Hidupkan Site Master a. Di Menu Mode, pilih Freq. Masukkan F1=1770 Mhz dan F2=1880 Mhz b. Di Menu Mode, pilih Distance to Fault. Masukkan D1=0 m dan D2=60 m (Untuk tinggi Antenna 50 m) c. Tekan START CAL di tombol depan Site Master d. Hubungkan konektor SHORT ke port kalibrasi Site Master lalu tekan ENTER e. Hubungkan konektor OPEN ke port kalibrasi Site Master lalu tekan ENTER f. Hubungkan konektor LOAD ke port kalibrasi Site Master lalu tekan ENTER g. Tekan SAVE untuk menyimpan settingan kalibrasi nya
circutor max12-This manual is an easy guide for the use and operation of the Computer max 6/max 12. For more information, the complete manual can be downloaded from the web site of Circutor: www.circutor.es Any manipulation or use of the equipment out of the conditions specified by the manufacturer may put in risk the user safety. Before any maintenance operation the equipment must be disconnected from power supply. In case of miss operation or protection fault the equipment must be disconnected from supply and remain out of service ensuring against any