Professional Documents
Culture Documents
Shortcut Air Cooled Heat Exchanger Design: Chemical Engineering Calculations
Shortcut Air Cooled Heat Exchanger Design: Chemical Engineering Calculations
CheCalc.com
Process Side
Heat Duty
25.0 MMBTU/h
Overall HTC, U
Process Side
Inlet Temperature
Outlet Temperature
Air Side
Inlet Temperature
Design Face Velocity
Site Elevation
Outlet Temperature
20.0 Deg F
600 ft/min
500 ft
32.83 Deg F
Result
LMTD
Correction Factor
Corrected MTD
14.7 Deg F
0.955
14.05 Deg F
Finned Area
Face Area
Unit Width
Total Tubes
Tubes per Row
4.0 BTU/h.ft2.F
52.0 Deg F
31.0 Deg F
444810 ft2
2766.2 ft2
92.21 ft
2657
443
Tag No.
Description
Date
By
Tube Side
Tube OD
Fin height
Tube Layout
Tube Pitch
Tube Length
Tube Pass
Number of Tube Rows
Drive Power
Fan Efficiency
Motor Efficiency
Air Flowrate
Air Side Pressure Drop
Brake Power
Motor Shaft Power
r Design
E-101
Product Cooler
14/06/14
CheCalc
1.000 inch
0.625 inch
30 Degree
2.500 inch
30.0 ft
Multiple
6
75 %
95 %
1,659,740 ACFM
0.855 inch H2O
297.6 hp
313.3 hp
Process Side
Heat Duty
Overall HTC, U
Process Side
Inlet Temperature
Outlet Temperature
Air Side
Inlet Temperature
Design Face Velocity
Site Elevation
Outlet Temperature
Result
LMTD
Correction Factor
Corrected MTD
Finned Area
Face Area
Unit Width
Total Tubes
Tubes per Row
3.8 MMKcal/h
19.5 Kcal/h.m2.C
121.1 Deg C
65.6 Deg C
37.8 Deg C
3.0 m/s
152 m
74.41 Deg C
36.4 Deg C
0.947
34.48 Deg C
5613 m2
34.9 m2
3.82 m
361
60
Tag No.
Description
Date
By
Tube Side
Tube OD
Fin height
Tube Layout
Tube Pitch
Tube Length
Tube Pass
Number of Tube Rows
Drive Power
Fan Efficiency
Motor Efficiency
Air Flowrate
Air Side Pressure Drop
Brake Power
Motor Shaft Power
r Design
E-101
Product Cooler
14/06/14
CheCalc
1.000 inch
0.625 inch
30 Degree
2.500 inch
9.1 m
Multiple
6
75 %
95 %
383,030 m3/h
19.07 mm H2O
26.1 kW
27.5 kW