0 IDU
1+0 IDU
DATA2
IN/OUT
1+0 IDU
DATA1
IN/OUT
1+0 IDU
IF Cable
IDU
IDU XPIC
IDU
CTRL
X IF Cable
Cable
OMT
IF Cable
DATA2
IN/OUT
f1
f1
f1
f1
IF Cable
IDU
OMT
H (V) ODU (Working)
IDU
IDU XPIC
X IF Cable CTRL
Cable
DATA2
IDU
IN/OUT
IF Cable
IDU
1+0 IDU
DATA1
IN/OUT
1+0 IDU
HYB
No.2
ODU (Standby)
V (H)
No. 1
IDU
X IF Cable
H (V)
No. 2
No.1
DATA2
IN/OUT
V (H)
No. 1
ODU (Working)
ODU (Working)
HYB
No.2
IF Cable
1+1 IDU
ODU (Standby)
No. 2
H (V)
V (H)
f1
f1
f1
f1
No. 1
ODU (Working)
1+1 IDU
IF Cable
No.1
HYB
No.2
ODU (Standby)
V (H)
No. 1
H (V)
No. 2
IDU
X IF Cable
HYB
ODU (Standby)
No. 2
IDU XPIC
CTRL
Cable
No.1
ODU (Working)
H (V)
DATA1
IN/OUT
No.2
DATA2
IN/OUT
IF Cable
1+1 IDU
2-3
ROI-S05748
IDU
QPSK/16QAM
QPSK/16QAM/32QAM
128QAM
ODU
128QAM
128QAM
QPSK/16/32/128QAM
QPSK/16/32/128QAM
6 HK IN/4 Cluster IN
QPSK/16/32/128QAM
1+0/1+1 Configuration
Fig. 2-2 Signal Interface/Capacity (1/2)
2-4
ROI-S05748
IDU
No.1
128QAM
6 to 52 GHz
ODU
6 HK IN/4 Cluster IN
OMT
IDU
ODU
No.2
128QAM
XPIC Configuration
Fig. 2-2 Signal Interface/Capacity (2/2)
2-5
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
ROI-S05748
PULL
(Blank)
ALM
PWR
STM-1 IN
STM-1 OUT
PROTECT
(Blank)
LCT
NMS
NE
PASOLINK NEO
MAINT
MEMORY
IDU
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
ALM
PWR
STM-1 IN
STM-1 OUT
ALM
STM-1 OUT
ONLINE
STM-1 IN
PROTECT
PASOLINK NEO
MAINT
MEMORY
IDU
(Blank)
LCT
NMS
NE
ONLINE
XPIC CTRL
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
G PULL
ALM
2M IN/OUT-B
2M IN/OUT-A
PWR
PORT 1
PROTECT
(Blank)
LCT
NMS
NE
PORT 2
100M
100M
XPIC CTRL
PASOLINK NEO
MAINT
MEMORY
IDU
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
ALM
2M IN/OUT-B
2M IN/OUT-A
PWR
2M IN/OUT-C
PROTECT
PASOLINK NEO
MAINT
MEMORY
IDU
(Blank)
LCT
NMS
NE
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
E3 CH1
E3 CH2
ALM
PWR
IN
IN
WS IN/OUT
OUT
100M
PORT 1
PROTECT
PORT 2
PASOLINK NEO
MAINT
MEMORY
IDU
(Blank)
LCT
NMS
NE
100M
OUT
XPIC CTRL
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
(Blank)
ALM
PWR
STM-1 IN
STM-1 OUT
PROTECT
PASOLINK NEO
MAINT
MEMORY
IDU
(Blank)
LCT
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
NMS
NE
AUX/ALM
SC IN/OUT
PULL
STM-1 IN
CALL
MMC
(Blank)
ALM
PWR
EOW
STM-1 OUT
PROTECT
PASOLINK NEO
MAINT
MEMORY
IDU
(Blank)
LCT
NMS
NE
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
(Blank)
ALM
PWR
STM-1 IN
STM-1 OUT
43V
STD
G
OUT
PWR
ALM
FUSE (250V/8AH)
SELV
PROTECT
PULL
PWR
LCT
NMS
NE
AUX/ALM
EOW
2-6
PASOLINK NEO
MAINT
MEMORY
IDU
SC IN/OUT
CALL
MMC
ROI-S05748
! IF IN/OUT
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
XPIC CTRL
PULL
(Blank)
ALM
PWR
STM-1 IN
STM-1 OUT
