You are on page 1of 7
SAMKO Q07-14-M-YP-0655-09 22 August 2009 MIDMAC CONTRACTING Co, W.L.L. P.O BOX 1758 DOHA QATAR ‘Attn: Mr. JACK GHANTOUS PROJECT DIRECTOR ‘Subj. : AL SAD DEVELOPMENT COMPLEX -528 PROJECT ELECTROMECHANICAL WORKS ‘TOWERS MAIN PPRC RISER PIPE SUPPORTS. Dear Sir, Please find enclosed herewith Towers Main PPRC Riser Pipe Supports Calculation for Al Sadd Development Complex project for approval. Yours faithfully, Omet Kucuk Projelft Manager AL-SADD COMPLEX TOWERS MAIN PPRC RISER PIPE SUPPORTS CALCULATION Rev 0 SAMKO SAMKO INTERNATIONAL CO WLL 21" AUG 2009 By. Yuksel POLAT 1200 ho | 520 (Lok ih MAIN SUPPORTS GUIDING |_ SUPPORTS 7 Miso anchors CLAMP s 2 3 8 | 50x50x3 Angle bar 50 Ly ae VA, “1 31 8 HILT! ey KH SS CLAMP To = a 8 2 et | UL L-U-Bolt M10 i * : $3 | 200x200x10mm plate feat with 4 hole for M12 anchor SSC CHANNEL + | BOXBOx5O- 1109 to SODPPR “4| 110 PPRC Up fo roof From Roof fo ground le ~ “| (constant size) (variable size) - 5kg water/m+4.6kg/m =9.6kg/m pipe weight TOWERS TYPICAL PLUMBING RISER PIPE SUPPORT DETAIL | j 1 VERIFICATION OF C CHANNEL 50x80x50 -8mm web thickness i 1.2m 0.68m, 0.43m 0.25m 0.52m | U Ae U 40kg 40kg (FOR STRENGTH CALCULATION SEE ATTACHED EXCEL DATA SHEET) VERIFICATION OF ANCHOR PLATE 200x200x10mm | FOR ANCHOR PLATE AND ANCHORS NO NEED DETAIL CALCULATION BECAUSE OF ONLY SHEAR FORCE ACTS ON ANCHOR: Total Shear Load is 80 kg. No of anchors are 8 pos Shear load per anchore=10kg Anchor Yield point 235N/imm . With 1.6 safety coefficient , Safety stress is 145N/mm2 M40 or M12 anchor is more safe VERIFICATION OF HILT! 4"CLAMP AT VERTICAL POSITION PIPE LOADS ARE BEING CARRIED BY 3°CHANNEL SUPPORTS. 50x50 ANGLE SUPPORTS ARE NOT CARRYING THE LOAD. BUT SAFETY PURPOSES WE CAN ASSUME EACH CLAMP CARRY im DN100 PIPE WEIGHT . LOAD=10kg Design safe Load of HILT! Clamp MP-HI 4"in vertical is6.9 kg at 155 mm from centerline to wall as per HILT! Calculation .( See attached Page) in our case distance from pipe CL to wall ( Support face) is 75mm , thus safe load capacity of clamp at short distance is 6.9Kg*155/75=14.3 Kg. 4"HILTI Clamp Is Safe “BEAMANAL 2s" Progam (metric version} Version 1.0 SINGLE-SPAN BEAM ANALYSIS For Simple, Propped, Fixed, or Cantilever Beams IMeric Units Version xin) Job Nanne: ACSADD. T Supjock [110 PPROPIPE RISER SUPEORTS ‘Job Number NPU-80 (73x26 CHANNEL) 8 | Orginator |Y Polat | Checker: |¥ Polat Input Data: ¢ Beem Data: ‘Span Type? Ea Span, L=| 4.2000 fm Modulus, E =} 200000) Jupa Thera, |=[." 204 Jems Beam Loadings. Full Uniform [BBE om Start End Distributed:[ bint | won) [eta] wena) * Ry Z| ML to Max. Moments aim) and Locations ink oe a a 0.680, a “Mens =| 0.32 ‘000 e a Max. Dafsetion® fam) and Locations n. =| -ameg=[- 1040] ex-| ae zl aimans =| 0.000 0,000 avec) =[ L183 Point Loads:[ ami [Pia et Gabo oa ma} 16800. | 0.40 ® - % z # 5 an 8 & ze. BF He at LS) oe me “ of : on i i eit Moments:[—eiay_[Wiaay] = °° Fo: e bo. ra * * holt 221082008 16:28 “BEAMANAL xi" Program (metric version) Version 1.0 "Tabulation of Single Span eam Shear, Moment, Slope, and Delleclion for Equal Segments Fon eT xn Moment oom) {Sipe orRotsion ad) Dolaction inp 3) 000 "0000, eres OWN ees Tey oom, : 6.0008 “6.0066 20 Tose boobies 4. [09720 “O.0674 facet} o.ae ma 6 0az00"| ~o.aa tid ~[otaeo 0.44 2 [estes0 | oe z of He20 | Toe 0.0028 10 oo 0.8 “ioe 417 [lonaoo | oa = 6.0007 iz [zea0"| oa : “bi 43 [eZee ~.9028 1 “kio027 15 16 O72 7 “0.7906 18 18 20 24 23 2 2a 25 26 a 28 29 30 34 32 33 34 as 28 a 38 0 39 ~ Bats 40 aes 4 ~o.36e4 a2 Dabo a 2631 = D.2004 z 152t “0.1090 ay “oarie ae “DHt7 a9 | ieee] 0.36 “00181 80} 44760" | 038 “0048 ea | 3000] 0.36 0000 tort 22I08I2008 15:33 Fees % VDE Channed Ea Neca EEE ‘Oui deh (9 - Outside Bange width (12) “Flange thickness 14)

You might also like