You are on page 1of 42

CONTENTS

ROI-S05748-056E
April, 2006

PASOLINK NEO
6-52 GHz PDH/SDH DIGITAL RADIO SYSTEM

Section I DESCRIPTION
CONTENTS
TITLE

PAGE

GENERAL DESCRIPTION 1-1

SYSTEM CONFIGURATION AND CHARACTERISTICS 2-1

2.1

System Configuration 2-1

2.2

Performance Characteristics 2-15

2.2.1

General System 2-15

2.2.2

LAN Interface (10/100 Base-T(X)) 2-17

2.2.3

LAN Interface (GbE) 2-19

2.2.4

Service Channel (SC) 2-20

2.2.5

LCT (PNMT) Interface 2-20

2.2.6

PNMS Interface 2-20

2.2.7

ODU (Outdoor Unit) and System performance 2-22

2.2.8

IDU (Indoor Unit) and System performance 2-26

2.3 Interconnection between ODU and IDU 2-30


2.4

Hybrid Combiner/Divider 2-31

2.4.1

10 dB Coupler 2-32

2.4.2

OMT (Ortho-Mode Transducer) 2-33

2.5

RF Channel Plan 2-34

2.6

Power Supply 2-35

CL-1

CONTENTS

ROI-S05748

(This page is intentionally left blank.)

CL-2
2 pages

GENERAL DESCRIPTION

ROI-S05748

1. GENERAL DESCRIPTION
This section provides descriptive information on the PASOLINK NEO
radios which are used for the wide/narrow band point-to-point digital
microwave radio links.
The Indoor Unit (IDU) provides digital PDH (5-48 E1, 1/2 E3), SDH
(1/2 STM-1) and LAN (2 10/100Base-TX) signal transmission by the
change of the data signal interface card. It can select the modulation
method QPSK/16QAM/32QAM/128QAM, by software selection
depending on the transmission capacity that is configured in the
modulator/demodulator unit.
The Outdoor Unit (ODU) can be applied for a wide range of RF frequency
bands from 6/7/8/10/11/13/15/18/23/26/32/38/52 GHz.
Applications using the following redundancy configurations, Unprotected
(1+0), 2 (1+0)* and Protected (1+1), 2 (1+1)* are available for
PASOLINK NEO radio systems.
Note: * XPIC
Cross Polarization Interference Canceller (XPIC) system is applied for
dual polarized systems using the same frequency in 2 (1+0) and 2
(1+1) configurations.

1-1

GENERAL DESCRIPTION

ROI-S05748

PASOLINK NEO

0678
IDU Package Label

0678

PASOLINK NEO
MDP-150MB-1AA INDOOR UNIT

PASOLINK NEO
MDP-150MB-1AA INDOOR UNIT

1+0
1+1
XPIC
ETSI (RACK)
LABEL( EN
FR
ES
DE
IT)
INTFC(1)
STM1-E
STM1-0
LAN/WS GbE
16E1(
)
48E1 OTHER(
)
INTFC(2)
STM1-0
LAN/WS OTHER(
)

1+0
1+1
XPIC
ETSI (RACK)
LABEL( EN
FR
ES
DE
IT)
INTFC(1)
STM1-E
STM1-0
LAN/WS GbE
16E1(
)
48E1 OTHER(
)
INTFC(2)
STM1-0
LAN/WS OTHER(
)

MADE IN JAPAN

NWM-001846-001

MODEM(1)

MDP-150MB-1AA
INDOOR UNIT

INTFC (2)

INTFC (1)

MADE IN JAPAN

NWM-001846-001

SER. No.

IDU Name Plate

0678
(H2930)

DATE

WEIGHT: 4 kg (WITH OPTION)

CTRL

MODEM(2)

48 V

2.5A (WITH ODU & OPTION)

NEC Corporation TOKYO JAPAN


! IF IN/OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

G PULL
ALM
PWR

2M IN/OUT-B

2M IN/OUT-A

PORT 1

PROTECT

PORT 2

(Blank)
LCT

NMS

NE

100M

100M

XIF IN XIF OUT

MADE IN JAPAN

PASOLINK NEO
MAINT
MEMORY
IDU

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

IDU 1+0
! IF IN/OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

G PULL

! IF IN/OUT

ALM
PWR

2M IN/OUT-B

2M IN/OUT-A

100M

PORT 1

PORT 2

XIF IN XIF OUT

PROTECT

PULL
PWR

LCT

NMS

NE

SC IN/OUT

ODU Name Plate

SERIAL No.

PASOLINK NEO

0678

TRP-( )G-1B
OUTDOOR UNIT (NHG)
SHIFT FREQUENCY

(NWA-009034)

MHz SUB BAND

TX
HIGH/LOW

EOW

CALL

CAUTION
Non-ionizing
radiation

(NWA-009034)

MHz SUB BAND


MHz

TX FREQUENCY

SERIAL No.

-48V INPUT

CAUTION

Power down IDU before


disconnection or
connection of cable.

Non-ionizing
radiation

ODU

IFL

TX
HIGH/LOW

DATE

WEIGHT 3.5kg/ - 48V


0.5A
NEC Corporation TOKYO JAPAN

MADE IN JAPAN

RX LEV
MON

1-2
2 pages

0678

TRP-( )G-1B
OUTDOOR UNIT (NHG)
SHIFT FREQUENCY

DATE

WEIGHT 3.5kg/ - 48V


0.5A
NEC Corporation TOKYO JAPAN

PASOLINK NEO
MAINT
MEMORY
IDU

AUX/ALM

IDU 1+1
PASOLINK NEO

100M

FG

MADE IN JAPAN

-48V INPUT
Power down IDU before
disconnection or
connection of cable.

MMC

XPIC CTRL

PWR
ODU
MD/
CBL SELV

XIF IN XIF OUT

TX
RX
XPIC
RESET

ROI-S05748

SYSTEM CONFIGURATION AND CHARACTERISTICS

2. SYSTEM CONFIGURATION AND


CHARACTERISTICS
This section provides outline of the system configuration, system
performance, RF channel plan, external alarm items and House keeping
input/output, and power supply.

2.1 System Configuration


The system consists of the MDP-150MB-1AA Modulator-Demodulator
(Indoor Unit (IDU)) and TRP-(*1)G-1B Transmitter-Receiver (Outdoor
Unit (ODU)), Hybrid Combiner/Devider*2 or Orthogonal Mode
Transducer (OMT)*3 and the antenna.
The TRP-( )G-1B is available with frequency bands of 6 GHz to 52 GHz.
band.
Notes:

*1:ODU Type depends on the frequency band used, such as


TRP-(13)G-1B is applied for 13 GHz band.
*2:The Combiner/Divider is used in (1+1) single antenna
configuration for antenna direct mount type ODUs.
*3:The OMT is used in XPIC systems with antenna direct
mounting ODUs.

Refer to
Fig. 2-1
Fig. 2-2
Fig. 2-3
Fig. 2-4
Fig. 2-5
Fig. 2-6
Fig. 2-7
Fig. 2-8
Fig. 2-9

Protected/Unprotected System Configuration (1/2)


Signal Interface/Capacity (1/2)
IDU e/w Standard and Optional Interface (1/2)
Configuration of the ODU (1/3)
System Block Diagram (1/4)
Hybrid
10 dB Coupler
OMT Transducer
Power Supply System Block Diagram (1/3)

Table 2-1 System General Performance (1/2)


Table 2-12 System Performance for IDU
Table 2-13 Alarm & House Keeping Output Items
Table 2-14 House keeping input Items
Table 2-16 Characteristics
Table 2-17 Characteristics
Table 2-18 Characteristics
Table 2-19 RF Frequencies

2-1

SYSTEM CONFIGURATION AND CHARACTERISTICS

RF Cable

1+0 IDU
DATA
IN/OUT

RF Cable

f1

IF Cable

IDU

f1

ROI-S05748

ODU

ODU

1+0 IDU
IF Cable

IDU

DATA
IN/OUT

1+0 with Waveguide/Coaxial Cable Connection


1+0 IDU
DATA
IN/OUT

1+0 IDU
f1

IF Cable

IDU

ODU

ODU

f1

IF Cable

IDU

DATA
IN/OUT

1+0 with Antenna Direct Connection


1+1 IDU

1+1 IDU
IF Cable

ODU (Working)

No.1
DATA
IN/OUT

RF Cable

f1

HYB

ODU (Working)
HYB

IF Cable
No.1
RF Cable

f1

No.2
IF Cable

ODU (Standby)

No.2
ODU (Standby)

DATA
IN/OUT

IF Cable

1+1HS/HS with Coaxial Cable Connection


1+1 IDU

1+1 IDU
IF Cable

No.1
DATA
IN/OUT

ODU (Working)
HYB

No.2
IF Cable

f1
f1

ODU (Standby)