! IF IN/OUT
PROTECT
PULL
PWR
LCT
NMS
NE
AUX/ALM
SC IN/OUT
PASOLINK NEO
MAINT
MEMORY
IDU
EOW
CALL
MMC
XPIC CTRL
TX
RX
XPIC
RESET
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
! IF IN/OUT
PWR
ODU
MD/
CBL SELV
PULL
ALM
PWR
STM-1 OUT
STM-1 IN
ALM
STM-1 OUT
ONLINE
PWR
STM-1 IN
PROTECT
PULL
LCT
NMS
NE
AUX/ALM
SC IN/OUT
ONLINE
PASOLINK NEO
MAINT
MEMORY
IDU
EOW
CALL
MMC
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
G PULL
ALM
PWR
2M IN/OUT-B
2M IN/OUT-A
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PORT 1
PROTECT
PULL
PORT 2
PWR
LCT
NMS
NE
100M
100M
PASOLINK NEO
MAINT
MEMORY
IDU
AUX/ALM
SC IN/OUT
EOW
CALL
MMC
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
ALM
2M IN/OUT-B
2M IN/OUT-A
PWR
2M IN/OUT-C
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PROTECT
PULL
PWR
LCT
NMS
NE
AUX/ALM
SC IN/OUT
PASOLINK NEO
MAINT
MEMORY
IDU
EOW
CALL
MMC
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
E3 CH1
IN
OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
IN
WS IN/OUT
OUT
PWR
100M
PORT 1
PROTECT
PULL
LCT
NMS
NE
AUX/ALM
SC IN/OUT
EOW
CALL
PORT 2
100M
! IF IN/OUT
E3 CH2
ALM
PWR
XPIC CTRL
PASOLINK NEO
MAINT
MEMORY
IDU
MMC
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
PULL
(Blank)
ALM
PWR
STM-1 IN
STM-1 OUT
! IF IN/OUT
XPIC CTRL
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
TX
RX
XPIC
RESET
PWR
ODU
MD/
CBL SELV
XPIC CTRL
PWR
ODU
MD/
CBL SELV
XPIC CTRL
TX
RX
XPIC
RESET
! IF IN/OUT
PROTECT
PULL
PWR
LCT
NMS
NE
AUX/ALM
SC IN/OUT
PASOLINK NEO
MAINT
MEMORY
IDU
EOW
CALL
MMC
PULL
(Blank)
ALM
PWR
STM-1 IN
STM-1 OUT
! IF IN/OUT
PROTECT
PULL
PWR
LCT
NMS
NE
AUX/ALM
SC IN/OUT
PASOLINK NEO
MAINT
MEMORY
IDU
EOW
CALL
MMC
2-7
ROI-S05748
ODU
ODU
ODU
Antenna
ODU
OMT
Antenna Direct Mounting 2(1+0)
Dual Pol. Antenna
OMT
ODU
ODU
2-8
ROI-S05748
ODU
HYB
ODU
ODU
ODU
HYB
Antenna Direct Mounting (1+1)
2-9
ODU
ODU
ODU
ODU
2-10
ROI-S05748
ROI-S05748
6 to 52 GHz
16E1+2PORT LAN/
48E1/
1/2E3
fL(H)
ODU
IDU
MODEM
( )INTFC *
QPSK/
16QAM/
32QAM/
MODEM
DPU/
FEC
IN/OUT
fH(L)
ODU
INTFC
BPF
(TX)
ODU
INTFC
RF
CKT
LPF/EQL
BPF
(RX)
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW
DC-DC
CONV
CTRL
SYNTH
(LO)
PS
EOW
(JACK)
CTRL
PS IN
Note: * Optional
1+0 CONFIGURATION FOR PDH
6 to 52 GHz
IDU
STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE
MODEM
( )INTFC *1
IN/OUT
STM-1 (OPT)
fL(H)
ODU
DPU/
FEC
128QAM
MODEM
fH(L)
ODU
INTFC
RF
CKT
LPF/EQL
( )INTFC *2
BPF
(TX)
ODU
INTFC
DC-DC
CONV
SYNTH
(LO)
PS
WS/SC-LAN
BPF
(RX)
LAN/WS INTFC *3
CTRL
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW
CTRL
EOW
(JACK)
PS IN
Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals
