Professional Documents
Culture Documents
Al-Habbtour Metropolitan Hotel Design of Footings Data Base
Al-Habbtour Metropolitan Hotel Design of Footings Data Base
ANTOINE BOUCHDID
TEL :01/483103-4 03/607030
-Reinforced Concrete:
Concrete class: C35/45; fc28=35Mpa.
Minimum clear concrete cover:
-In footings: Bottom steel: 7.5cm.
Top steel:
3cm.
-In walls:
at outside face: 7.5cm.
at inner face: 3cm.
-In slabs (15cm thickness) top & bottom: 3cm.
Blinding concrete thickness under footing=10cm.
Under slab(15cm thick.)=5cm.
Steel:
For principal and transversal reinforcement use HA420 (noted: T);
Fy=420Mpa.
-Design Codes:
Reinforced concrete design: BAEL91 E.L.S. (tat limite de service:
Service load factor design).
Footing dimensions: DTU 13.12
Design program: Robo97 Version 13.0