Asme Ix Practice Questions: (Closed Book)
Asme Ix Practice Questions: (Closed Book)
2.
essential variables
qualification test & examination results
supplementary essential variables (when notch toughness is
required)
5.
Non-essential variables
Essential variables
Ranges of 1 & 2 above
All of the above
4.
welder is qualified
base metals are strong enough
weldment has the desired properties
skill of the welder
3.
The
The
The
The
1958
1992
1987
1962
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
31
6.
7.
8.
Vertical
Flat & horizontal
Flat & overhead
Horizontal
10.
Manufacturer
Welder
Authorised Inspector
Foreman
9.
Flat only
Flat and horizontal
Flat and vertical
None of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
32
11.
12.
13.
3.5%
0.5%
5%
All of the above
16.
True
False
15.
Tensile strength
Ductility
Notch toughness
All of above
14.
Stud welds
Overhand welds
Fillet welds
All of the above
1/16
3/32
1/8
None of the above
ASME Section V
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
33
B.
C.
D.
17.
18.
Inspector
Manufacturer or contractor
Welder
All of the above
21.
Nonessential variables
Essential variables
Results of Welder Qualification tests
Project description & NDE methods
20.
Essential variables
Nonessential variables
Supplementary essential variable when required for notch
toughness
All of the above
19.
ASME Section IX
ASME Section VII
The referencing code
Groove design
Post Weld Heat Treatment
Root spacing
Method of cleaning
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
34
22.
23.
24.
Without backing
With all base metals
With backing only
With P1 backing only
27.
Yes
No.
26.
PQR
WQR
WPS
WPQ
If a welder qualified with the SMAW process on Jan. 1,1994 and last
welded with SMAW on March 15, 1994, would he still be qualified
on October 7, 1994?
A.
B.
25.
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
35
C.
D.
28.
29.
32.
Electrodes
Flux
Base metals
Joints
31.
8
Max to be welded
1
30.
Essential
Brazing
AWS class
ASME specification
SFA
F number
P number
Welder I.D.
A number
Page number
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
36
33.
For
welder
qualifications
with
the
SMAW
______________________ is an essential variable.
A.
B.
C.
D.
34.
Yes
No
Not enough information provided
Yes, provided pipe is carbon steel, P#1
37.
P number
Unique identifier
Hood & gloves
Inspector
36.
35.
process
A welder has been tested in the 6-G position, using as E-7018 F-4
electrode, on 6 Sch 160 (0.718 nom) SA 106B pipe. Is this welder
qualified to weld a 2 300# ANSI schedule 80 bore flange to a 2
Schedule 80 SA 106 B nozzle neck?
A.
B.
C.
D.
Yes
No
Not enough information provided
Yes, provided a backing strip is provided in the 2 weld.
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
37
38.
Yes
No
Not enough information provided
Yes, because backing is not an essential variable for a welder
39.
40.
41.
43.
Inspector
A.I.
Shop Foreman
Manufacturer of Contractor
42.
The
The
The
The
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
38
True
44.
and
and
and
and
4G
5G
1G
5G
ASME
ASME
ASME
ASME
Section
has
welding
electrode
storage
IX
VIII
B31.1
II Part C
48.
3G
2G
3G
4G
47.
2
4
6
3
What positions are necessary to qualify a welder for all position pipe
welding?
A.
B.
C.
D.
46.
45.
Or
Yes
No
Not enough information given
Yes, if properly heat treated
Yes
No
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
39
C.
D.
49.
50.
Yes
No, must be re-qualified
Is only applicable for 1965 pressure vessels
Cannot be used for new construction repairs only
What are the various positions in which a welder may qualify for
plate groove welds?
A.
B.
C.
D.
53.
Yes
No
Not enough information provided
None of the above
52.
A welder was qualified with a P-1 test coupon using SMAW E 7018
electrodes. May the welder weld P-4 material using E8028
electrodes with backing in production? (Assume the P-4 procedure
using E8028 electrodes has been qualified)
A.
B.
C.
D.
51.
1G
3G
4G
All of the above
You are reviewing a WPQ (QW-484) for a welder testing in the 6-G
position, on SA-53 grade B pipe (TS-60,000 psi). The test results
indicate the following:
No.1
No.2
No.1
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
40
No.2
55.
