Professional Documents
Culture Documents
AlteredCastTechnique
CorrectedCast
ModifiedCast
DestroyedCast
AlteredCastImpressions
Impressionofsofttissueifnot
capturedinframeworkimpression
Purpose
Improveadaptationofthedenturebasetothe
ridgetominimizemovementduringfunction
Equalizestressbetweenridgeandabutments
Improvecontoursofperipheries
WhenNeeded
Mandibulardistalextensions(ClassI&II)
Extensiveedentulousspans
Anycasewhereperipheryisdistorted&
needscorrection
Lessnecessaryinmaxilladuetomajor
connectorcontactwithpalate
ImpressionTechnique
Frameworkmustfitintraorally
Addtraytoframework
1mmwaxrelief
Heatandfullyseatframeworkintowax
CheckSeatingonCastandinMouth
Aftertrayadded
Restsmustbefullyseated
Tissuestopcontactscast
Noresistanceasframework
seated
CheckPeripheries
23mmshortofvestibular
Nodisplacementwhen:
Pulloncheeks,lips
Patientactivatestongue
BorderMold
Sameasadenture
AlteredCastImpression
Removewaxspacer
Coattraywithadhesive
AlteredCastImpression
Polyvinylsiloxane
Carefullyloadtray
nomaterialunderrests,
guideplanes,major
connector
SeatwithpressureONLY
overrests
NoPressureOverTray
Willcausetissuecompression
pressure
spring-back
Remove&InspectImpression
Fullyseated
Nomaterialunderrestsor
minorconnectors
SendtoLaboratory
LabSteps
Sectioncast
Placeretentivegroovesincast
Ensurenocontactbetween
impressionmaterial&cast
Stickywaxframeworkinplace
LabSteps
Boximpression
Sealretainer,major&minor
connectorborders
Pournewridgeareasin
differentcolorstone
PotentialProblemswiththe
AlteredCastTechnique
Frameworknotseatedeitherduring
impression(materialunderrest,gp)or
whenbeingpouredwillresultinanRPD
thatwontfitproperlyonteeth/tissues
Stoneleakingoverteethduringpouring
makesarticulationimpossible
NextStep
Labaddsrecordbaseand
occlusionrimtoframework
forjawrelationrecords