ODU (Working)

IF Cable
No.1

HYB
ODU (Standby)

No.2

DATA
IN/OUT

IF Cable

1+1 HS/HS with Antenna Direct Connection


1+1 IDU

1+1 IDU
IF Cable

No.1
DATA
IN/OUT

ODU (Working)
HYB

No.2
IF Cable

f1
f1
f1

ODU (Standby)

ODU (Working)

IF Cable
No.1
IF Cable

No.2

DATA
IN/OUT

ODU (Standby)

1+1 HS/Hybrid SD with Antenna Direct Connection


1+1 IDU
IF Cable
No.1
DATA
IN/OUT

No.2

ODU (Working)

f1
f1

1+1 IDU
ODU (Working)

IF Cable
No.1
IF Cable

IF Cable
ODU (Standby)

No.2

DATA
IN/OUT

ODU (Standby)

1+1 HS SD with Antenna Direct Connection


1+1 IDU

1+1 IDU
IF Cable

No.1
DATA
IN/OUT

ODU (Working)
HYB

No.2
IF Cable

ODU (Working)

f1
f2
f1
f2

ODU (Working)

IF Cable
No.1

HYB
ODU (Working)

No.2
IF Cable

1+1 Twin-path FD with Antenna Direct Connection

Fig. 2-1 Protected/Unprotected System Configuration (1/2)

2-2

DATA
IN/OUT

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

1+0 IDU
DATA1
IN/OUT
IDU XPIC
CTRL
Cable
DATA2
IN/OUT

IDU
IDU
X IF Cable

1+0 IDU
IF Cable

ODU (Working)

V (H)

OMT
IF Cable

ODU (Working) H (V)

f1
f1
f1
f1

V (H)

IF Cable

ODU (Working)

IDU

IDU XPIC
IDU
X IF Cable CTRL
Cable

OMT
H (V) ODU (Working)

DATA1
IN/OUT

IF Cable

IDU

IDU

1+0 IDU

1+0 IDU

DATA2
IN/OUT

2(1+0) XPIC with Antenna Direct Connection


1+0 IDU
DATA1
IN/OUT

ODU (Working) V (H)

f1
f1
f1
f1

RF Cable

IDU XPIC
IDU
CTRL
X IF Cable
Cable
DATA2
IN/OUT

1+0 IDU
IF Cable

IDU

IF Cable

ODU (Working) H (V)

IF Cable

V (H) ODU (Working)

IDU

RF Cable
H (V) ODU (Working)

DATA1
IN/OUT

IDU
IDU XPIC
X IF Cable CTRL
Cable

IF Cable

IDU

IDU

1+0 IDU

1+0 IDU

DATA2
IN/OUT

2(1+0) XPIC with Waveguide/Coaxial Cable Connection

1+0 IDU
DATA1
IN/OUT

1+0 IDU
IF Cable

IDU

ODU (Working) V (H)

IDU XPIC
IDU
CTRL
X IF Cable
Cable

OMT
IF Cable

DATA2
IN/OUT

f1
f1
f1
f1

ODU (Working) H (V)

V (H) ODU (Working)

IF Cable

IDU

OMT
H (V) ODU (Working)

IDU
IDU XPIC
X IF Cable CTRL
Cable
DATA2
IDU
IN/OUT

IF Cable

IDU
1+0 IDU

DATA1
IN/OUT

1+0 IDU

2(1+0) XPIC with Waveguide/Coaxial Cable Connection


1+1 IDU
IF Cable
No.1
DATA1
IN/OUT
IDU XPIC
CTRL
Cable

HYB
No.2

ODU (Standby)
V (H)
No. 1

IDU
X IF Cable

H (V)

No. 2
No.1

DATA2
IN/OUT

V (H)

No. 1

ODU (Working)

ODU (Working)
HYB

No.2
IF Cable
1+1 IDU

ODU (Standby)
No. 2

H (V)

V (H)
f1
f1
f1
f1

No. 1

ODU (Working)

1+1 IDU
IF Cable
No.1

HYB
No.2

ODU (Standby)
V (H)

No. 1

H (V)

No. 2

IDU
X IF Cable

HYB
ODU (Standby)
No. 2

IDU XPIC
CTRL
Cable

No.1

ODU (Working)

H (V)

DATA1
IN/OUT

No.2

DATA2
IN/OUT

IF Cable
1+1 IDU

2(1+1) XPIC with Waveguide/Coaxial Cable Connection

Fig. 2-1 Protected/Unprotected System Configuration (2/2)

2-3

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

IDU

MAIN DATA INTFC (Selectable)


16E1 (5/10/16 2 MB) G.703
16E1 (0 to 16 2 MB G.703 + 40 to 8 MB 10/100base T(x)
IEEE 802.3)

QPSK/16QAM

E3 (1/2 34 MB + 4/8 2 MB) G.703


48E1 (5/10/20/40/48 2 MB) G.703

QPSK/16QAM/32QAM

STM-1 (155 MB ELE) G.703


STM-1 (155 MB OPT) G.957, S-1.1/L-1.1

128QAM

10/100 Base T(X) 2-Port LAN IEEE802.3


6 to 52 GHz

1000 Base T/SX IEEE 802.3z


MAIN DATA INTFC (for APS)
STM-1 (155 MB OPT) ITU-T G.957, S-1.1/L-1.1

ODU
128QAM

WS/LAN INTFC (Additional)


WS (1 2 MB) + 64/128/192/256 KB SC- LAN

128QAM

ALM/HK/SC (AUX) INTFC


SC (2 64 KB V.11 + 2 9.6 KB RS-232C) +
EOW (1 )

QPSK/16/32/128QAM

6 ALM OUT (4 HK OUT/4 Cluster OUT)

QPSK/16/32/128QAM

6 HK IN/4 Cluster IN

QPSK/16/32/128QAM

1+0/1+1 Configuration
Fig. 2-2 Signal Interface/Capacity (1/2)

2-4

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

MAIN DATA INTFC (Selectable)

IDU

STM-1 (155 MB ELE) G.703


STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
10/100 Base T(X) 2-Port LAN IEEE 802.3
1000 Base T/SX IEEE 802.3z
MAIN DATA INTFC (for APS)
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1

No.1
128QAM

WS/SC-LAN INTFC (Additional)


WS (1 2 MB) + 64/128/192/256 KB SC- LAN
ALM/HK/SC(AUX)
SC (2 64 KB V.11 + 2 9.6 KB RS-232C) +
EOW (1 )

6 to 52 GHz

6 ALM OUT (4 HK OUT/4 Cluster OUT)

ODU

6 HK IN/4 Cluster IN

OMT

MAIN DATA INTFC (Selectable)

IDU

ODU

STM-1 (155 MB ELE) G.703


STM-1 (155 MB OPT) G.957, S-1.1/L-1.1
10/100 Base T(X) 2-Port LAN
1000 Base T/SX IEEE 802.3z
MAIN DATA INTFC (for APS)
STM-1 (155 MB OPT) G.957, S-1.1/L-1.1

No.2
128QAM

WS/SC-LAN INTFC (Additional)


WS (1 2 MB) + 64/128/192/256 KB SC- LAN
ALM/HK/SC(AUX)
SC (2 64 KB V.11 + 2 64 KB RS-232C) +
EOW (1 )
6 ALM OUT (4 HK OUT/4 Cluster OUT)
6 HK IN/4 Cluster IN

XPIC Configuration
Fig. 2-2 Signal Interface/Capacity (2/2)

2-5

SYSTEM CONFIGURATION AND CHARACTERISTICS

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

ROI-S05748

PULL

(Blank)

ALM
PWR

STM-1 IN

STM-1 OUT

PROTECT

(Blank)

LCT

NMS

NE

PASOLINK NEO
MAINT
MEMORY
IDU

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

Equipped with STM-1 Electrical Interface


! IF IN/OUT

XIF IN XIF OUT

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL
ALM
PWR

STM-1 IN

STM-1 OUT

ALM
STM-1 OUT

ONLINE

STM-1 IN

PROTECT

PASOLINK NEO
MAINT
MEMORY
IDU

(Blank)
LCT

NMS

NE

ONLINE

XPIC CTRL

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

Equipped with STM-1 Optical Interface for APS


! IF IN/OUT

XIF IN XIF OUT

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

G PULL
ALM
2M IN/OUT-B

2M IN/OUT-A

PWR

PORT 1

PROTECT

(Blank)
LCT

NMS

NE

PORT 2

100M

100M

XPIC CTRL

PASOLINK NEO
MAINT
MEMORY
IDU

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

Equipped with 16E1 Interface with 2 Port LAN


! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL
ALM
2M IN/OUT-B

2M IN/OUT-A

PWR

2M IN/OUT-C

PROTECT

PASOLINK NEO
MAINT
MEMORY
IDU

(Blank)
LCT

NMS

NE

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

Equipped with 48E1 Interface


! IF IN/OUT

XIF IN XIF OUT

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL

E3 CH1

E3 CH2
ALM

PWR

IN

IN

WS IN/OUT

OUT

100M

PORT 1

PROTECT

PORT 2

PASOLINK NEO
MAINT
MEMORY
IDU

(Blank)
LCT

NMS

NE

100M

OUT

XPIC CTRL

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

Equipped with E3 Interface


! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL

(Blank)

