You are on page 1of 5

Project: Bermuda Villas

AS PER HEAT LOAD CALCULATIONS


REQUIREMENT

SPECIFIED CONDITIONS
SN.

Location

UNIT TYPE

TMBH
(NOM)

CFM

QTY

TMBH

SMBH

DCFM

TR

VILLA TYPE - A [ 5 VILLAS]

AC-GF-FCU-01

Ducted

18

480

17.99

15.8

685

1.499

AC-GF-FCU-02

Ducted

18

640

17.46

16.36

779

1.455

AC-GF-FCU-03

Ducted

32

640

30.9

25.29

981

2.575

AC-GF-FCU-04

Ducted

72

1920

67.36

61

2757

5.613

AC-GF-FCU-05

Ducted

60

1600

55.28

51.44

2426

4.607

AC-FF-FCU-01

Ducted

18

480

19.06

17.97

862

1.588

AC-FF-FCU-02

Ducted

24

480

25.41

24.31

1189

2.118

AC-FF-FCU-03

Ducted

12

480

13.04

11.94

551

1.087

AC-FF-FCU-04

Ducted

24

640

11.2

10.83

494

0.933

10

AC-FF-FCU-05

Ducted

36

960

29.84

28.75

1418

2.487

11

AC-FF-FCU-06

Ducted

32

800

28.9

27.25

588

2.408

55
Note:
1. Selected Capacities are based on the following conditions:
Entering Air Temperature 70 F (21.1 C) DB / 60 F (15.60 C) WB
Design conditions selected based on 27/19 air on coil & 46 deg C ambient temp.
Apparatus dew point temperature 55 deg F, Bypass factor 0.1
Ambient Temperature 115 F
Refrigerent Type: R-407 C

FIT-410.01 R0 D01/06/2010

Project: Bermuda Villas

AS PER HEAT LOAD CALCULATIONS


REQUIREMENT

SPECIFIED CONDITIONS
SN.

Location

UNIT TYPE

TMBH
(NOM)

CFM

QTY

TMBH

SMBH

DCFM

TR

VILLA TYPE - B [ 20 VILLAS]

AC-GF-FCU-01

Ducted

18

480

20

14.62

13.72

896

1.22

AC-GF-FCU-02

Ducted

18

480

20

15.78

15.33

1001

1.32

AC-GF-FCU-03

Ducted

24

640

20

22.88

20.84

1361

1.91

AC-GF-FCU-04

Ducted

60

1600

20

63.15

61.8

4037

5.26

AC-GF-FCU-05

Ducted

36

960

20

38.1

36.06

2355

3.18

AC-FF-FCU-01

Ducted

30

800

20

27.97

27.52

1798

2.33

AC-FF-FCU-02

Ducted

24

640

20

20.23

19.78

1292

1.69

AC-FF-FCU-03

Ducted

30

800

20

27.27

26.82

1752

2.27

AC-FF-FCU-04

Ducted

36

1120

20

38.71

38026

2499

3.23

10

AC-FF-FCU-05

Ducted

36

1120

20

38.23

37.1

2423

3.19

200
Note:
1. Selected Capacities are based on the following conditions:
Entering Air Temperature 70 F (21.1 C) DB / 60 F (15.60 C) WB
Apparatus dew point temperature 55 deg F, Bypass factor 0.1
Ambient Temperature 115 F
Refrigerent Type: R-407 C

FIT-410.01 R0 D01/06/2010

Project: Bermuda Villas

AS PER HEAT LOAD CALCULATIONS


REQUIREMENT

SPECIFIED CONDITIONS
SN.

Location

UNIT TYPE

TMBH
(NOM)

CFM

QTY

TMBH

SMBH

DCFM

VILLA TYPE - C [23 VILLAS]

AC-GF-FCU-01

Ducted

18

480

23

14.62

13.72

896

1.22

AC-GF-FCU-02

Ducted

18

480

23

15.78

15.33

1001

1.32

AC-GF-FCU-03

Ducted

24

640

23

22.88

20.84

1361

1.91

AC-GF-FCU-04

Ducted

72

1600

23

63.15

61.8

4037

5.26

AC-GF-FCU-05

Ducted

36

960

23

38.1

36.06

2355

3.18

AC-FF-FCU-01

Ducted

24

800

23

14.22

13.12

612

1.19

AC-FF-FCU-02

Ducted

18

480

23

18.66

17.56

841

1.56

AC-FF-FCU-03

Ducted

42

1120

23

23.82

22.72

1107

1.99

AC-FF-FCU-04

Ducted

48

1280

23

31.47

27.62

1198

2.62

207
Note:
1. Selected Capacities are based on the following conditions:
Entering Air Temperature 70 F (21.1 C) DB / 60 F (15.60 C) WB
Apparatus dew point temperature 55 deg F, Bypass factor 0.1
Ambient Temperature 115 F
Refrigerent Type: R-407 C

FIT-410.01 R0 D01/06/2010

Project: Bermuda Villas

AS PER HEAT LOAD CALCULATIONS


REQUIREMENT

SPECIFIED CONDITIONS
SN.

Location

UNIT TYPE

TMBH
(NOM)

CFM

QTY

TMBH

SMBH

DCFM

TR

VILLA TYPE - C [ 61 VILLAS]

AC-GF-SP-01

Split

160

61

8.04

6.94

293

0.67

AC-GF-FCU-02

Ducted

24

640

61

29.59

27.39

1283

2.47

AC-GF-FCU-03

Ducted

72

1920

61

61.4

57

2681

5.12

AC-FF-FCU-01

Ducted

36

960

61

30.75

29.11

1404

2.56

AC-FF-FCU-02

Ducted

42

1120

61

45.34

42.05

1974

3.78

AC-FF-FCU-03

Ducted

18

480

61

16.51

15.42

730

1.38

366
Note:
1. Selected Capacities are based on the following conditions:
Entering Air Temperature 70 F (21.1 C) DB / 60 F (15.60 C) WB
Apparatus dew point temperature 55 deg F, Bypass factor 0.1
Ambient Temperature 115 F
Refrigerent Type: R-407 C

FIT-410.01 R0 D01/06/2010

Project: Bermuda Villas

AS PER HEAT LOAD CALCULATIONS


REQUIREMENT

SPECIFIED CONDITIONS
SN.

Location

UNIT TYPE

TMBH
(NOM)

CFM

QTY

TMBH

SMBH

DCFM

TR

VILLA TYPE - C [ 48 VILLAS]

AC-GF-FCU-01

Split

12

320

48

10.95

9.85

443

0.91

AC-GF-FCU-02

Ducted

42

1280

48

58.66

53.17

2418

4.89

AC-FF-FCU-01

Ducted

18

480

48

17.6

16.5

786

1.47

AC-FF-FCU-02

Ducted

30

800

48

22.81

17.87

630

1.90

AC-FF-FCU-03

Ducted

24

640

48

24.96

22.77

1045

2.08

240
Note:
1. Selected Capacities are based on the following conditions:
Entering Air Temperature 70 F (21.1 C) DB / 60 F (15.60 C) WB
Apparatus dew point temperature 55 deg F, Bypass factor 0.1
Ambient Temperature 115 F
Refrigerent Type: R-407 C