Sensitivity of Listeria to XZIOX products in Potable Water

Each litre of potable water spiked with NCTC culture of Listeria


Contact time for all measurements was 5 min

Sample No
1
2

3
4
5
6
7
8
9
10

*mg/l

XZIOX Product
Inoculation level mg/l

Result cfu/l

Sample No

Control
0.1
0.05
0.01
0.005
0.001
0.0005
0.0001
0.00005
0.00001

15600
0
0
8
460
14000
16200
14500
15800
14900

1
2

3
4
5
6
7
8
9
10

is equal to ppm

XZIOX Product 2
Inoculation level mg/l

Result cfu/l

Control
0.1
0.05
0.01
0.005
0.001
0.0005
0.0001
0.00005
0.00001

2100000
0
1
46
660
15500
18000
17000
16000
15500

ALcontrol Laboratories

XZIOX Listeria Rosult

May 2009