F,H,OH
F,V,OH
V,OH,SP
H,V,OH
57.
56.
Yes
No
Not enough information given
Tension test is acceptable but No.1 is unacceptable
E6010
E7018
E9028
All of the above
The WPS
The PQR
The WPQ
All of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
41
58.
59.
60.
Essential variable
Non-essential variable
Supplementary essential variable
All of the above
62.
Porosity, underfill
Lack of penetration/fusion
Slag, overlap
Any of the above
61.
5G and 6G
2G and 4F
4G and 5G
None of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
42
63.
64.
D.
Or
and,
if
applicable,
68.
5X
2X
10X
No magnification is required visual examination is required,
only
67.
(circle one)
66.
False
When using Macro-examination of fillet weld tests, the weld and the
HAZ must not reveal cracks when magnified at:
A.
B.
C.
D.
65.
or
The AI approves
The test data on a PQR is a record of what occurred and
should never be changed. Only editorial information can be
changed on a PQR.
The API 510 inspector approves
The date of the WPS is changed
or
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
43
69.
70.
71.
Or
Or
75.
Or
74.
73.
Or
72.
Pass
Fail
SMAW
qualification
is
Essential
Non-essential
Supplemental essential
None of the above
procedure
SAW
procedure
qualification
is
an
Essential
Non-Essential
Supplemental essential
None of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
44
76.
77.
Or
Or
83.
Or
82.
81.
Or
80.
Essential
Non-essential
Supplemental essential
None of the above
79.
78.
Or
Or
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
45
A.
B.
C.
D.
E.
84.
85.
The maximum preheat temperature decrease allowed without requalification of a GMAW groove weld procedure is:
A.
500F
B.
1000F
C.
1250F
D.
1500F
E.
None of the above
A welder is qualified to weld all thick nesses of material when:
A.
B.
C.
D.
86.
inch
1/8 inch
1/16 inch
3/16 inch
No defects are allowed
88.
87.
1G
2G
5G
6G
All of the above
3 months
6 months
9 months
12 months
As stated by the AI
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
46
A.
B.
C.
D.
E.
89.
90.
B.
C.
D.
E.
92.
E7015
E6011
E6010
E7024
All of the above
91.
Designer or architect
Designer or installer
Architect or installer
Installer or assembler
Assembler or designer
For
P-11
materials,
weld
grooves
for
thick
nesses
________________ shall be prepared by thermal processes, when
such processes are to be employed during fabrication.
A.
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
47
B.
C.
D.
E.
93.
94.
2 inches
21/2 inches
3 inches
31/2 inches
4 inches
97.
Or
96.
95.
5/8 inch
1 inch
11/4 inches
None of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
48
C.
D.
98.
Two plate tensile test specimens have been tested and found to be
acceptable. The characteristics of each specimen are as follows:
Specimen 1: Width of 0.752; thickness of 0.875; ultimate tensile
value of 78.524 psi
Specimen 2: Width of 0.702; thickness of 0.852; ultimate tensile
value of 77,654 psi
What is the ultimate load for each specimen that was reported on
the laboratory report?
A.
B.
C.
D.
99.
GMAW
SAW
PAW
All of the above
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
49
ANSWER KEY
1. C
2. D
3. D
4. D
5. B
6. B
7. C
8. C
9. D
10.
11.
12.
13.
B
C
C
A
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
C
D
A
C
B
D
D
A
B
A
B
True
D
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
50
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
C
C
B
D
B
B
B
A
B
D
B
C
A
C
C
C
C
D
C
C
B
B
A
B
B
A
D
C
B
B
A
B
D
B
B
C
A
A
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.
98.
99.
C
False
B
False
Pass
True
False
False
False
B
A
True
A
True
False
True
False
True
C
B
C
B
B
E
E
D
D
A
D
False
C
D
A
A
D
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
51
8th Floor, Al-Subeaei Towers, King Abdulaziz cor. Prince Faisal Bin Fahd Streets, Al-Khobar, Saudi Arabia
TEL (966) 3 887 6633 FAX (966) 3 887 6565 info@gotoitc.com www.gotoitc.com
52