You are on page 1of 18

Passive house detail 0.1.

1
Design of plinth area with projecting facade
insulation and perimeter insulation
down to foundation

interior plaster
brickwork
bonding
ETICS Insulation Board
ETICS Basecoat + Finishing Coat
in system build-up
260

175

ETICS Plinth Joint Profile


ETICS Window Joint Profile
300

Fill with PUR Filler Foam without joints


ETICS Plinth and Underground Insulation Board,
bonded with ETICS Multiflex
ETICS Basecoat + Finishing Coat
in system build-up
double protection coat using
ETICS Multiflex
foundation wall protection foil
existing water proofing*
capillary-breaking, water draining layer, e.g. gravel

220

*according to DIN 18195

Date: 2009-07-01

Schematic view

Vertical section

10

Passive house detail 0.1.2


Design of plinth connected to soil

bonding
interior plaster

ETICS Insulation Board


ETICS Basecoat + Finishing Coat
in system build-up

brickwork
260

175

10
screed on isolation layer/
steam barrier
thermal insulation

existing water proofing*


300

existing water proofing*

50

basement ceiling

250

double protection coat


using ETICS Multiflex
insulation stone
mortar bed

200

ETICS Plinth and Underground


Insulation Board, bonded with
ETICS Multiflex
foundation wall protection foil
200

unheated basement

*according to DIN 18195

Date: 2009-07-01

Schematic view

Vertical section

Passive house detail 0.1.3


Skirting design with
connection to base plate

260

175

10

bonding
interior plaster
ETICS Insulation Board
ETICS Basecoat + Finishing Coat
in system build-up

brickwork
screed on isolation layer/
steam barrier
thermal insulation

existing water proofing*


300

existing water proofing*


base plate

50

compensation layer

250

double protection coat


using ETICS Multiflex

200

foundation wall protection foil

insulation stone
mortar bed

drainage

fillet
ETICS Plinth and Underground Insulation Board,
bonded with ETICS Multiflex

*according to DIN 18195

Date: 2009-07-01

Schematic view

Vertical section

Passive house detail

0.2

Connection to balcony exit sill

ETICS Sealing Tape


balcony exit sill

ETICS Sealing Tape


airtight window connection foil
ETICS Basecoat + Finishing Coat
in system build-up
supporting console
double protection coat using ETICS Multiflex
foundation wall protection foil
ETICS Plinth and Underground Insulation Board,
bonded with ETICS Multiflex

Date: 2009-07-01

260

Schematic view

175

Vertical section

Passive house detail 0.3.1


System connection to
windows flush with facade

ETICS Window Sill

30

ETICS Window Joint Profile, Special+

airtight window
connection foil

260

ETICS Basecoat + Finishing Coat


in system build-up

175

10

brickwork

ETICS Insulation Board

interior plaster

bonding

Date: 2009-07-01

Schematic view

Vertical section

Passive house detail 0.3.2


System connection to
semi-attached windows

ETICS Window Sill


ETICS Window Joint Profile, Special+
30

airtight window
connection foil

260

ETICS Basecoat + Finishing Coat


in system build-up

175

10

brickwork

ETICS Insulation Board

interior plaster

bonding

Date: 2009-07-01

Schematic view

Horizontal section

Passive house detail 0.3.3


System connection to
attached windows

ETICS Window Sill


ETICS Window Joint Profile, Special+
30

airtight window
connection foil

ETICS Insulation Board


260

ETICS Basecoat + Finishing Coat


in system build-up

10

brickwork

bonding

Date: 2009-07-01

175

interior plaster

Schematic view

Horizontal section

Passive house detail 0.3.4


Inclined reveal connection to
attached windows

30

ETICS Window Joint Profile, Special+


airtight window
connection foil

260
ETICS Basecoat + Finishing Coat
in system build-up

175

10

brickwork

ETICS Insulation Board

interior plaster

bonding

Date: 2009-07-01

Schematic view

Horizontal section

Passive house detail 0.4.1


System connection ETICS window sill to
windows flush with facade

ETICS Sealing Tape


ETICS Window Sill
ETICS Sealing Tape
airtight window connection foil
ETICS Wall Anchor
ETICS Insulation Board
ETICS Basecoat + Finishing Coat
in system build-up

Date: 2009-07-01

260

Schematic view

175

10

Vertical section

Passive house detail 0.4.2


System connection ETICS window sill to
semi-attached windows

ETICS Sealing Tape


ETICS Window Sill
ETICS Sealing Tape
assembly base
ETICS Wall Anchor
airtight window connection foil
ETICS Insulation Board
ETICS Basecoat + Finishing Coat
in system build-up

Date: 2009-07-01

260

Schematic view

175

10

Vertical section

Passive house detail 0.4.3


System connection ETICS window sill to
attached windows

ETICS Sealing Tape


ETICS Window Sill
ETICS Sealing Tape
assembly base
ETICS Wall Anchor
airtight window connection foil
ETICS Insulation Board
ETICS Basecoat + Finishing Coat
in system build-up

Date: 2009-07-01

260

Schematic view

175

10

Vertical section

Passive house detail 0.5.1


Exterior corner

260

175

10

interior plaster
brickwork
bonding
ETICS Insulation Board

260

175

10

ETICS Basecoat + Finishing Coat


in system build-up

Date: 2009-07-01

Schematic view

Horizontal section

Passive house detail 0.5.2


Interior corner

10

175

260

interior plaster
brickwork
bonding
ETICS Insulation Board

10

175

260

ETICS Basecoat + Finishing Coat


in system build-up

Date: 2009-07-01

Schematic view

Horizontal section

Passive house detail 0.6.1


Interior wall/exterior wall

interior plaster
brickwork
bonding
ETICS Insulation Board

10

115

10

ETICS Basecoat + Finishing Coat


in system build-up

interior plaster
brickwork
260

Date: 2009-07-01

Schematic view

175

10

Horizontal section

Passive house detail 0.6.2


Intermediate floor/exterior wall

interior plaster
brickwork

bonding
ETICS Insulation Board

10

200

20

50

ETICS Basecoat + Finishing Coat


in system build-up

interior plaster
brickwork
260

Date: 2009-07-01

Schematic view

175

10

Vertical section

Passive house detail 0.7.1


Connection to attic

sheet metal flashing, 2 % inclination

ETICS Sealing Tape

ETICS Sealing Tape


bitumen seal, double
steam barrier/emergency seal

50

concrete ceiling

350

bonding
ETICS Insulation Board

10

200

ETICS Basecoat + Finishing Coat


in system build-up

interior plaster
brickwork
260

Date: 2009-07-01

Schematic view

175

10

Vertical section

Passive house detail 0.7.2


Upper system connection to pitched roof

30

chipboard 20 mm

22
240
60
12,
5

intermediate
rafter insulation
air seal

embed air seal in plaster

sub-rafter insulation
with installation level
gypsum plasterboard

20

50

ETICS Sealing Tape

200

bonding

10

ETICS Insulation board


ETICS Basecoat + Finishing Coat
in system build-up
interior plaster
brickwork
260

Date: 2009-07-01

Schematic view

175

10

Vertical section

Passive house detail 0.7.3


Upper system connection to
verge with verge tile

verge tile

22

ETICS Sealing Tape

12,5

58

240

formwork

embed air seal in plaster

intermediate
rafter insulation
bonding

air seal

ETICS Insulation Board

sub-rafter insulation
with installation level

ETICS Basecoat + Finishing Coat


in system build-up

gypsum plasterboard
interior plaster
brickwork
260

Date: 2009-07-01

Schematic view

175

10

Vertical section

You might also like