2-11
ROI-S05748
ODU
IDU
HYB
MODEM
16E1+2PORT LAN/
48E1/
1/2E3
DPU/
FEC
( )INTFC *
IN/OUT
QPSK/
16QAM/
32QAM/
MODEM
ODU
INTFC
BPF
(TX)
ODU
INTFC
RF
CKT
BPF
(RX)
LPF/EQL
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW
DC-DC
CONV
CTRL
SYNTH
(LO)
PS
EOW
(JACK)
6 to 52 GHz
CTRL
fL(H)
PS IN
ODU
fH(L)
MODEM
DPU/
FEC
QPSK/
16QAM/
32QAM/
MODEM
ODU
INTFC
BPF
(TX)
ODU
INTFC
RF
CKT
BPF
(RX)
LPF/EQL
DC-DC
CONV
SYNTH
(LO)
PS
PS IN
CTRL
Note:
* :Optional
2-12
ROI-S05748
ODU
IDU
STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE
IN/OUT
HYB
MODEM
( )INTFC *1
DPU/
FEC
128QAM/
MODEM
ODU
INTFC
BPF
(TX)
ODU
INTFC
RF
CKT
BPF
(RX)
LPF/EQL
STM-1 (OPT)
( )INTFC *2
DC-DC
CONV
SYNTH
(LO)
PS
WS/SC-LAN
LAN/WS INTFC *3
6 to 52 GHz
CTRL
fL(H)
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW
fH(L)
CTRL
EOW
(JACK)
PS IN
ODU
MODEM
DPU/
FEC
128QAM/
MODEM
ODU
INTFC
BPF
(TX)
ODU
INTFC
RF
CKT
BPF
(RX)
LPF/EQL
DC-DC
CONV
SYNTH
(LO)
PS
PS IN
CTRL
Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals
2-13
ODU
IDU
STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE
IN/OUT
( )INTFC *1
128QAM/
MODEM
ODU
INTFC
BPF
(TX)
ODU
INTFC
RF
CKT
BPF
(RX)
( )INTFC *2
DC-DC
CONV
SYNTH
(LO)
PS
WS/SC-LAN
OMT
MODEM
DPU/
FEC
LPF/EQL
STM-1 (OPT)
ROI-S05748
LAN/WS INTFC *3
6 to 52 GHz
CTRL
fL(H)
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW
fH(L)
CTRL
EOW
(JACK)
PS IN
IDU
ODU
MODEM
STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE
128QAM/
MODEM
( )INTFC *1
IN/OUT
STM-1 (OPT)
DPU/
FEC
ODU
INTFC
BPF
(TX)
ODU
INTFC
RF
CKT
LPF/EQL
BPF
(RX)
DC-DC
CONV
( )INTFC *2
SYNTH
(LO)
PS
CTRL
WS/SC-LAN
LAN/WS INTFC *3
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW
CTRL
EOW
(JACK)
PS IN
Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals
2-14
V(H)
H(V)
H(V)
V(H)
ROI-S05748
LAN *2
PDH
Capacity
Up to 100 Mbps
Interface
Environmental
Requirement
QPSK
RJ-45
10/100 Base-T(X)
16 QAM
32 QAM
28 (27.5) MHz
128 QAM
Not Applicable
Guaranteed
Operation
ODU: 33 to +50C
IDU: 5 to +50C
Workable
Operation
ODU: 40 to +55C
IDU: 10 to +55C
Transportation/
Storage
Relative
humidity
EMC
Safety
Conforms to EN60950
48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2
Power Requirement
Power Consumption (Typical)
ODU/Unit
IDU Card/Unit
MODEM
10 W
8W
8W
E3 INTFC
8W
CTRL
Mechanical
Dimension
7W
MODEM: 0.5 kg, 48E1 INTFC (for 48 E1): 0.4 kg, 16E1 INTFC (for 16 E1): 0.4 kg,
E3 INTFC (for E3): 0.4 kg, CTRL: 0.4 kg
Weight/Card
ODU
IDU
2-15
ROI-S05748
SDH
LAN
Capacity
155 Mbps *2
Up to 150 Mbps
Interface
Optical: LC
Electrical: IEC 169-29(1.0/2.3)
Up to 2 STM-1 *3
RJ-45
10/100/1000 Base-T(X)
LC: 1000 Base-SX
