You are on page 1of 30

Parameter Name

FDD Qmin

Meaning

Feature Name

This parameter specifies one of the parameters


for FDD cell reselection.
A FDD cell becomes a candidate cell if all the
following conditions are met for five consecutive
seconds:
1.Receive level of the FDD cell > Average receive
level of the current serving cell + "FDD Q offset";
The FDD cell meets the following condition in the
case of any neighboring 2G cell: Receive level of
the FDD cell > Receive level of any neighboring
2G cell + "FDD Q offset";
2. Ec/No of the FDD cell > "FDD Qmin" - "FDD
Qmin Offset";
3. Receive level of the FDD cell > "RSCP
Threshold";
If multiple FDD cells meet the preceding
conditions, the MS reselects the cell with the
strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the
following decibel values:
0: -20 dB,
1: -6 dB,
2: -18 dB,
3: -8 dB,
4: -16 dB,
5: -10 dB,
6: -14 dB,
GSM/WCDMA
7: -12 dB.
Interoperability

FDD Q Offset

This parameter specifies one of the thresholds of


the signal level for 3G cell reselection.
A FDD cell becomes a candidate cell if all the
following conditions are met for five consecutive
seconds:
1.Receive level of the FDD cell > Average receive
level of the current serving cell + "FDD Q offset";
The FDD cell meets the following condition in the
case of any neighboring 2G cell: Receive level of
the FDD cell > Receive level of any neighboring
2G cell + "FDD Q offset";
2. Ec/No of the FDD cell > "FDD Qmin" - "FDD
Qmin Offset";
3. Receive level of the FDD cell > "RSCP
Threshold";
If multiple FDD cells meet the preceding
conditions, the MS reselects the cell with the
strongest receive level.
See 3GPP TSs 45.008 and 25.304.
The values of this parameter correspond to the
following decibel values:
0: - (always select a cell if acceptable)
1: -28 dB,
2: -24 dB,
...
GSM/WCDMA
15: 28 dB.
Interoperability

Qsearch I

BSC6900

SET
GCELLCCUTRANS
YS(Optional)

Qsearch P

BSC6900

SET
GCELLCCUTRANS
YS(Optional)

FDD Qmin Offset

BSC6900

SET
GCELLCCUTRANS
YS(Optional)

Actual Value Range

-20, -6, -18, -8, -16, -10, -14, -12 dB

Unit

Recommended Value

Impact

0 Cell

Negative infinity, -28~28, step: 4 dB

8 Cell

The values of this parameter


correspond to the following
decibel values:
0: -98 dBm
1: -94 dBm
2: -90 dBm
3: -86 dBm
4: -82 dBm
5: -78 dBm
6: -74 dBm
7: (always), that is, the MS
keeps searching for 3G cells
8: -78 dBm
9: -74 dBm
10: -70 dBm
11:
-66 dBm
12: -62 dBm
13: -58 dBm
14:
-54 dBm
15: Positive
infinity(never), that is, the MS
does not search for 3G cells

GBFD114301
GBFD114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA
Interval
Interoperability
Type

example, if this parameter is set


to 5 and if the signal level of the
serving cell is lower than 5, the
MS starts to search for 3G cells;
if this parameter is set to 10 and
if the signal level of the serving
cell is above 10, then the MS
starts to search for 3G cells.
The
values of this parameter
correspond to the following
decibel values:
0: -98 dBm

1: -94 dBm
...
6: -74 dBm
7: (always)
8:
-78 dBm
9: -74 dBm
...
14: -54 dBm

GBFD114301
GBFD114302

GSM/WCDMA Interoperability
GSM/TD-SCDMA
Interval
Interoperability
Type

Offset of the minimum threshold


for Ec/No during a FDD cell
reselection.
A FDD cell becomes a candidate
cell if all the following conditions
are met for five consecutive
seconds:
1.Receive level of the FDD cell >
Average receive level of the
current serving cell + "FDD Q
offset";
The FDD cell meets the following
condition in the case of any
neighboring 2G cell: Receive
level of the FDD cell > Receive
level of any neighboring 2G cell +
"FDD Q offset";
2. Ec/No of the FDD cell > "FDD
Qmin" - "FDD Qmin Offset";
3. Receive level of the FDD cell >
"RSCP Threshold";
If multiple FDD cells meet the
preceding conditions, the MS
reselects the cell with the
strongest receive level.
See 3GPP TSs 45.008 and
GBFD25.304.
114301

Interval
GSM/WCDMA Interoperability Type

Parameter Relationship

Access

Service Interrupted After Modification

This parameter is valid only when


the
""INTERRATCELLRESELEN""
parameter regarding the "SET
GCELLHOBASIC" command is
set to YES.
Read & Write N (No impact on the UE in idle mode)

None

Read & Write N (No impact on the UE in idle mode)

0~15

-98, -94, -90,


-86, -82, -78,
-74, (always),
-78, -74, -70,
-66, -62, -58,
-54, Positive
infinity(never) None

0~15

-98, -94, -90,


-86, -82, -78,
-74, (always),
-78, -74, -70,
-66, -62, -58,
-54, Positive
infinity(never) None

0~7

0~7

dB

Interruption Scope

Not involved

Interruption Duration(Min)

Not involved

Caution

None

Validation of Modification

The parameter modification has no


impact on the equipment.

Not involved

Not involved

None

The parameter modification has no


impact on the equipment.

15

15 Cell

None

15

15 Cell

None

0 Cell

None

Impact on Radio Network Performance

None

Introduced in Version

Versions earlier than


BSC6900 V900R011

Attribute

Radio

None

Versions earlier than


BSC6900 V900R011

Radio

Read & Write

N (No impact on the UE in idle


Not
mode)
Not involved involved

Read & Write

N (No impact on the UE in idle


Not
mode)
Not involved involved

Read & Write

N (No impact on the UE in idle


Not
mode)
Not involved involved

None

The
parameter
modification
has no impact
on the
equipment.
None

Versions
earlier than
BSC6900
V900R011

Radio

None

The
parameter
modification
has no impact
on the
equipment.
None

Versions
earlier than
BSC6900
V900R011

Radio

None

The
parameter
modification
has no impact
on the
equipment.
None

Versions
earlier than
BSC6900
V900R011

Radio