OTDR Report

Job ID
Contractor
Customer
Test Date

: umuahia
:
: MTNN
: 3/3/2009 (2:52:08 PM)

Fiber ID
Location A
Cable Mfr.
Subset ID

: 01
: nipost
:
:

Link Loss
Link Length
Average Loss

: 19.078 dB
: 56.6056 km
: 0.337 dB/km

Job Info

Reason
Operator A
Operator B
File

:
:
:
: 004.trc

Cable Info

Cable ID
Location B
Type
Color ID

: 16smf
: oax37
:
:

Link Measurements

Avg. Splice Loss


Max. Splice Loss
Total ORL

: 0.039 dB
: 0.219 dB
: <20.50 dB

OTDR Trace
dB
40.00

1
35.00

30.00

25.00

20.00

3
4

15.00

5
6
7

10.00

8
9

5.00

0.00

10

20

30

40

50

km

OTDR Report
Events Table
No.

Loc.
(km)

0.0000

11.4539

14.5127

23.4644

26.4670

35.4136

41.3167

44.3653

56.6056

Event Type
Launch Level
Fiber Section (11.4539 km)
Non-Reflective Fault
Fiber Section (3.0588 km)
Non-Reflective Fault
Fiber Section (8.9517 km)
Positive Fault
Fiber Section (3.0026 km)
Non-Reflective Fault
Fiber Section (8.9466 km)
Non-Reflective Fault
Fiber Section (5.9031 km)
Positive Fault
Fiber Section (3.0486 km)
Non-Reflective Fault
Fiber Section (12.2403 km)
Reflective Fault

A
a
A to B Distance
A to B LSA Loss
2-pt. Ev. Loss

:
:
:
:
:

0.0000 km, 35.000 dB


N/A
0.0000 km
0.000 dB
0.000 dB

Wavelength
Filename
Hardware
Serial Number
Software
Range
IOR
RBS

:
:
:
:
:
:
:
:

1310 nm (SM-9m)
004.trc
FTB-7200D-023B-EI
388976
N/A
60.0 km
1.46770
-79.44

Loss
(dB)

Refl.
(dB)

--3.748
0.047
1.018
0.026
2.945
-0.072
0.991
0.219
2.930
0.067
2.037
-0.098
1.009
0.084
4.128
---

>-21.0

Marker Info

B
b
A to B LSA Att.

Test and Cable Setup

Acq. Time
Pulse Width
Helix Factor
Splice Loss Threshold
Reflectance Threshold
End-of-Fiber Threshold

Att.
(dB/km)
0.327
0.333
0.329
0.330
0.327
0.345
0.331
0.337

-14.9

: 0.0000 km, 35.000 dB


: N/A
: 0.000 dB/km

:
:
:
:
:
:

15 s
1.0 s
0.00 %
0.020 dB
-72.0 dB
5.000 dB

Cumul.
(dB)
0.000
3.748
3.795
4.813
4.838
7.783
7.711
8.703
8.922
11.851
11.918
13.955
13.857
14.866
14.950
19.078