MT-4159-2007

The bridge to more efficient care

PONTA
SUPPLY BEAMS

02 |

PONTA SUPPLY BE AMS

MT-3987-2007

MT-3965-2007

MT-3978-2007

MT-4056-2007

more versatile

Uniting improved care with individual flexibility


Todays increasingly complex critical care
environments require delivering quality
care as efficiently as possible. At the same
time hospital budgets are becoming
tighter. Therefore, organizing technology
in a very flexible way and achieving that
flexibility more cost-effectively is of major
importance.

Ongoing innovation
Our products are built on a 100-year heritage of experience in healthcare, including
more than 50 years of experience in medical gas- and supply systems. With a
proven track record of innovations and
thousands of beams sold, Drger Medical
offers a high performance standard.

1958 Ceiling supply units


1975 Supply systems for anesthesia
machines
1986 Beam systems
1995 Vertical workplace concept
Gemina
1997 Ponta E/S patented cable routing enables low positioning of
medical gases, electricity, IT
2004 MediaDocking One step
connection of gases, electricity
and IT between medical devices
and supply units
2005 Color-coded control functions
for fast and intuitive positioning
of supply units

Direct light

| 03

D-1266-2009

D-1265-2009

D-1264-2009

PONTA SUPPLY BE AMS

Indirect light

Night light

A more practical approach to critical care


Drger Medical beam systems are known for
all-round patient access
ergonomic workplace design
easy positioning of medical devices
direct access to gas, electricity and IT
integrated lighting
aesthetic design and help enhance hygiene
and safety
The latest generation of the Ponta beam system
combines three previously separate systems into
one and can meet more effectively individual
therapeutic and workflow requirements in the
ICU, NICU and Recovery.
Combining various beam length and shuttle
types help optimize the work-place and improve process efficiency
A totally closed design helps prevent dust
accumulation and facilitates cleaning
Integrated lighting is specifically designed to
fulfill individual patient and caregiver needs

flexible movement

MT-465-2008

all-round patient access


small workstation footprint

04 |

PONTA SUPPLY BE AMS

all-encompassing
Connecting clinical professionals to a more effective care environment
C-workstation rack

MT-466-2008

C-workstation pole

The C-workstations are de signed for maximum utilization


of space. The equipment- pole
and carrier have a very slim
design and medical devices can
be positioned anywhere along
the length of the beam. Gas,
electricity and IT supplies are
located in the beam.

Designed for the way caregivers work


Caring for increasingly higher acuity
patients is very challenging for caregivers.
This is why a workplace that is organized
from top to bottom becomes so valuable.

Different shuttle types, supply heads


and columns can be combined to
provide high degree of workstation configurability
Vertical equipment positioning enables
unobstructed patient access

The rail system allows a defined,


secure and easy movement along the
beam
All Ponta systems are equipped with
brakes that can be operated with just
one hand

05 |

PONTA SUPPLY BE AMS

A state-of-the-art system ...


E-workstation Movita column

E-workstation Movita head

The E-workstations enable low


positioning of medical gases,
electricity and IT within the
column or head. This supports
efficient equipment exchange
and saves precious time during
transport or critical situations.
Additional supplies can be
located in the beam. A pneumatic brake prevents unintentional movement.

Designed to work in harmony with its


surroundings
A variety of lighting systems provide
individual illumination options. Cleaning is
possible at any time, independent from
patient presence, which helps speed up the
admission and discharge process within the

ICU. In addition, all systems are sealed to


make cleaning easier.
Indirect, glare-free lighting creates a
pleasant atmosphere for patients,
caregivers and visitors
Direct lighting enables comfortable reading and provides a high quality light

source for examinations


Night lighting allows caregivers to work without interrupting the patients sleep
Optional color schemes for the supply units
make the patient room more comfortable

PONTA SUPPLY BE AMS

... for caregivers, patients and visitors alike


S-workstation Agila column tube

S-workstation Agila column

If preferred, the H-option routes gases,


electricity and IT through external hoses.
This option is available for the E- and the
S-workstations.

MT-468-2008

The S-workstations maximize


positioning flexibility by incorporating a rotating arm. It enables the workstation to be
positioned to the side or headof the bed. Both shuttle and arm
include a pneumatic brake. As
with the E-workstation supplies
for medical gases, electricity
and IT are positioned low and
additional supplies can be
located in the beam.

| 06

07 |

PONTA SUPPLY BE AMS

MT-467-2008

more economical

Creating a pathway to long-term value


Cost-effective design
A broad portfolio of harmonized accessories, beams, shuttles and equipment
carriers can be combined to match a
customers specific design and budget
requirements.
A minimized number of assembly
components enables fast and easy
installation
Costs associated with repositioning
of existing services or the creation of
sub-constructions can be avoided due
to the variable positioning of the
ceiling fixations

Proven investment protection


Durability through Drgers
high quality standards
The use of common and compatible
mountings for accessories allows easy
adaptation to changing requirements
The Ponta beam system frees up
ceiling space for future installations,
such as patient-lifters and infotainment
systems
Ponta is backed by trusted
DrgerService support, which
helps reduce downtime and
optimize equipment life and lifecycle
operating costs

08 |

PONTA SUPPLY BE AMS

TECHNICAL DATA

Ceiling fixation
Heavy duty anchors and suspension tubes
Torque at the ceiling
Suspension tubes
Lengths available
Diameter
Load capacity
Supply beam
Recommended clearance height
(under side of beam to floor)
Beam width
Beam thickness
Balkenhhe
Beam weight
Beam color
Supply installation plate color
End-cap length
C-Shuttles
Load capacity
Standard rail
Load capacity rail
Linear travel
Braking
Maximum load4)
Rotation
E-Laufkatze
Linear travel
Braking
Maximum load4)