QPSK (PDH)
16QAM (PDH)
Not Applicable
32QAM (PDH)
128QAM
Environmental
Requirement
28 (27.5) MHz
28 (27.5) MHz
Guaranteed
Operation
ODU: 33 to +50C
IDU: 5 to +50C
Workable
Operation
ODU: 40 to +55C
IDU: 10 to +55C
ODU, IDU: 40 to +70C
Transportation/
Storage
Relative
humidity
EMC
Safety
Conforms to EN60950
48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2
Power Requirement
Power Consumption (Typical)
ODU/Unit
IDU Card/Unit
MODEM
10 W
STM-1O INTFC
5W
STM-1E INTFC
5W
LAN/WS INTFC
CTRL
MODEM: 0.5 kg, STM-1O INTFC: 0.3 kg, STM-1E INTFC: 0.3 kg,
LAN/WS INTFC: 0.3 kg, CTRL: 0.4 kg
Weight/Card
Mechanical
Dimension
ODU
IDU
2-16
5W
7W
ROI-S05748
LAN Setting
LAN capacity [Mbps]
Port 1
Port 2
150
P1 = 75 M separated
P2 = 75 M separated
150
P1 = 100 M separated
P2 = 50 M separated
150
P1 = 100 M separated
Disabled
100
2-17
ROI-S05748
LAN Setting
LAN capacity
[Mbps]
E1 capacity
[channels]
P1 & P2 = 80 M shared *1
80
(2 Mbps step)
(1 channel step)
48
16
Port 1
Port 2
P1 = 40M separated
P2 = 40M separated
80
P1 = 30M separated
P2 = 30M separated
60
10
P1 = 24M separated
P2 = 24M separated
48
16
Disabled
Disabled
16
*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)
(2) 2 Port LAN with PDH INTFC
Table 2-4 2 Port LAN 40 Mbps (16QAM/QPSK)
LAN Setting
LAN capacity
[Mbps]
E1 capacity
[channels]
P1 & P2 = 40 M shared *1
40
(2 Mbps step)
(1 channel step)
P1 & P2 = 8M shared
16
Port 1
Port 2
P1 = 20M separated
P2 = 20M separated
40
P1 = 10M separated
P2 = 10M separated
20
10
P1 = 4M separated
P2 = 4M separated
16
Disabled
Disabled
16
*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)
2-18
ROI-S05748
LAN Setting
LAN capacity
[Mbps]
E1 capacity
[channels]
20
(2 Mbps step)
(1 channel step)
P1 & P2 = 2M shared
Port 1
Port 2
P1 = 10M separated
P2 = 10M separated
20
Disabled
Disabled
10
LAN Setting
LAN capacity
[Mbps]
E1 capacity
[channels]
10
(2 Mbps step)
(1 channel step)
P1 & P2 = 2M shared
Disabled
Port 1
Disabled
Port 2
Type
Throughput
150 Mbps
150 Mbps
Connector type
LC
RJ-45
Port Number
1 port
1 port
2-19
ROI-S05748
SC5
: EOW 1 channel
Connector
LAN Interface
: SC LAN Interface
(in case of using SC LAN sub interface)
(Only for 155 Mbps capacity, throughput:
64/128/192/256 kbps or 2 Mbps)
: Connector RJ-45
2-20
ROI-S05748
Input port
Cluster ALM
IN/OUT
Connector
: 4 items (max.)
(Up to four cluster alarms are provided. For each
cluster alarm IN corresponding cluster alarm OUT
should be assigned in the opposite station.
: High Density D-sub 44 ways
2.2.6.3 Wayside
In case of 155 Mbps capacity, one (1) wayside channel can be used as E1
using optional LAN/WS interface card.
