You are on page 1of 2

OTDR Report

Job ID
Contractor
Customer
Test Date

: umuahia
:
: MTNN
: 3/3/2009 (2:55:35 PM)

Fiber ID
Location A
Cable Mfr.
Subset ID

: 01
: nipost
:
:

Link Loss
Link Length
Average Loss

: 1.890 dB
: 5.5406 km
: 0.341 dB/km

Job Info

Reason
Operator A
Operator B
File

:
:
:
: 006.trc

Cable Info

Cable ID
Location B
Type
Color ID

: 16smf
: oax37
:
:

Link Measurements

Avg. Splice Loss


Max. Splice Loss
Total ORL

: --: --: <20.56 dB

OTDR Trace
dB
40.00

35.00

30.00

25.00

2
20.00

15.00

10.00

5.00

0.00

10

20

30

40

50

km

OTDR Report
Events Table
No.

Loc.
(km)

0.0000

Event Type
Launch Level
Fiber Section (5.5406 km)
Non-Reflective Fault

5.5406

A
a
A to B Distance
A to B LSA Loss
2-pt. Ev. Loss

:
:
:
:
:

0.0000 km, 35.008 dB


N/A
0.0000 km
0.000 dB
0.000 dB

Wavelength
Filename
Hardware
Serial Number
Software
Range
IOR
RBS

:
:
:
:
:
:
:
:

1310 nm (SM-9m)
006.trc
FTB-7200D-023B-EI
388976
N/A
60.0 km
1.46770
-79.44

Loss
(dB)

Refl.
(dB)

--1.890
---

>-20.9

Marker Info

B
b
A to B LSA Att.

Test and Cable Setup

Acq. Time
Pulse Width
Helix Factor
Splice Loss Threshold
Reflectance Threshold
End-of-Fiber Threshold

Att.
(dB/km)

Cumul.
(dB)

0.341

0.000
1.890
1.890

: 0.0000 km, 35.008 dB


: N/A
: 0.000 dB/km

:
:
:
:
:
:

15 s
1.0 s
0.00 %
0.020 dB
-72.0 dB
5.000 dB