ALM
PWR

STM-1 IN

STM-1 OUT

PROTECT

PASOLINK NEO
MAINT
MEMORY
IDU

(Blank)
LCT

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

NMS

NE

AUX/ALM

SC IN/OUT

PULL

STM-1 IN

CALL

MMC

(Blank)

ALM
PWR

EOW

STM-1 OUT

PROTECT

PASOLINK NEO
MAINT
MEMORY
IDU

(Blank)
LCT

NMS

NE

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

Equipped with STM-1 Electrical Interface in XPIC


! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL

(Blank)

ALM
PWR

STM-1 IN

STM-1 OUT

43V

STD

G
OUT

PWR
ALM

FUSE (250V/8AH)

SELV

PROTECT

PULL
PWR

LCT

NMS

NE

AUX/ALM

EOW

Equipped with DC-DC CONV

Unprotected System (IDU)


Fig. 2-3 IDU e/w Standard and Optional Interface (1/2)

2-6

PASOLINK NEO
MAINT
MEMORY
IDU

SC IN/OUT

CALL

MMC

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

! IF IN/OUT

XIF IN XIF OUT

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

XPIC CTRL

PULL

(Blank)

ALM
PWR

STM-1 IN

STM-1 OUT

! IF IN/OUT

XIF IN XIF OUT

PROTECT

PULL
PWR

LCT

NMS

NE

AUX/ALM

SC IN/OUT

PASOLINK NEO
MAINT
MEMORY
IDU

EOW

CALL

MMC

Equipped with STM-1 Electrical Interface


! IF IN/OUT

XPIC CTRL

TX
RX
XPIC
RESET

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

! IF IN/OUT

XIF IN XIF OUT

PWR
ODU
MD/
CBL SELV

PULL
ALM
PWR

STM-1 OUT

STM-1 IN

ALM
STM-1 OUT

ONLINE

PWR

STM-1 IN

PROTECT

PULL

LCT

NMS

NE

AUX/ALM

SC IN/OUT

ONLINE

XIF IN XIF OUT

PASOLINK NEO
MAINT
MEMORY
IDU

EOW

CALL

MMC

Equipped with STM-1 Optical Interface in APS


! IF IN/OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

G PULL
ALM
PWR

2M IN/OUT-B

2M IN/OUT-A

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PORT 1

PROTECT

PULL

PORT 2

PWR

LCT

NMS

NE

100M

100M

XIF IN XIF OUT

PASOLINK NEO
MAINT
MEMORY
IDU

AUX/ALM

SC IN/OUT

EOW

CALL

MMC

Equipped with 16E1 Interface with 2 Port LAN


! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL
ALM
2M IN/OUT-B

2M IN/OUT-A

PWR

2M IN/OUT-C

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PROTECT

PULL
PWR

LCT

NMS

NE

AUX/ALM

SC IN/OUT

PASOLINK NEO
MAINT
MEMORY
IDU

EOW

CALL

MMC

Equipped with 48E1 Interface


! IF IN/OUT

XIF IN XIF OUT

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL

E3 CH1

IN

OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

IN

WS IN/OUT

OUT

PWR

100M

PORT 1

PROTECT

PULL

LCT

NMS

NE

AUX/ALM

SC IN/OUT

EOW

CALL

PORT 2

100M

! IF IN/OUT

E3 CH2
ALM

PWR

XPIC CTRL

PASOLINK NEO
MAINT
MEMORY
IDU
MMC

Equipped with E3 Interface


! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

PULL

(Blank)

ALM
PWR

STM-1 IN

STM-1 OUT

! IF IN/OUT

XIF IN XIF OUT

XPIC CTRL

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

TX
RX
XPIC
RESET

PWR
ODU
MD/
CBL SELV

XPIC CTRL

PWR
ODU
MD/
CBL SELV

XPIC CTRL

TX
RX
XPIC
RESET

! IF IN/OUT

XIF IN XIF OUT

PROTECT

PULL
PWR

LCT

NMS

NE

AUX/ALM

SC IN/OUT

PASOLINK NEO
MAINT
MEMORY
IDU

EOW

CALL

MMC

PULL

(Blank)

ALM
PWR

STM-1 IN

STM-1 OUT

! IF IN/OUT

XIF IN XIF OUT

PROTECT

PULL
PWR

LCT

NMS

NE

AUX/ALM

SC IN/OUT

PASOLINK NEO
MAINT
MEMORY
IDU

EOW

CALL

MMC

Equipped with STM-1 Electrical Interface in XPIC

Protected System (IDU)

Fig. 2-3 IDU e/w Standard and Optional Interface (2/2)

2-7

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

ODU

ODU

Waveguide Connection (1+0)

Coaxial Cable Connection 6/7/8GHz (1+0)

ODU

Antenna
ODU

OMT
Antenna Direct Mounting 2(1+0)
Dual Pol. Antenna

OMT

Antenna Direct Mounting (1+0)

Dual Pol. Antenna

ODU

ODU

Dual Pol. Antenna

Waveguide Connection 2(1+0)

Coaxial Cable Connection 6/7/8GH 2(1+0)

Fig. 2-4 Configuration of the ODU (1/3)

2-8

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

ODU

HYB

ODU
ODU

Coaxial Cable Connection 6/7/8 GHz (1+1)

Waveguide Connection (1+1 SD)

ODU

HYB
Antenna Direct Mounting (1+1)

Fig. 2-4 Configuration of the ODU (2/3)

2-9

SYSTEM CONFIGURATION AND CHARACTERISTICS

ODU

ODU

Dual Pol. Antenna

ODU

ODU

Dual Pol. Antenna

Waveguide Connection 2(1+1) XPIC SD

Fig. 2-4 Configuration of the ODU (3/3)

2-10

ROI-S05748

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

6 to 52 GHz

16E1+2PORT LAN/
48E1/
1/2E3

fL(H)

ODU

IDU
MODEM
( )INTFC *

QPSK/
16QAM/
32QAM/
MODEM

DPU/
FEC

IN/OUT

fH(L)
ODU
INTFC

BPF
(TX)

ODU
INTFC
RF
CKT

LPF/EQL

BPF
(RX)

ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW

DC-DC
CONV

CTRL

SYNTH
(LO)

PS

EOW
(JACK)

CTRL

PS IN

Note: * Optional
1+0 CONFIGURATION FOR PDH
6 to 52 GHz
IDU
STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE

MODEM
( )INTFC *1

IN/OUT

STM-1 (OPT)

fL(H)

ODU

DPU/
FEC

128QAM
MODEM

fH(L)
ODU
INTFC

RF
CKT

LPF/EQL

( )INTFC *2

BPF
(TX)

ODU
INTFC

DC-DC
CONV
SYNTH
(LO)

PS
WS/SC-LAN

BPF
(RX)

LAN/WS INTFC *3
CTRL

ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW

CTRL

EOW
(JACK)
PS IN

Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals

1+0 CONFIGURATION FOR SDH


Fig. 2-5 System Block Diagram (1/4)

2-11

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

ODU

IDU

HYB

MODEM

16E1+2PORT LAN/
48E1/
1/2E3

DPU/
FEC

( )INTFC *

IN/OUT

QPSK/
16QAM/
32QAM/
MODEM

ODU
INTFC

BPF
(TX)

ODU
INTFC
RF
CKT

BPF
(RX)

LPF/EQL
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW

DC-DC
CONV

CTRL

SYNTH
(LO)

PS

EOW
(JACK)

6 to 52 GHz

CTRL

fL(H)

PS IN
ODU

fH(L)
MODEM
DPU/
FEC

QPSK/
16QAM/
32QAM/
MODEM

ODU
INTFC

BPF
(TX)

ODU
INTFC
RF
CKT

BPF
(RX)

LPF/EQL
DC-DC
CONV
SYNTH
(LO)

PS
PS IN
CTRL

Note:

* :Optional

1+1 CONFIGURATION FOR PDH

Fig. 2-5 System Block Diagram (2/4)

2-12

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

ODU

IDU
STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE
IN/OUT

HYB

MODEM
( )INTFC *1

DPU/
FEC

128QAM/
MODEM

ODU
INTFC

BPF
(TX)

ODU
INTFC
RF
CKT

BPF
(RX)

LPF/EQL
STM-1 (OPT)

( )INTFC *2
DC-DC
CONV
SYNTH
(LO)