In case of 2E3 INTFC, eight (8) wayside channels can be used as E1 or
LAN INTFC
In case of 1E3 INTFC, four (4) wayside channels can be used as E1 or
LAN INTFC
2-21
ROI-S05748
Interface
type
Direct
Mount
Remote
mount
*2
7-8
10-11
13
15
18
23
26
28
32
38
52
Guaranteed
5.9257.11
7.128.5
10.1511.7
12.7513.25
14.2515.35
17.719.7
21.323.6
24.2527.5
27.529.5
31.833.4
37.040.0
51.452.6
N/A
N/A
N type N type
or
or
PDR 70 PDR 84
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320
N/A
+29
+25
+25
+23
+24
+24
+22
+22
+22
+18
+3
6-26G:1.5 dB
28-52G:+1.5/2.5 dB
*4
0 to 10 dB
1.0 dB
*4
0 to 10 dB
*3
0 to 30 dB
ATPC (1 dB step)
0 to 30 dB
0 to 25 dB
*3
0 to 25 dB
6 ppm
Frequency Stability
28 (27.5)
10 ppm
-6
(dBm), (Measured at ODU input port) at BER = 10
Threshold Level
Channel Separation (CS)=
NEC Original
84
83
83
83.5
83.5
83.5
83
83
81.5
81.5
78
87
86
86
86.5
86.5
86.5
86
86
84.5
84.5
81
90
89
89
89.5
89.5
89.5
89
89
87.5
87.5
84
*1 MHz
+3.0 dB
14 (13.75)
*1
MHz
7 MHz
BER = 10-3
-6
System Gain
*1
14 (13.75)
*1
113
108
108
106.5
107.5
107.5
105
105
103.5
99.5
81
116
111
111
109.5
110.5
110.5
108
108
106.5
102.5
84
119
114
114
112.5
113.5
113.5
111
111
109.5
105.5
87
MHz
MHz
7 MHz
BER = 10-3
Residual BER
2-22
Less than 10
6-26G:3.0 dB
28-52G:4.0 dB
*1
*2
*3
*4
ROI-S05748
Interface
type
Direct
Mount
Remote
*2
mount
7-8
10-11
13
15
18
23
26
28
32
38
Guaranteed
5.9257.11
7.128.5
10.1511.7
12.7513.25
14.2515.35
17.719.7
21.323.6
24.2527.5
27.529.5
31.833.4
37.040.0
N/A
N/A
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320
+26
+21.5
+22.5
+22.5
+22
+22
+20
+18
+17
+14.5 6-26G:1.5 dB
28-38G:+1.5/2.5 dB
*3
1.0 dB
*3
0 to 24 dB
ATPC range
0 to 24 dB
6 ppm
Frequency Stability
*1
14 (13.75)
76
76
76.5
76.5
76.5
76
76
74.5
74.5
80
79
79
79.5
79.5
79.5
79
79
77.5
77.5
83
82
82
82.5
82.5
82.5
82
82
80.5
80.5
86
85
85
85.5
85.5
85.5
85
85
83.5
83.5
MHz
*1
MHz
7 MHz
3.5 MHz
BER = 10
10 ppm
-6
Threshold Level
28 (27.5)
-6
97.5
98.5
99
98.5
98.5
96
94
91.5
89
*1 MHz
14 (13.75)
106
100.5
101.5
102
101.5
101.5
99
97
94.5
92
7 MHz
109
103.5
104.5
105
104.5
104.5
102
100
97.5
95
3.5 MHz
112
106.5
107.5
108
107.5
107.5
105
103
10.5
98
*1
+3.0 dB
-3
System Gain
28 (27.5)
N type N type
or
or
PDR 70 PDR 84
NEC Original
MHz
3.0 dB
BER = 10-3
Residual BER
Less than 10
at RSL = 30 dBm
*1
*2
*3
2-23
ROI-S05748
Interface
type
Direct
Mount
Remote
*2
mount
7-8
10-11
13
15
18
23
26
28
32
38
52
Guaranteed
5.9257.11
7.128.5
10.1511.7
12.7513.25
14.2515.35
17.719.7
21.323.6
24.2527.5
27.529.5
31.833.4
37.040.0
51.452.6
N/A
N/A
N type N type
or
or
PDR 70 PDR 84
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320
N/A
+25
+21
+21
+21
+19
+19
+18
+18
+17
+14.5
6-26G:1.5 dB
28-52G:+1.5/2.5 dB
0 to 6 dB
1.0 dB
0 to 6 dB
