Chain Winding

Chain winding is similar to mush winding, except that both coil sides have equal length and a diamond shape. The example shows chain winding calculations for a 3-phase winding with 12 slots, 2 poles, and 3 coils per group. The number of coil groups is 3, with 2 slots per coil and a coil pitch of 6 slots shortened to 5 slots. The electrical angle is 360 degrees, the angle between slots is 30 degrees, and the distance between phases is 4 slots.

Uploaded by

abenet bekele
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
100% found this document useful (4 votes)
8K views6 pages

Chain Winding

Chain winding is similar to mush winding, except that both coil sides have equal length and a diamond shape. The example shows chain winding calculations for a 3-phase winding with 12 slots, 2 poles, and 3 coils per group. The number of coil groups is 3, with 2 slots per coil and a coil pitch of 6 slots shortened to 5 slots. The electrical angle is 360 degrees, the angle between slots is 30 degrees, and the distance between phases is 4 slots.

Uploaded by

abenet bekele
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd

CHAIN WINDING

In all aspects, this winding is similar to that of


mush winding except that both coil sides of a coil
have equal length and diamond shape.

Example # 3 : on Chain Winding


Given data
S=12; p=2;m=3; a=1; type=chain

Solution

a)

The number of coil groups, K

K 3
b)

i.e. there is one coil group per phase

The number of slots per pole per phase, q

q
c)

P
2
3 3
2
2

S
12

2
m p 3 2

i.e. there are two coils in a group

Coil pitch

YS

S 12

6
p 2

Full-Pitch

This is an even number and hence winding is not possible with an even coil span .
There fore , it is shortened by one slot and a coil span of 5 slots is used.

d)

The electrical angle,

e)

The angle between adjacent slots,

f)

360

30
S
12
The distance between
the beginning of each phase,

180 P 180 2 360

120 120

4 slots

30

g)

If the beginning of Phase A is slot 1,


then the beginning of phase B =1+=5
and the beginning of phase C =1+2=1+8=9

Phase sequence

10

11

12

Connection diagrams

You might also like