PS
WS/SC-LAN

LAN/WS INTFC *3

6 to 52 GHz

CTRL

fL(H)
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW

fH(L)
CTRL

EOW
(JACK)
PS IN

ODU
MODEM
DPU/
FEC

128QAM/
MODEM

ODU
INTFC

BPF
(TX)

ODU
INTFC
RF
CKT

BPF
(RX)

LPF/EQL
DC-DC
CONV
SYNTH
(LO)

PS
PS IN
CTRL

Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals

1+1 CONFIGURATION FOR SDH

Fig. 2-5 System Block Diagram (3/4)

2-13

SYSTEM CONFIGURATION AND CHARACTERISTICS

ODU

IDU
STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE
IN/OUT

( )INTFC *1

128QAM/
MODEM

ODU
INTFC

BPF
(TX)

ODU
INTFC
RF
CKT

BPF
(RX)

( )INTFC *2
DC-DC
CONV
SYNTH
(LO)

PS
WS/SC-LAN

OMT

MODEM
DPU/
FEC

LPF/EQL
STM-1 (OPT)

ROI-S05748

LAN/WS INTFC *3

6 to 52 GHz

CTRL

fL(H)
ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW

fH(L)
CTRL

EOW
(JACK)
PS IN

IDU

ODU

MODEM

STM-1 (ELE)/
STM-1 (OPT)/
2-PORT LAN/WS
GbE

128QAM/
MODEM

( )INTFC *1

IN/OUT

STM-1 (OPT)

DPU/
FEC

ODU
INTFC

BPF
(TX)

ODU
INTFC
RF
CKT

LPF/EQL

BPF
(RX)

DC-DC
CONV
( )INTFC *2

SYNTH
(LO)

PS

CTRL
WS/SC-LAN

LAN/WS INTFC *3

ALM IN/OUT
SC IN/OUT
NMS
LCT
NE
EOW

CTRL

EOW
(JACK)
PS IN

Notes: *1 :Optional
*2:Provides for APS
*3:Provides for auxiliary signals

1+0 CONFIGURATION FOR XPIC SDH


Fig. 2-5 System Block Diagram (4/4)

2-14

V(H)
H(V)
H(V)
V(H)

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.2 Performance Characteristics


2.2.1 General System
Table 2-1 System General Performance (1/2)
STANDARD (STD)
ITEM

LAN *2

PDH

Capacity

Up to 100 Mbps

Interface

D-sub 37: 16 E1/MDR68: 48E1/


IEC 169-29(1.0/2.3): 1/2E3

Interconnecting Connector, Cable


impedance and Cable length
(IDU-ODU)
Channel Spacing
*1

Environmental
Requirement

QPSK

RJ-45
10/100 Base-T(X)

ODU side: N type female, 50 ohms (Coaxial)


IDU side: TNC type female, 50 ohms (Coaxial)
300m (in case 8D-FB cable or equivalent cable)
7 MHz, 14 (13.75) MHz, 28 (27.5) MHz

16 QAM

3.5 MHz, 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz

32 QAM

28 (27.5) MHz

128 QAM

Not Applicable

Guaranteed
Operation

ODU: 33 to +50C
IDU: 5 to +50C

Workable
Operation

ODU: 40 to +55C
IDU: 10 to +55C

Transportation/
Storage
Relative
humidity

ODU, IDU: 40 to +70C


ODU: 100% applicable
IDU: Less than 90% at +50C (Non-codensing)

EMC

Conforms to EN301 489-4

Safety

Conforms to EN60950
48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2

Power Requirement
Power Consumption (Typical)
ODU/Unit

30 W (6 to 11 GHz), 23 W (13 to 52 GHz)

IDU Card/Unit
MODEM

10 W

48E1 INTFC (for 48 E1)

8W

16E1 INTFC (for 16 E1)

8W

E3 INTFC

8W

CTRL

Mechanical
Dimension

7W
MODEM: 0.5 kg, 48E1 INTFC (for 48 E1): 0.4 kg, 16E1 INTFC (for 16 E1): 0.4 kg,
E3 INTFC (for E3): 0.4 kg, CTRL: 0.4 kg

Weight/Card

ODU

237(W) 237(H) 101(D): Approx. 3.5 kg/Unit

IDU

482(W) 44(H) 240(D): Approx.4 kg

Notes *1: 13.75 or 27.5 MHz is applied for 18 GHz.


*2: For 48E1 INTFC, the LAN is not applicable.

2-15

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

Table 2-1 System Performance Characteristics (2/2)


STANDARD (STD)
ITEM

SDH

LAN

Capacity

155 Mbps *2

Up to 150 Mbps

Interface

Optical: LC
Electrical: IEC 169-29(1.0/2.3)
Up to 2 STM-1 *3

RJ-45
10/100/1000 Base-T(X)
LC: 1000 Base-SX

Interconnecting Connector, Cable


impedance and Cable length
(IDU-ODU)
Channel Spacing
*1

ODU side: N type female, 50 ohms (Coaxial)


IDU side: TNC type female, 50 ohms (Coaxial)
300m (in case 8D-FB cable or equivalent cable)

QPSK (PDH)
16QAM (PDH)

Not Applicable

32QAM (PDH)
128QAM
Environmental
Requirement

28 (27.5) MHz

28 (27.5) MHz

Guaranteed
Operation

ODU: 33 to +50C
IDU: 5 to +50C

Workable
Operation

ODU: 40 to +55C
IDU: 10 to +55C
ODU, IDU: 40 to +70C

Transportation/
Storage
Relative
humidity

ODU: 100% applicable


IDU: Less than 90% at +50C (Non-codensing)

EMC

Conforms to EN301 489-4

Safety

Conforms to EN60950
48 VDC (40.5 to 57 VDC), Conforms to EN300 132-2

Power Requirement
Power Consumption (Typical)
ODU/Unit

30 W (6 to 11GHz), 23 W (13 to 52 GHz)

IDU Card/Unit
MODEM

10 W

STM-1O INTFC

5W

STM-1E INTFC

5W

LAN/WS INTFC

CTRL

MODEM: 0.5 kg, STM-1O INTFC: 0.3 kg, STM-1E INTFC: 0.3 kg,
LAN/WS INTFC: 0.3 kg, CTRL: 0.4 kg

Weight/Card

Mechanical
Dimension

ODU

237(W) 237(H) 101(D): Approx. 3.5 kg/Unit

IDU

482(W) 44(H) 240(D): Approx.4 kg

Notes *1: 27.5 MHz is applied for 18 GHz.


*2: 2 155Mbps using 2 sets for XPIC
*3: 2 for APS configuration

2-16

5W
7W

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.2.2 LAN Interface (10/100 Base-T(X))


Type

: 10 Base-T/100 Base-TX (Auto-sensing or fixed)

Port Number and Interface


: 2 (Each port is separated) RJ-45
Transmission Rate: Selectable and rest E1 channels
Flow control

: Full duplex or Half duplex (Backpressure)

Forwarding Mode : Store-and-Forwarding


(This interface card work as a LAN Bridge and
compliant with IEEE802.3)
Note: In case of employing main traffic LAN interface, LAN ports and
E1 ports can be used at the same time. However, the numbers of
E1 port are limited depending on the selected LAN transmission
rate as shown in the following tables.
(1) 2 Port LAN with WS INTFC
Table 2-2 2 Port LAN 150 Mbps (128QAM)

LAN Setting
LAN capacity [Mbps]
Port 1

Port 2

P1 & P2 = 150 M Best effort (separated)

150

P1 = 75 M separated

P2 = 75 M separated

150

P1 = 100 M separated

P2 = 50 M separated

150

P1 = 100 M separated

Disabled

100

2-17

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

(2) 2 Port LAN with PDH INTFC


Table 2-3 2 Port LAN 80 Mbps (16QAM)

LAN Setting

LAN capacity
[Mbps]

E1 capacity
[channels]

P1 & P2 = 80 M shared *1

80

P1 & P2=shared from 80M to 48M

(2 Mbps step)

(1 channel step)

P1 & P2 = 48M shared

48

16

Port 1

Port 2

P1 = 40M separated

P2 = 40M separated

80

P1 = 30M separated

P2 = 30M separated

60

10

P1 = 24M separated

P2 = 24M separated

48

16

Disabled

Disabled

16

*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)
(2) 2 Port LAN with PDH INTFC
Table 2-4 2 Port LAN 40 Mbps (16QAM/QPSK)

LAN Setting

LAN capacity
[Mbps]

E1 capacity
[channels]

P1 & P2 = 40 M shared *1

40

P1 & P2=shared from 40M to 8M

(2 Mbps step)

(1 channel step)