0 to 28 dB
ATPC (1 dB step)
0 to 28 dB
Threshold Level
28 (27.5)
75.5
74.5
10 ppm
+3.0 dB
74.5
75
75
74.5
74.5
73
73
73
69.5
*1 MHz
Above value 1.5 dB
System Gain
*1
100.5
95.5
95.5
96
94
94
92.5
92.5
-6
92.5
3.0 dB
90
87.5
66.5
MHz
Above value +1.5 dB
BER = 10-3
20
-12
Less than 10
Residual BER
2-24
*3
-6
(dBm), (Measured at ODU input port) at BER = 10
BER = 10-3
28 (27.5)
*3
6 ppm
Frequency Stability
NEC Original
at RSL=30 dBm
*1
*2
*3
ROI-S05748
Interface
type
Direct
Mount
Remote
mount
*2
7-8
10-11
13
15
18
23
26
28
32
38
Guaranteed
5.9257.11
7.128.5
10.1511.7
12.7513.25
14.2515.35
17.719.7
21.323.6
24.2527.5
27.529.5
31.833.4
37.040.0
N/A
N/A
PDR
100
PBR
120
PBR
140
PBR
220
PBR
220
PBR
260
PBR
320
PBR
320
PBR
320
+25
+21
+21
+21
+19
+19
+18
+18
+17
+14.5 6-26G:1.5 dB
28-38G:+1.5/2.5 dB
*3
0 to 25 dB
ATPC range)
0 to 25 dB
Threshold Level
*1
69.5
*4
1.0 dB
*4
0 to 20 dB
*3
0 to 20 dB
6 ppm
10 ppm
-6
(dBm), (Measured at ODU input port) at BER = 10
+3.0 dB
Frequency Stability
28 (27.5)
N type N type
or
or
PDR 70 PDR 84
NEC Original
68.5
68.5
69
69
69
68.5
68.5
67
67
MHz
Above value 1.5 dB
BER = 10-3
System Gain
Channel Separation =
89.5
89.5
90
88
88
86.5
-6
3.0 dB
86.5
84
81.5
*1 MHz
28 (27.5)
BER = 10-3
20
Less than 10
-12
at RSL=30 dBm
*1
*2
*3
*4
2-25
ROI-S05748
Item
PDH
1
2
3
IDU type
Modulation Type
Baseband Interface
Channel Number
Total Capacity
4
5
6
SDH
LAN
1+0 Expandable/1+1
QPSK/16/32QAM
128QAM
QPSK/16/32/128QAM
E3:
155.52 Mbps 20 ppm 10/100 Base-T(X)
E1:
1000 Base-SX
2.048 Mbps 50 ppm 34.368 Mbps 20 ppm
1000 Base-T
75 ohm/120 ohm
75 ohm
75 ohm/S-1.1/L-1.1
D-sub37/MDR68 IEC 169-29 (1.0/2.3) IEC 169-29 (1.0/2.3) RJ-45 (10/100/1000 Base-T(X))
LC (1000 Base-SX)
5/10/16/20/40/48
1/2
1/2*
1/2
10/20/32/40/80/96
34/68 Mbps
155 Mbps
10/20/40/80/100/100+50,
Mbps
75+75 Mbps
V.11 (Contra/Co-directional) 2 channels, RS-232C 2 channels
IDU-IDU
See table below
Service Channels
EOW
External alarm &
House keeping
7 Security level by LCT
2 levels
8 Control &Setting by
Serial Interface (USB connector)
LCT/PNMT
Loop Back
a) Far End Baseband Loop Back
b) Near End Baseband Loop Back
c) IF Loop back
BER Alarm
Adjustable 10-3/ 10-4/ 10-5 (High BER) 10-6/ 10-7/ 10-8/ 10-9 (Low BER)
Frequency setting
Direct entry or Table Download entry: Available when using PNMx (optional)
TX output Control
Manual control, Automatic control, Mute control
9 Performance
PMON Items;
monitoring (PMON) a) OFS, b) BBE, c) ES, d) SES, e) SEP, f) UAS
/Metering
Metering Items
a) Output power level (TX PWR), b) Received signal level (AGC V) c) Bit error rate (BER MON)
LAN monitoring Items;
a) RX Unicast, b) RX Broadcast, c) RX Multicast, d) RX Pause, e) RX CRC error
10 LED Display
CTRL
IDU Alarm (Red)
Maintenance (Amber)
