11
122 132 1 failure
S122
1 no failure
X T
2. Compressive fibre failure for 11 < 0
2
11
1 failure
1 no failure
X C
3. Tensile matrix failure for 22 + 33 > 0
22 33
YT2
2
2
232 22 33 12 13 1 failure
2
S 23
S122
1 no failure
C
22
33
1
YC
4 S 232
S 232
S122
2 S23
1 no failure
33
1 failure
1 no failure
ZT
6. Interlaminar compression failure for 33 < 0
2
33
1 failure
1 no failure
ZC
where, ij denote the stress components and the tensile and compressive allowable
strengths for lamina are denoted by subscripts T and C, respectively. XT, YT, ZT denotes
the allowable tensile strengths in three respective material directions. Similarly, X C, YC,
ZC denotes the allowable tensile strengths in three respective material directions. Further,
S12, S13 and S23 denote allowable shear strengths in the respective principal material
directions.
Reference:
Hashin Z. Failure criteria for unidirectional fibre composites, ASME Journal of Applied