P1 & P2 = 8M shared

16

Port 1

Port 2

P1 = 20M separated

P2 = 20M separated

40

P1 = 10M separated

P2 = 10M separated

20

10

P1 = 4M separated

P2 = 4M separated

16

Disabled

Disabled

16

*1 LAN capacity can be set in 2 Mbps step. (P1 & P2 Shared mode)

2-18

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

Table 2-5 2 Port LAN 20 Mbps (16QAM/QPSK)

LAN Setting

LAN capacity
[Mbps]

E1 capacity
[channels]

P1 & P2 = 20M shared

20

P1 & P2= shared from 20M to 4M

(2 Mbps step)

(1 channel step)

P1 & P2 = 2M shared

Port 1

Port 2

P1 = 10M separated

P2 = 10M separated

20

Disabled

Disabled

10

Table 2-6 2 Port LAN 10 Mbps (16QAM/QPSK)

LAN Setting

LAN capacity
[Mbps]

E1 capacity
[channels]

P1 & P2 = 10M shared

10

P1 & P2 = shared from 10M to 2M

(2 Mbps step)

(1 channel step)

P1 & P2 = 2M shared

Disabled

Port 1

Disabled

Port 2

2.2.3 LAN Interface (GbE)


Table 2-7 GbE LAN

Type

1000 Base-SX (IEEE 802.3z)

1000 Base-T (IEEE 802.3ab)

Throughput

150 Mbps

150 Mbps

Connector type

LC

RJ-45

Port Number

1 port

1 port

2-19

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.2.4 Service Channel (SC)


SC1 and SC2

: RS-232C, 9.6 kbps async.

SC3 and SC4

: V.11, 64 kbps (Contra/Co-directional: Selectable)

SC5

: EOW 1 channel

Connector

: High Density D-sub 44 ways

LAN Interface

: SC LAN Interface
(in case of using SC LAN sub interface)
(Only for 155 Mbps capacity, throughput:
64/128/192/256 kbps or 2 Mbps)

2.2.5 LCT (PNMT) Interface


Serial Interface

: Connector type USB-B

2.2.6 PNMS Interface


10 Base T

: Connector RJ-45

2.2.6.1 RF I/O Port


Interface Port Type:
Antenna direct mount interface:exclusive NEC flange (11-52 GHz)
is attached to the RF IN/OUT port in
standard
Coaxial cable interface

: 6/7/8 GHz: N (Female)

Waveguide feeder interface* (Remote mount):


6 GHz: PDR70
7/8 GHz: PDR84
10/11 GHz: PDR100
13 GHz: PBR120
15 GHz: PBR140
18/23 GHz: PBR220
26 GHz: PBR260
28/32/38 GHz: PBR320
52 GHz: N/A
Polarization
: Field changeable (Vertical or Horizontal)
Note: For the ODU of waveguide connection type, waveguide flange
adapter is attached to the RF IN/OUT port of remote mount ODU
in standard.

2-20

ROI-S05748

SYSTEM CONFIGURATION AND CHARACTERISTICS

2.2.6.2 Parallel Alarm Interface


Output port

: Relay Contact (Form-C); 6 outputs max.


(assignable 4 outputs for multiple items)

Input port

: Photo coupler; 6 items max.

Cluster ALM
IN/OUT

Connector

: 4 items (max.)
(Up to four cluster alarms are provided. For each
cluster alarm IN corresponding cluster alarm OUT
should be assigned in the opposite station.
: High Density D-sub 44 ways

2.2.6.3 Wayside
In case of 155 Mbps capacity, one (1) wayside channel can be used as E1
using optional LAN/WS interface card.
In case of 2E3 INTFC, eight (8) wayside channels can be used as E1 or
LAN INTFC
In case of 1E3 INTFC, four (4) wayside channels can be used as E1 or
LAN INTFC

2-21

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.2.7 ODU (Outdoor Unit) and System performance


Table 2-8 System Performance for QPSK/ODU
Frequency Band (GHz)
Range [GHz]

Interface
type

Direct
Mount
Remote
mount

*2

Output Power, nominal


(dBm) (Measured at ODU
output port)

7-8

10-11

13

15

18

23

26

28

32

38

52

Guaranteed

5.9257.11

7.128.5

10.1511.7

12.7513.25

14.2515.35

17.719.7

21.323.6

24.2527.5

27.529.5

31.833.4

37.040.0

51.452.6

N/A

N/A

N type N type
or
or
PDR 70 PDR 84

PDR
100

PBR
120

PBR
140

PBR
220

PBR
220

PBR
260

PBR
320

PBR
320

PBR
320

N/A

+29

+25

+25

+23

+24

+24

+22

+22

+22

+18

+3

6-26G:1.5 dB
28-52G:+1.5/2.5 dB

*4

0 to 10 dB

1.0 dB

*4

0 to 10 dB

*3

Power Control (1 dB step,


variable)

0 to 30 dB

ATPC (1 dB step)

0 to 30 dB

0 to 25 dB

*3

0 to 25 dB
6 ppm

Frequency Stability

28 (27.5)

10 ppm

-6
(dBm), (Measured at ODU input port) at BER = 10

Threshold Level
Channel Separation (CS)=

NEC Original

84

83

83

83.5

83.5

83.5

83

83

81.5

81.5

78

87

86

86

86.5

86.5

86.5

86

86

84.5

84.5

81

90

89

89

89.5

89.5

89.5

89

89

87.5

87.5

84

*1 MHz
+3.0 dB

14 (13.75)

*1

MHz

7 MHz

Above value 1.5 dB

BER = 10-3

-6

System Gain

(dB), (Measured at ODU input port) at BER = 10

Channel Separation (CS)=


28 (27.5)

*1

14 (13.75)

*1

113

108

108

106.5

107.5

107.5

105

105

103.5

99.5

81

116

111

111

109.5

110.5

110.5

108

108

106.5

102.5

84

119

114

114

112.5

113.5

113.5

111

111

109.5

105.5

87

MHz
MHz

7 MHz
BER = 10-3

Above value +1.5 dB

Maximum Input Level

15 dBm (No Error)

Residual BER

2-22

Less than 10

6-26G:3.0 dB
28-52G:4.0 dB

-12 at RSL= 30 dBm

*1

13.75 MHz and 27.5 MHz are applied for 18 GHz.

*2

For the ODU of waveguide connection type, flange adapter


is attached to the RF IN/OUT port of remote mount ODU in
standard.

*3

When additional 5 dB (maximum) attenuation is added.

*4

Additional attenuation is unavailable.

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

Table 2-9 System Performance for 16QAM/ODU


Frequency Band (GHz)
Range [GHz]

Interface
type

Direct
Mount
Remote

*2

mount

Output Power, nominal (dBm)


(Measured at ODU output port)

7-8

10-11

13

15

18

23

26

28

32

38

Guaranteed

5.9257.11

7.128.5

10.1511.7

12.7513.25

14.2515.35

17.719.7

21.323.6

24.2527.5

27.529.5

31.833.4

37.040.0

N/A

N/A

PDR
100

PBR
120

PBR
140

PBR
220

PBR
220

PBR
260

PBR
320

PBR
320

PBR
320

+26

+21.5

+22.5

+22.5

+22

+22

+20

+18

+17

+14.5 6-26G:1.5 dB
28-38G:+1.5/2.5 dB

*3

1.0 dB

*3

0 to 24 dB

ATPC range

0 to 24 dB

6 ppm

Frequency Stability

*1

14 (13.75)

(dBm), (Measured at ODU input port) at BER = 10


77

76

76

76.5

76.5

76.5

76

76

74.5

74.5

80

79

79

79.5

79.5

79.5

79

79

77.5

77.5

83

82

82

82.5

82.5

82.5

82

82

80.5

80.5

86

85

85

85.5

85.5

85.5

85

85

83.5

83.5

MHz

*1

MHz

7 MHz
3.5 MHz
BER = 10

10 ppm

-6

Threshold Level

28 (27.5)

-6

(dB) , (Measured at ODU input port) at BER = 10


103

97.5

98.5

99

98.5

98.5

96

94

91.5

89

*1 MHz
14 (13.75)

106

100.5

101.5

102

101.5

101.5

99

97

94.5

92

7 MHz

109

103.5

104.5

105

104.5

104.5

102

100

97.5

95

3.5 MHz

112

106.5

107.5

108

107.5

107.5

105

103

10.5

98

Channel Separation (CS)=

*1

+3.0 dB

Above value 1.5 dB

-3

System Gain

28 (27.5)

N type N type
or
or
PDR 70 PDR 84

Power Control (1 dB step,


variable)

Channel Separation (CS) =

NEC Original

MHz

3.0 dB

BER = 10-3

Above value +1.5 dB


20

Maximum Input Level

dBm for the BER less than 10-3


-12

Residual BER

Less than 10

at RSL = 30 dBm

*1

13.75 MHz and 27.5 MHz are applied for 18 GHz.

*2

For the ODU of waveguide connection type, flange adapter


is attached to the RF IN/OUT port of remote mount ODU in
standard.