1500, 2000 mm
110 mm
250 kg each

Can be shortened as required

C-shuttle (supplies in beam)


E-shuttle (supplies in column/head)
S-shuttle (supplies in column/head)
2200, 2800, 3100, 3500 mm
588 mm
212 mm
C/H type
E/S type
NCS-S-0500 N : white
Anodized aluminum, NCS-S-0500 N, Drger Munsel blue
or according to Color Line concept3), others on request
121mm each

1800-2000 mm
2100 mm1)
2350 mm1)
Custom lengths available on request

Under each shuttle


On front of shuttle
10 kg
Complete length of beam/beams
Mechanical
Equipment pole
Equipment carrier
Equipment carrier

150 kg
25 x 10 x 294 mm

Linear travel and carrier rotation


60 kg
130 kg
170

From central point (positioned as required)


Pneumatic/Friction
Agila head/Column
Movita head/Column

550 mm (total 1100 mm)


Linear travel/Column or Head
120 kg
120 kg

If supplies are also located in the beam then a clearance height is required that permits ergonomic use!
With mixture of shuttles use highest value
See brochure Drger Color Line Order number: 90 50 361
4) Maximum load that can be carried on the supply head or column
1)
2)
3)

Max. 1100 Nm per suspension tube

25,5 kg/m2)
28 kg/m2)
Powder coated
Powder coated

PONTA SUPPLY BE AMS

| 09

TECHNICAL DATA

S-Shuttle
Linear travel
Braking
Maximum load4)
Maximum load4)
Rotation
LengthSwiveling arm

From central point (positioned as required)


Pneumatic/Pneumatic/Friction
With Agila supply head or column
With Movita supply head or column
Swiveling arm
400 mm

550mm (total 1100mm)


Linear travel/Arm/Column or Head
100 kg
100 kg
330

Lighting Systems
Indirect light
Illuminants
Control
Reading/Examination light
Illuminants
Control
Night light
lluminants
Control

According to DIN EN 12464-1


(Standard) In top of beam, removable cover
2 or 3 x 54 W fluorescent tubes
Switched/Rotational or Touch dimming
(Optional) In front profile, removable cover
2 x 24 W fluorescent tubes
Switched/ Rotational or touch dimming
(Optional) In top of beam, removable cover
1x7W
Switched

Data for planning software on request


100-127 V, 220-240 V, 50-60 Hz
according to requirements
As required
100-127 V, 220-240 V, 50-60 Hz

Supply outlets
Beam
Agila head/column
Movita head/column

Gas, electricity, IT, etc.


Max: 74 outlets (Ponta C 3500mm)
Max: 51 outlets (Agila column 1500mm)
Max: 102 outlets (Movita column 1500mm)

As required
See Product Technical Specification_Ponta
See Product Technical Specification_Agila
See Product Technical Specification_Movita

MDD 93/42/EWG
DIN EN 60601 1
DIN EN 60601-1-2
DIN EN ISO 11197
EN ISO 14071
18-046
During operation
+ 5 C up to + 40 C
< 100%

Class II b

Standards
According to Medical Device Directive
Medical electrical devices
Medical electrical devices
Medical Supply Units
Risk analysis Medical products
UMDNS code
Ambient conditions
Temperatur
Relative humidity
Installation instructions, English
Catalogue, English
4)

Workstation Components for Supply Units

Maximum load that can be carried on the supply head or column

As required
100-127 V, 220-240 V, 50-60 Hz
2 possible for beams > 2200 mm

During storage
20 C up to + 60 C
< 100%
90 39 161
90 48 440

HEADQUARTERS

www.draeger.com

REGION EUROPE CENTRAL


AND EUROPE NORTH

REGION MIDDLE EAST, AFRICA,


CENTRAL AND SOUTH AMERICA

Drger Medical GmbH


Moislinger Allee 5355
23558 Lbeck, Germany
Tel +49 451 882 0
Fax +49 451 882 2080
info@draeger.com

Drger Medical GmbH


Branch Office Dubai
Dubai Healthcare City
P.O. Box 505108
Dubai, United Arab Emirates
Tel + 971 436 24 762
Fax + 971 436 24 761
contactuae@draeger.com

REGION EUROPE SOUTH

REGION ASIA / PACIFIC

Drger Mdical S.A.S.


Parc de Haute Technologie dAntony 2
25, rue Georges Besse
92182 Antony Cedex, France
Tel +33 1 46 11 56 00
Fax +33 1 40 96 97 20
dlmfr-contact@draeger.com

Draeger Medical South East Asia Pte Ltd


25 International Business Park
#04-27/29 German Centre
Singapore 609916, Singapore
Tel +65 6572 4388
Fax +65 6572 4399
asia.pacific@draeger.com

CANADA

Draeger Medical Canada Inc.


120 East Beaver Creek Road Suite 104
Richmond Hill Ontario L4B 4V1
Tel +1 905 763 3702
Toll-free +1 866 343 2273
Fax +1 905 763 1890
Canada.Support@draeger.com

Manufacturer:
Drger Medical GmbH
23542 Lbeck, Germany
The quality management system at
Drger Medical GmbH is certified according to ISO 13485, ISO 9001 and
Annex II.3 of Directive 93/42/EEC
(Medical devices).

90 51 512 | 09.10-5 | Marketing Communications | LSL | LE | Printed in Germany | Chlorine-free environmentally compatible | Subject to modifications | 2010 Drgerwerk AG & Co. KGaA

Drgerwerk AG & Co. KGaA


Moislinger Allee 5355
23558 Lbeck, Germany

You might also like