Memory Access (Amber)
MODEM
Operating PWR (Green)
ODU Alarm (Red)
MD/CBL Alarm (Red)
TX status (Green)
RX status (Green)
XPIC Reset (Amber)*
PDH INTFC
Module alarm (Red)
SDH INTFC
Module alarm (Red)
Online (Green)**
LAN/WS INTFC
Module alarm (Red)
2-26
ROI-S05748
Alarm Item
displayed
on LCT/PNMT
MAINT
IDU CPU ALM
PS ALM1
PS ALM2
ODU ALM1
ODU ALM2
ODU CPU/CBL
OPN ALM1
Condition
ALM LED
Indication
(IDUs front)
MAINT
PWR
ODU
RL2
RL3
RL4
RL5
RL6
2-27
ROI-S05748
Alarm Item
displayed
on LCT/PNMT
33 CH USAGE ERROR
CH 1-48
Condition
ALM LED
Indication
(IDUs front)
IDU INTFC
<Note7>
IDU INTFC
IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note9>
IDU INTFC
<Note9>
IDU INTFC
<Note9>
IDU INTFC
<Note9>
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
44 HK-OUT1
45 HK-OUT2
46 HK-OUT3
47 HK-OUT4
41 XCTRL ALM2
42 XREF ALM1
43 XREF ALM2
RL2
RL3
RL4
RL5
RL6
2-28
ROI-S05748
Relay
Event/ Alarm Open
(Normally closed)
HK-IN1
HK-IN2
HK-IN3
HK-IN4
HK-IN5
HK-IN6
Cluster ALM input1
Cluster ALM input2
Cluster ALM input3
Cluster ALM input4
Condition
Event Indication
IN5
IN6
+3.3 V
Normally Open
Control Closed
2-29
ROI-S05748
Item
Specification
Interconnection
Signals
150 m (5D-FB)
300 m (8D-FB)
350 m (10D-FB)
Cable Equalization
2-30
ROI-S05748
11 - 52 GHz Hybrid
Frequency
Range
[GHz]
5.925
6.43
7.125
7.7
10.5
12.75
14.5
17.7
21.2
24.5
31.8
37
51.4
6.425
7.11
7.9
8.5
11.7
13.25
15.35
19.7
23.6
26.5
33.4
39.5
52.6
1-2 PORT
Variation
Max.(dB)
Loss Max.
(dB)
Isolation
Min.(dB)
VSWR Max.
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
3.7
3.7
3.7
3.7
3.5
3.5
3.5
3.5
3.5
3.8
3.8
3.8
4.5
20
20
20
20
20
20
20
20
20
20
20
20
20
1.3
1.3
1.3
1.3
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3
Interface
(ANT Side) (ODU Side)
UDR70
UDR70
UDR84
UDR84
N Connector
N Connector
N Connector
N Connector
NEC
original
NEC
original
2-31
ROI-S05748
2.4.1 10 dB Coupler
There are two types of NEC 10 dB Coupler; one is coaxial cable
connection type for 6/7/8 GHz bands and the other is ODU Direct Mount
type for 11 - 38 GHz Bands. The following 10 dB Coupler is suited for
Andrew or RFS Antenna, and all NEC ODUs.
11 - 38 GHz Coupler
Frequency
Range
[GHz]
5.925 - 7.125
7.125 - 8.5
Loss Max.
(dB)
Isolation
Min.(dB)
VSWR Max.
(ANT Side)
(ODU Side)
0.5
1.2
20
1.3
UDR70
N Connector
UDR84
N Connector
NEC original
NEC original
0.5
1.2
20
1.3
0.5
1.2
20
1.2
11
10.5 - 11.7
13
12.75 - 13.25
0.5
1.2
20
1.2
15
14.5 - 15.35
0.5
1.2
20
1.2
18
17.7 - 19.7
0.5
1.2
20
1.2
23
21.2 - 23.6
0.5
1.2
20
1.2
26
24.5 - 26.5
0.5
1.2
20
1.2
32
31.8 - 33.4
0.5
1.2
20
1.2
38
37 - 39.5
0.5
1.2
20
1.2
2-32
Interface
1-2 PORT
Variation
Max.(dB)
ROI-S05748
Frequency
Range
[GHz]
XPD Min.
[dB]
LOSS Max.
[dB]
P-P
ISOLATION
Min.[dB]
VSWR Max.