*3

Additional attenuation is unavailable.

2-23

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

Table 2-10 System Performance for 32QAM/ODU


Frequency Band (GHz)
Range [GHz]

Interface
type

Direct
Mount
Remote

*2

mount

7-8

10-11

13

15

18

23

26

28

32

38

52

Guaranteed

5.9257.11

7.128.5

10.1511.7

12.7513.25

14.2515.35

17.719.7

21.323.6

24.2527.5

27.529.5

31.833.4

37.040.0

51.452.6

N/A

N/A

N type N type
or
or
PDR 70 PDR 84

PDR
100

PBR
120

PBR
140

PBR
220

PBR
220

PBR
260

PBR
320

PBR
320

PBR
320

N/A

+25

+21

+21

+21

+19

+19

+18

+18

+17

+14.5

6-26G:1.5 dB
28-52G:+1.5/2.5 dB

0 to 6 dB

1.0 dB

0 to 6 dB

Output Power, nominal


(dBm) (Measured at ODU
output port)
Power Control (1 dB step,
variable)

0 to 28 dB

ATPC (1 dB step)

0 to 28 dB

Threshold Level

28 (27.5)

75.5

74.5

10 ppm
+3.0 dB

74.5

75

75

74.5

74.5

73

73

73

69.5

*1 MHz
Above value 1.5 dB

System Gain

(dB), (Measured at ODU input port) at BER = 10

Channel Separation (CS)=

*1

100.5

95.5

95.5

96

94

94

92.5

92.5

-6

92.5

3.0 dB
90

87.5

66.5

MHz
Above value +1.5 dB

BER = 10-3
20

Maximum Input Level

dBm for the BER less than 10-3

-12
Less than 10

Residual BER

2-24

*3

-6
(dBm), (Measured at ODU input port) at BER = 10

BER = 10-3

28 (27.5)

*3

6 ppm

Frequency Stability

Channel Separation (CS)=

NEC Original

at RSL=30 dBm

*1

27.5 MHz is applied for 18 GHz.

*2

For the ODU of waveguide connection type, flange adapter


is attached to the RF IN/OUT port of remote mount ODU in
standard.

*3

When additional 5 dB (maximum) attenuation is added.

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

Table 2-11 System Performance for 128QAM/ODU


Frequency Band (GHz)
Range [GHz]

Interface
type

Direct
Mount
Remote
mount

*2

Output Power, nominal


(dBm) (Measured at ODU
output port)

7-8

10-11

13

15

18

23

26

28

32

38

Guaranteed

5.9257.11

7.128.5

10.1511.7

12.7513.25

14.2515.35

17.719.7

21.323.6

24.2527.5

27.529.5

31.833.4

37.040.0

N/A

N/A

PDR
100

PBR
120

PBR
140

PBR
220

PBR
220

PBR
260

PBR
320

PBR
320

PBR
320

+25

+21

+21

+21

+19

+19

+18

+18

+17

+14.5 6-26G:1.5 dB
28-38G:+1.5/2.5 dB

*3

0 to 25 dB

ATPC range)

0 to 25 dB

Threshold Level

*1

69.5

*4

1.0 dB

*4

0 to 20 dB

*3

0 to 20 dB
6 ppm

10 ppm

-6
(dBm), (Measured at ODU input port) at BER = 10

+3.0 dB

Frequency Stability

28 (27.5)

N type N type
or
or
PDR 70 PDR 84

Power Control (1 dB step,


variable)

Channel Separation (CS)=

NEC Original

68.5

68.5

69

69

69

68.5

68.5

67

67

MHz
Above value 1.5 dB

BER = 10-3
System Gain
Channel Separation =

(dB), (Measured at ODU input port) at BER = 10


94.5

89.5

89.5

90

88

88

86.5

-6

3.0 dB
86.5

84

81.5

*1 MHz

28 (27.5)

Above value +1.5 dB

BER = 10-3
20

Maximum Input Level


Residual BER

dBm for the BER less than 10-3

Less than 10

-12

at RSL=30 dBm

*1

27.5 MHz is applied for 18 GHz.

*2

For the ODU of waveguide connection type, flange adapter


is attached to the RF IN/OUT port in standard.

*3

When additional 5 dB (maximum) attenuation is added.

*4

Additional attenuation is unavailable.

Note: XPIC system has the same condition as above.

2-25

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.2.8 IDU (Indoor Unit) and System performance


Table 2-12 System Performance for IDU
Specification
No.

Item

PDH

1
2
3

IDU type
Modulation Type
Baseband Interface

Channel Number
Total Capacity
4
5
6

SDH

LAN

1+0 Expandable/1+1
QPSK/16/32QAM
128QAM
QPSK/16/32/128QAM
E3:
155.52 Mbps 20 ppm 10/100 Base-T(X)
E1:
1000 Base-SX
2.048 Mbps 50 ppm 34.368 Mbps 20 ppm
1000 Base-T
75 ohm/120 ohm
75 ohm
75 ohm/S-1.1/L-1.1
D-sub37/MDR68 IEC 169-29 (1.0/2.3) IEC 169-29 (1.0/2.3) RJ-45 (10/100/1000 Base-T(X))
LC (1000 Base-SX)
5/10/16/20/40/48
1/2
1/2*
1/2
10/20/32/40/80/96
34/68 Mbps
155 Mbps
10/20/40/80/100/100+50,
Mbps
75+75 Mbps
V.11 (Contra/Co-directional) 2 channels, RS-232C 2 channels
IDU-IDU
See table below

Service Channels
EOW
External alarm &
House keeping
7 Security level by LCT
2 levels
8 Control &Setting by
Serial Interface (USB connector)
LCT/PNMT
Loop Back
a) Far End Baseband Loop Back
b) Near End Baseband Loop Back
c) IF Loop back
BER Alarm
Adjustable 10-3/ 10-4/ 10-5 (High BER) 10-6/ 10-7/ 10-8/ 10-9 (Low BER)
Frequency setting
Direct entry or Table Download entry: Available when using PNMx (optional)
TX output Control
Manual control, Automatic control, Mute control
9 Performance
PMON Items;
monitoring (PMON) a) OFS, b) BBE, c) ES, d) SES, e) SEP, f) UAS
/Metering
Metering Items
a) Output power level (TX PWR), b) Received signal level (AGC V) c) Bit error rate (BER MON)
LAN monitoring Items;
a) RX Unicast, b) RX Broadcast, c) RX Multicast, d) RX Pause, e) RX CRC error
10 LED Display
CTRL
IDU Alarm (Red)
Maintenance (Amber)
Memory Access (Amber)
MODEM
Operating PWR (Green)
ODU Alarm (Red)
MD/CBL Alarm (Red)
TX status (Green)
RX status (Green)
XPIC Reset (Amber)*
PDH INTFC
Module alarm (Red)
SDH INTFC
Module alarm (Red)
Online (Green)**
LAN/WS INTFC
Module alarm (Red)

* This value is available with 2 IDUs per 1 RF CH with


XPIC system.
** This indicates the online status which is selected from
Working/Standby in APS system or Warking in w/o APS
system.

2-26

ROI-S05748

SYSTEM CONFIGURATION AND CHARACTERISTICS

Table 2-13 Alarm & House Keeping Output Items


#
1
2
3
4
5
6
7

Alarm Item
displayed
on LCT/PNMT

MAINT
IDU CPU ALM
PS ALM1
PS ALM2
ODU ALM1
ODU ALM2
ODU CPU/CBL
OPN ALM1

Condition

System under maintenance


IDU CPU failure
PS1 failure (only1+1)
PS2 failure (only1+1)
ODU1 total alarm

ALM LED
Indication
(IDUs front)

