You are on page 1of 1

NOTES:-

CONTRACTOR TO ALLOW FOR


TEMPORARY PROPPING OF
UNDERPINNING AND BASE OF
EXISTING FOUNDATIONS UNTIL RC
RETAINING WALL IS POURED AND
CURED

ALL DIMENSIONS TO BE
CHECKED ON SITE

ALL SSL LEVELS ARE TO BE


CONFIRMED PRIOR TO RC
DETAILING.

FINISHES TO
ARCHITECTS DETAILS

PILE DESIGN BY SPECIALIST


CONTRACTOR
ALL DIMENSIONS TO BE
CHECKED ON SITE

ALLOW FOR 50mm BINDING ON 150mm


WELL COMPACTED HARDCORE UNDER
ALL SLABS & PILE CAPS/GROUND
BEAMS.
BLINDING AND HARDCORE NOT
SHOWN FOR CLARITY

ALL SSL LEVELS ARE TO BE


CONFIRMED PRIOR TO RC
DETAILING.
RC RETAINING WALL

2.

THIS DRAWING IS TO BE READ IN


CONJUNCTION WITH ALL RELEVANT
ARCHITECTS, SERVICE ENGINEERS,
SPECIALISTS, QED STRUCTURES DRAWINGS,
SPECIFICATIONS AND BILL OF QUANTITIES.

3.

ANY DISCREPANCIES OR VARIATIONS ARE TO


BE REPORTED IMMEDIATELY TO QED
STRUCTURES FOR CLARIFICATION BEFORE
THE AFFECTED WORK COMMENCES.

4.

ALL DIMENSIONS ARE TO BE CHECKED ON


SITE, ANY DISCREPANCIES TO BE REPORTED
TO QED STRUCTURES IMMEDIATELY BEFORE
THE AFFECTED WORK COMMENCES.

5.

ALL PROPRIETARY PRODUCTS ARE TO BE


USED IN ACCORDANCE WITH THE
MANUFACTURERS DETAILS AND
SPECIFICATIONS.

6.

THE CONTRACTOR IS TO ENSURE THAT


TEMPORARY LOADS PLACED ONTO THE NEW
STRUCTURES SHALL BE LESS THAN THE
LOADS FOR WHICH IT HAS BEEN DESIGNED.

7.

THE CONTRACTOR IS RESPONSIBLE FOR ALL


TEMPORARY WORKS AND FOR THE STABILITY
OF THE WORKS IN PROGRESS.

8.

FOR THE FULL COMPREHENSIVE GENERAL


NOTES SEE GENERAL NOTES DRAWING 100.

PILE DESIGN BY SPECIALIST


CONTRACTOR

ALLOW FOR 50mm BINDING ON 150mm


WELL COMPACTED HARDCORE UNDER
ALL SLABS & PILE CAPS/GROUND
BEAMS.
BLINDING AND HARDCORE NOT
SHOWN FOR CLARITY

ADJACENT SITE APPROX.


GROUND LEVEL + 17.000

WATERPROOFING AND FIRE


PROTECTION TO
ARCHITECTS DETAILS

75mm SCREED WITH


ANTI CRACK MESH
EXISTING EXTERNAL
WALL TO UNIT 7

EXISTING
NEIGHBORING WALL

120mm INSULATION TO
ARCHITECTS DETAILS
MASS CONCRETE TO EXISTING
FOUNDATION TO BE BROKEN BACK SO
FLUSH WITH FACE OF EXISTING WALL

FINISHES TO
ARCHITECTS DETAILS

300mm THK
RC40 SLAB
GROUND
F.F.L. +15.615

EXISTING GROUND LEVEL


APPROX. +15.615

THIS DRAWING IS NOT TO BE SCALED, WORK


FROM GIVEN DIMENSIONS ONLY.

WATERPROOFING AND FIRE


PROTECTION TO
ARCHITECTS DETAILS

FINISHES TO
ARCHITECTS DETAILS

RELATIONSHIP BETWEEN
EXISTING GROUND AND SSL TO
BE CONFIRMED BY ARCHITECT

1.

300mm DIA COLUMN IN


RC40, DETAILS TBC

EXISTING GROUND APPROX.


LEVEL +15.55

GROUND
S.S.L. +15.405
S.S.L. +15.405
EXISTING FOUNDATIONS
BASED ON TRIAL PITS
75mm DRYPACK
WELL RAMMED
EXISTING FOUNDATIONS
TO BE CONFIRMED

H16 DOWELS BARS


BETWEEN
UNDERPINS

PILE CAP 5,
BEYOND

PILE CAP 4

COMPRESSIBLE
MATERIAL

SECTION 5-5
(1:20)

300mm PILE
BEYOND

500mm WIDE x 700mm DEEP


RC40 GROUND BEAM

IT IS ASSUMED THE EXISTING FOUNDATIONS


ARE OUTSIDE OF THE 45 DEGREE INFLUENCE
ZONE OF THE EXCAVATION FOR THE PILE CAP,
TBC ON SITE. CONTRACTOR TO ALLOW FOR
THIS PILE CAP TO BE POURED IN 1m SECTIONS
OF FOR TEMPORARY PROPPING TO THE
EXISTING FOUNDATIONS

SECTION 6-6

EXACT DEPTH TO BE CONFIRMED

EXACT DEPTH TO BE CONFIRMED

300mm PILE
BEYOND

WIDTH OF BASE OF
UNDERPIN TO MATCH
WIDTH OF EXISTING WALL
FOUNDATION

(1:20)

QED STRUCTURES
CONSULTING STRUCTURAL & CIVIL ENGINEERS

QED STRUCTURES
CONSULTING STRUCTURAL & CIVIL ENGINEERS
7 HOVE MANOR PARADE
HOVE STREET
HOVE
EAST SUSSEX
BN3 2DF
T 01273 358 035 F 01273 207 451
W www.qedstructures.co.uk

POTENTIAL SPECIAL
PERMISSIONS REQUIRED FROM
THAMES WATER - ALLOW FOR
SLEEVING OF PILES ADJACENT
TO SEWER DOWN TO LEVEL OF
SEWER

ASSUMED 1140 x 760


DEEP SEWER
T.B.C.

POTENTIAL SPECIAL
PERMISSIONS REQUIRED FROM
THAMES WATER - ALLOW FOR
SLEEVING OF PILES ADJACENT
TO SEWER DOWN TO LEVEL OF
SEWER

ASSUMED 1140 x
760
DEEP SEWER
T.B.C.