INTERFACE WG
(ODU
INNER DIA. (mm) INTERFACE
Side)
(ANT Side)
11
10.5 - 11.7
35
0.6
38
1.3
18.0
13
12.75 - 13.25
35
0.6
38
1.3
15.0
15
14.5 - 15.35
35
0.6
38
1.3
13.5
18
17.7 - 19.7
35
0.6
38
1.3
10.5
23
21.2 - 23.6
35
0.6
38
1.3
9.0
26
24.5 - 26.5
35
0.8
38
1.3
8.0
32
31.8 - 33.4
35
1.0
38
1.3
6.5
38
37 - 39.5
35
1.0
38
1.3
5.5
NEC original
2-33
ROI-S05748
2-34
L6 GHz
: 5.925 - 6.425
U6 GHz
7 GHz
: 6.43 - 7.11
: 7.125 - 7.9
8 GHz
: 7.7
10-11 GHz
13 GHz
15 GHz
: 10.15 - 11.7
: 12.75 - 13.25
: 14.5 - 15.35
18 GHz
: 17.7
- 19.7
23 GHz
: 21.2
- 23.6
26 GHz
: 24.5
- 26.5
28 GHz
32 GHz
38 GHz
: 27.5
: 31.8
: 37
- 29.5
- 33.4
- 39.5
52 GHz
: 51.4
- 52.6
- 8.5
252.04/
266
340
154/
161/
196/
245
119/
126/
151.614/
154/
266/
294.44/
305.56/
311.32
530
266
315/
420/
470/
490/
644/
728
340/
750/
1008/
1010/
1092.5/
1120/
1250/
1560
600/
1008/
1200/
1232
855/
1008/
1123.5
1008
812
700/
1000/
1260/
616
ROI-S05748
*2
The DC V to the ODU is supplied through the coaxial cable which is also
used for the IF and other signals. The PS circuit on the ODU produces +7/
+8/+9/7/8/9 * and 15 V DC for the component modules from the 48
V DC supplied from the IDU.
Note: *: Necessary voltages in the ODU vary depending on the ODU
type.
IDU
ODU (NEO)
MODEM
ODU INTFC
TX IF
RX IF
SV/CTRL
48 V
SEP/
COMB
FIL
48 V
DC
INPUT
48 V
G
SEL V
(2/4)
(1/3)
SV/CTRL
PS
PWR
FUSE
DC-DC
CONV
TX IF
RX IF
SEP/
COMB
FIL
15 V
7/8/9 V *1
+7/+8/+9 V *1
+3.6 V
48 V
*2
CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC, E3
INTFC, LAN/WS INTFC, GbE INTFC,
Notes:
2-35
ROI-S05748
IDU
MODEM
ODU (NEO)
ODU INTFC
TX IF
RX IF
SV/CTRL
48 V
SEP/
COMB
FIL
48 V
DC
INPUT
48 V
SEL V
(2/4)
SV/CTRL
DC-DC
CONV
FUSE
15 V
7/8/9 V *1
+7/+8/+9 V *1
PS
PWR
(1/3)
TX IF
RX IF
SEP/
COMB
FIL
+3.6 V
48 V
*2
CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC,
E3 INTFC, LAN/WS INTFC, GbE INTFC,
DC
INPUT
48 V
G
SEL V
(2/4)
PWR
FUSE
(1/3)
DC-DC
CONV
+3.6 V
ODU (NEO)
TX IF
RX IF
SV/CTRL
SEP/
COMB
FIL
48 V
SEP/
COMB
FIL
48 V
MODEM
SV/CTRL
ODU INTFC
PS
48 V
Notes:
2-36
TX IF
RX IF
15 V
7/8/9 V *1
+7/+8/+9 V *1
ROI-S05748
IDU
20 to 60 V/
+20 to +60 V
()
DC
INPUT (+)
SEL V
(2/4)
PWR
ODU INTFC
FUSE
(1/3)
TX IF
RX IF
SV/CTRL
FUSE
(2) 43 V
DC-DC
CONV
(1) G
OUT
43 V
SEP/
COMB
FIL
SEP/
COMB
FIL
43 V
SV/CTRL
DC-DC CONV *2
SEL V
(2/4)
(1/3)
PS
PWR
DC-DC
CONV
FUSE
TX IF
RX IF
15 V
7/8/9 V *1
+7/+8/+9 V *1
+3.6 V
43 V
MODEM
*2
CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC,
E3 INTFC, LAN/WS INTFC, GbE INTFC
Notes:
2-37
2-38
38 pages
ROI-S05748