MAINT
PWR
ODU

ODU2 total alarm


ODU
ODU1 CPU failure or IF cable is
Blinking
open
8 ODU CPU/CBL
ODU2 CPU failure or IF cable is
OPN ALM2
open
9 TX PWR ALM1
ODU1 output power decrease
ODU
10 TX PWR ALM2
ODU2 output power decrease
11 TX INPUT ALM1 ODU1 TX IF input level decrease
ODU
12 TX INPUT ALM2 ODU2 TX IF input level decrease
13 APC ALM1
ODU1 LO OSC APC loop out of
ODU
lock
14 APC ALM2
ODU2 LO OSC APC loop out of
lock
15 RX LEV ALM1
ODU1 Receiving level decrease
ODU
16 RX LEV ALM2
ODU2 Receiving level decrease
17 IF CABLE SHORT IF Cable connected to ODU1 short
IDU
ALM1
MD/CBL
Blinking
18 IF CABLE SHORT IF Cable connected to ODU2 short
ALM2
19 IDU ALM
IDU total alarm
IDU
20 MOD ALM1
MOD PLL APC loop out of lock,
IDU
MOD output level down or TX
MD/CBL
DPU CLK loss in MODEM1
21 MOD ALM2
MOD PLL APC loop out of lock,
MOD output level down or TX
DPU CLK loss in MODEM2
22 DEM ALM1
Carrier Asynchronous,
IDU
Frame Asynchronous at DPU in
MD/CBL
MODEM1
23 DEM ALM2
Carrier Asynchronous,
Frame Asynchronous at DPU in
MODEM2
24 HIGH BER ALM1 BER > 10E-3 to -5 (selectable) in
IDU
MODEM1
MD/CBL
25 HIGH BER ALM2 BER > 10E-3 to -5 (selectable) in
MODEM2
26 LOW BER ALM1 BER > 10E-6 to -9 (selectable) in
IDU
MODEM1
MD/CBL
27 LOW BER ALM2 BER > 10E-6 to -9 (selectable) in
MODEM2
28 LOF1
Loss of Radio frame
IDU
synchronization in MODEM1
MD/CBL
29 LOF2
Loss of Radio frame
synchronization in MODEM2
30 INPUT LOSS
Loss of input data stream
IDU INTFC
CH 1-48
from DTE <Note 1>
<Note7>
AIS (all 1) is received
IDU INTFC
31 AIS RCVD
CH 1-48
from DTE <Note 1>
<Note7>
32 AIS GENERATED AIS (all 1) is sent to
IDU INTFC
CH 1-48
DTE <Note 1>
<Note7>

Summarized Alarm Output


(Form-C) <Note 3,4,5,10>
RL1

RL2

RL3

RL4

RL5

RL6

MASK MASK MASK MASK

2-27

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

Table 2-13 Alarm & House Keeping Output Items (Contd)


#

Alarm Item
displayed
on LCT/PNMT

33 CH USAGE ERROR
CH 1-48

34 LAN LINK PORT


1-4
35 STM-1(1/2) LOS
(MUX)
36 STM-1(1/2) LOS
(DMR)
37 STM-1(1/2) TF
ALM
38 WS INPUT LOSS
39 INTFC (2) LAN
LINK PORT
40 XCTRL ALM1

Condition

ALM LED
Indication
(IDUs front)

Use of a channel set as not used


(E1 channel) <Note 2>
Loss of Main LAN Link <Note 3>

IDU INTFC
<Note7>
IDU INTFC

Loss of input data stream


from MUX <Note 3>
Loss of input data stream
from DMR <Note 3>
Loss of STM-1 signal output to
MUX <Note 3>
Loss of Wayside signal input

IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note8>
IDU INTFC
<Note9>
IDU INTFC
<Note9>
IDU INTFC
<Note9>
IDU INTFC
<Note9>
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT
Only show
PNMT

Loss of SC LAN Link

44 HK-OUT1

Control failure or REF


Signal failure
Control failure or REF
Signal failure
Control failure or REF
Signal failure
Control failure or REF
Signal failure
House keeping Control out1

45 HK-OUT2

House keeping Control out2

46 HK-OUT3

House keeping Control out3

47 HK-OUT4

House keeping Control out4

48 Cluster ALM out1

This item received from


opposite site. Item 1
This item received from
opposite site. Item 2
This item received from
opposite site. Item 3
This item received from
opposite site. Item 4

41 XCTRL ALM2
42 XREF ALM1
43 XREF ALM2

49 Cluster ALM out2


50 Cluster ALM out3
51 Cluster ALM out4

Summarized Alarm Output


(Form-C) <Note 3,4,5,10>
RL1

RL2

RL3

RL4

RL5

RL6

Note 1: Apply to each channel of E1/E3.


Note 2: Unused channel/interface is masked according to the bit rate.
Note 3: It is possible to change capacity between E1 and Ethernet under working
condition.
Note 4: In MAINT status, excepting HK-OUT and Cluster ALM, alarm outputs are masked
to normal condition.
Note 5: The summarization of alarm outputs is fully user programmable; The sign
in
above table shows fixed item and can not be changed. The sign only shows the
factory settings. The sign
output can be assigned for plural items. The sign
input/output can not be assigned. Either HK output or Cluster ALM output
in each channel can be assigned.
Note 6: Above Table shows Alarm output matrix for 1+1 configuration
Note 7: Only apply to PDH system.
Note 8: Only apply to SDH system.
Note 9: Only apply to XPIC system.
Note 10:Assign to relays 4 to 6 only one category, either pasolink Alarm, House Keeping
Control out or Cluster Alarm out.

2-28

ROI-S05748

SYSTEM CONFIGURATION AND CHARACTERISTICS

Output Port condition


Interface circuit: Relay Form C
Maximum Current: 0.2 A
Maximum Voltage: 100 V (AC+DC)

Relay
Event/ Alarm Open
(Normally closed)

Event/ Alarm Close


(Normally open)
COM

Table 2-14 House keeping input Items


#
1
2
3
4
5
6
7
8
9
10

House keeping Item


displayed
on LCT/PNMT

HK-IN1
HK-IN2
HK-IN3
HK-IN4
HK-IN5
HK-IN6
Cluster ALM input1
Cluster ALM input2
Cluster ALM input3
Cluster ALM input4

Condition

Event Indication

Summarized Alarm Input


(Photo coupler)
IN1 IN2 IN3 IN4

House keeping Event inport1


House keeping Event inport2
House keeping Event inport3
House keeping Event inport4
House keeping Event inport5
House keeping Event inport6
This item transmits to opposite site. Item 1
This item transmits to opposite site. Item 2
This item transmits to opposite site. Item 3
This item transmits to opposite site. Item 4

IN5

IN6

Only show PNMT


Only show PNMT
Only show PNMT
Only show PNMT
Only show PNMT
Only show PNMT
Only show PNMT
Only show PNMT
Only show PNMT
Only show PNMT

Note 1: Unused channel/interface is masked according to the bit rate.

Input Port condition


+3.3 V
Normal OPEN (> 200 k ohms)
Control CLOSE (< 50 ohms)
Interface circuit: photo coupler with bias circuit

+3.3 V

Normally Open
Control Closed

2-29

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.3 Interconnection between ODU and IDU


Table 2-15 IF Cable
No.

Item

Specification

Interconnection

Single coaxial cable /50 ohms

Standard Type of Cable

5D-FB, 8D-FB (standard), 10D-FB

Signals

IF signal, alarms, control, monitoring and power source

Maximum Cable Length

150 m (5D-FB)
300 m (8D-FB)
350 m (10D-FB)

Cable Equalization

Automatic level equalization

Guaranteed temperature range

33C to +50C (workable : 40C to +55C)

Note 1 : In case of employing hitless protection, set each length


of two IF cables same or the difference of their cable
length shall be less than 100 meters.
Note 2 : Salt damage (custom order)
In case of operating in the sea or around the coast area
(within 3 km from coastline), measure must be taken for
the ODU against salt damage. Please contact NEC for
the countermeasure.
Note 3 : Water Proof N type connector
The waterproof N type connectors must be used for IF
cable of ODU side, because DC voltage power is
supplied in it.
Note 4 : IDU IF connector = TNC (Female),
ODU IF connector = N (Female)
Note 5 : TNC (Male) L-angle connector for the 8D-FB IF cable
is used to connect it to the IDU. When the N (Male)
straight connector is attached to the 5D-FB or 10D-FB
IF cable, the TNC (Male) - N (Female) L-angle adapter
is used.

2-30

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.4 Hybrid Combiner/Divider


There are two types of hybrid combiner/divider used in 1+1 protected
systems, one is coaxial cable connection type for 6/7/8 GHz Bands and the
other is ODU Direct Mount type for 11 - 52 GHz Bands. The following
NEC Hybrid Combiner/Divider is suited for Andrew or RFS Antenna, and
all NEC ODUs.

6/7/8 GHz Hybrid

11 - 52 GHz Hybrid

Fig. 2-6 Hybrid

Table 2-16 Characteristics


Frequency
Band
[GHz]
L6
U6
7
8
11
13
15
18
23
26
32
38
52

Frequency
Range
[GHz]
5.925
6.43
7.125
7.7
10.5
12.75
14.5
17.7
21.2
24.5
31.8
37
51.4

6.425
7.11
7.9
8.5
11.7
13.25
15.35
19.7
23.6
26.5
33.4
39.5
52.6

1-2 PORT
Variation
Max.(dB)

Loss Max.
(dB)

Isolation
Min.(dB)

VSWR Max.

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

3.7
3.7
3.7
3.7
3.5
3.5
3.5
3.5
3.5
3.8
3.8
3.8
4.5

20
20
20
20
20
20
20
20
20
20
20
20
20

1.3
1.3
1.3
1.3
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3

Interface
(ANT Side) (ODU Side)
UDR70
UDR70
UDR84
UDR84

N Connector
N Connector
N Connector
N Connector

NEC
original

NEC
original

* Custom ordered for 28 GHz.

