You are on page 1of 1

CONCEALED WC FLUSH SYSTEMS

Dimensioning lines/installation dimensions


In order to ensure that the fitting is permanently ready for flushing and, thus, the
required flow pressure, the connecting line must be dimensioned to a minimum
DN 25. The dimensions must be calculated for each object (simultaneity factor)
and pipe material (in accordance with DIN EN 806-3 and the complimentary
national standard DIN 1988-30).

Features of the self-closing cartridge SC

WC flush systems

Core of the concealed WC flush fittings is the self-closing cartridge made from
corrosion-resistant high-grade POM plastic with integrated nozzle cleaning
pin. Single or dual flush self-closing cartridges are available, depending on the
function

Activating adjustment screw

Adjustment screw for flow time


of the main flush
Attachment lug
Piston chamber
Filter
Inflow
Outlet channel

23