You are on page 1of 5

PFENGINE

PNF
START FAULT

STALL

A320 - Version 05a

PF

PNF
1. ENG 2 START FAULT

Apply before start procedure


Start engine 2
DETECTION
ECAM ACTIONS
ECAM PROCEDURE
SYSTEM DISPLAY
STATUS

DECISION
PF
COMMUNICATES

ST AT US, or
SUMM ARY

WE ATHER
WEATHER
LDG DIS T
LDG DIST
OPERATIONAL
OPERATIONALAND
AND
COMME RCIAL
COMMERCIAL
CONSIDERATIONS
CONS
IDERATIONS

ATC
ATC
DECISION
DECISIO N
NOT IFY

PURSER
PURSER/ PAX
/ PAX
OPS
OPS

PF

ACTIONS PERFORMED BY THE FADECPNF

The FADEC automatically :


shuts off the fuel
turns off the ignition
Note: The start valve
remains open

Automatic new start : the FADEC


attempts to restart the engine three
more times, reducing the fuel
schedule in stages

If the engine doesnt start, the


ECAM asks the pilot to confirm the
automatic start abort by setting
ENG MASTER 2 to OFF.

Note: This time, both


igniters are powered

PF

ECAM PROCEDURE

PNF

Do not interrupt the FADEC protective actions

The FADEC automatically


abort the start sequence

The fault light turns off when the


engine master switch is set to OFF

PF

PNF

DECISION
Review FCOM 3.02 procedure (If time permits)

Then, 2 options :
Ask for appropriate maintenance actions

FCOM

Perform a new start attempt (prefer manual start procedure)


3.04.70

Starter engagement is limited in time and in number of successive attempts :


Start cycle

2 min

2 min
20
Pause

2 min
20

2 min
20

No running engagement of the starter when the N2 is above 20%

Starter cool down


15 min