2-31

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.4.1 10 dB Coupler
There are two types of NEC 10 dB Coupler; one is coaxial cable
connection type for 6/7/8 GHz bands and the other is ODU Direct Mount
type for 11 - 38 GHz Bands. The following 10 dB Coupler is suited for
Andrew or RFS Antenna, and all NEC ODUs.

11 - 38 GHz Coupler

6/7/8 GHz Coupler (N-Type)


Fig. 2-7 10 dB Coupler

Table 2-17 Characteristics


Frequency
Band
[GHz]
L6/U6
7/8

Frequency
Range
[GHz]
5.925 - 7.125
7.125 - 8.5

Loss Max.
(dB)

Isolation
Min.(dB)

VSWR Max.

(ANT Side)

(ODU Side)

0.5

1.2

20

1.3

UDR70

N Connector

UDR84

N Connector

NEC original

NEC original

0.5

1.2

20

1.3

0.5

1.2

20

1.2

11

10.5 - 11.7

13

12.75 - 13.25

0.5

1.2

20

1.2

15

14.5 - 15.35

0.5

1.2

20

1.2

18

17.7 - 19.7

0.5

1.2

20

1.2

23

21.2 - 23.6

0.5

1.2

20

1.2

26

24.5 - 26.5

0.5

1.2

20

1.2

32

31.8 - 33.4

0.5

1.2

20

1.2

38

37 - 39.5

0.5

1.2

20

1.2

* ODU for 6/7/8 GHz: Separate Type


* ODU for 11 - 38 GHz: Direct Mount Type
* Custom ordered for 28 GHz.

2-32

Interface

1-2 PORT
Variation
Max.(dB)

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.4.2 OMT (Ortho-Mode Transducer)


The OMT enables dual polarization feature to double the transmission
capacity for the PASOLINK system using the same frequency. The
following NEC OMT has ODU Direct Mount type for 11-38 GHz Bands,
which is suited for RFS Antenna and all NEC ODUs.

Fig. 2-8 OMT Transducer

Table 2-18 Characteristics


Frequency
Band
[GHz]

Frequency
Range
[GHz]

XPD Min.
[dB]

LOSS Max.
[dB]

P-P
ISOLATION
Min.[dB]

VSWR Max.

INTERFACE WG
(ODU
INNER DIA. (mm) INTERFACE
Side)
(ANT Side)

11

10.5 - 11.7

35

0.6

38

1.3

18.0

13

12.75 - 13.25

35

0.6

38

1.3

15.0

15

14.5 - 15.35

35

0.6

38

1.3

13.5

18

17.7 - 19.7

35

0.6

38

1.3

10.5

23

21.2 - 23.6

35

0.6

38

1.3

9.0

26

24.5 - 26.5

35

0.8

38

1.3

8.0

32

31.8 - 33.4

35

1.0

38

1.3

6.5

38

37 - 39.5

35

1.0

38

1.3

5.5

NEC original

2-33

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.5 RF Channel Plan


Radio frequencies in 6 to 52 GHz applicable to PASOLINK NEO are
shown in the following Table:
For details of frequency range in each Sub Band RF frequency band listed
below, refer to the Appendix attached in this Section 1.
Table 2-19 RF Frequencies
RF BAND [GHz]

2-34

L6 GHz

: 5.925 - 6.425

U6 GHz
7 GHz

: 6.43 - 7.11
: 7.125 - 7.9

8 GHz

: 7.7

10-11 GHz
13 GHz
15 GHz

: 10.15 - 11.7
: 12.75 - 13.25
: 14.5 - 15.35

18 GHz

: 17.7

- 19.7

23 GHz

: 21.2

- 23.6

26 GHz

: 24.5

- 26.5

28 GHz
32 GHz
38 GHz

: 27.5
: 31.8
: 37

- 29.5
- 33.4
- 39.5

52 GHz

: 51.4

- 52.6

- 8.5

Tx-Rx Shift Frequency [MHz]

252.04/
266
340
154/
161/
196/
245
119/
126/
151.614/
154/
266/
294.44/
305.56/
311.32
530
266
315/
420/
470/
490/
644/
728
340/
750/
1008/
1010/
1092.5/
1120/
1250/
1560
600/
1008/
1200/
1232
855/
1008/
1123.5
1008
812
700/
1000/
1260/
616

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

2.6 Power Supply


The power supply systems are shown in Fig. 2-9 (1/3) to (3/3). The DCDC CONV module in the MODEM module produces regulated +3.6 V DC
from 48 V *1 DC input for the component modules on the IDU. Also,
this module supplies a 48 V DC to the ODU.
Caution: * 1

The 48 V power supply system for the PASOLINK


NEO must be separated from existing power supply
system. The PASOLINK, PASOLINK+, PASOLINK
Mx, etc. That uses 43 V DC and floating polarities.

*2

When at EHG type ODU (not NEO) is connected to


the IDU NEO, it is recommended to install optional
DC-DC CONV module into the IDU as shown in Fig.
2-9 (3/3). If the optional DC-DC CONV module is not
used, the EHG ODU lifetime or the ODU may be
damaged.

The DC V to the ODU is supplied through the coaxial cable which is also
used for the IF and other signals. The PS circuit on the ODU produces +7/
+8/+9/7/8/9 * and 15 V DC for the component modules from the 48
V DC supplied from the IDU.
Note: *: Necessary voltages in the ODU vary depending on the ODU
type.
IDU
ODU (NEO)
MODEM

ODU INTFC

TX IF
RX IF
SV/CTRL

48 V

SEP/
COMB
FIL

48 V

DC
INPUT

48 V
G

SEL V
(2/4)
(1/3)

SV/CTRL

PS

PWR
FUSE

DC-DC
CONV

TX IF
RX IF

SEP/
COMB
FIL

15 V
7/8/9 V *1
+7/+8/+9 V *1

+3.6 V
48 V

*2
CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC, E3
INTFC, LAN/WS INTFC, GbE INTFC,

Notes:

For 1+0 Configuration

*1: The inner voltages vary depending on the ODU type.


*2: Optional
For 1+0 Configuration

Fig. 2-9 Power Supply System Block Diagram (1/3)

2-35

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

IDU
MODEM

ODU (NEO)
ODU INTFC

TX IF
RX IF
SV/CTRL

48 V

SEP/
COMB
FIL

48 V

DC
INPUT

48 V

SEL V
(2/4)

SV/CTRL

DC-DC
CONV

FUSE

15 V
7/8/9 V *1
+7/+8/+9 V *1

PS

PWR

(1/3)

TX IF
RX IF

SEP/
COMB
FIL

+3.6 V
48 V

*2
CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC,
E3 INTFC, LAN/WS INTFC, GbE INTFC,

DC
INPUT

48 V
G

SEL V
(2/4)

PWR
FUSE

(1/3)

DC-DC
CONV

+3.6 V

ODU (NEO)

TX IF
RX IF
SV/CTRL

SEP/
COMB
FIL

48 V

SEP/
COMB
FIL

48 V

MODEM

SV/CTRL

ODU INTFC

PS
48 V

Notes:

*1: The inner voltages vary depending on the ODU type.


*2: Optional
For 1+1 Configuration

Fig. 2-9 Power Supply System Block Diagram (2/3)

2-36

TX IF
RX IF

15 V
7/8/9 V *1
+7/+8/+9 V *1

SYSTEM CONFIGURATION AND CHARACTERISTICS

ROI-S05748

ODU (Excepting NEO)

IDU
20 to 60 V/
+20 to +60 V
()

DC
INPUT (+)

SEL V
(2/4)

PWR
ODU INTFC

FUSE

(1/3)

TX IF
RX IF
SV/CTRL

FUSE
(2) 43 V
DC-DC
CONV

(1) G
OUT

43 V

SEP/
COMB
FIL

SEP/
COMB
FIL

43 V

SV/CTRL

DC-DC CONV *2
SEL V
(2/4)
(1/3)

PS

PWR
DC-DC
CONV

FUSE

TX IF
RX IF

15 V
7/8/9 V *1
+7/+8/+9 V *1

+3.6 V
43 V

MODEM
*2
CTRL, STM-1 INTFC, 16E1 INTFC, 48E1 INTFC,
E3 INTFC, LAN/WS INTFC, GbE INTFC

Notes:

*1: The inner voltages vary depending on the ODU type.


*2: Optional
For 1+0 Configuration
Connecting Other Type Pasolink ODU

Fig. 2-9 Power Supply System Block Diagram (3/3)

2-37

SYSTEM CONFIGURATION AND CHARACTERISTICS

(This page is intentionally left blank.)

2-38
38 pages