membraPure GmbH
Made in Germany
Systems from membraPure – Water purification systems and analyzers for TOC, amino acids and ions
at the highest level.
Since 1993 we have been dealing with water purification systems. In the course of time, we have
continuously expanded our activities to include the associated analyzers like miniTOC, uniTOC, ARACUS
and IONUS. For more than a quarter of a century, membraPure has been an established player in the
market for pure and ultra pure water systems, TOC, amino acid analyzer and ion chromatograph.
We are developing continuously our systems and applications and to applying for patents. In our work,
we exclusively use high-end technology such as EDI, post-column derivatization with ninhydrin and NDIR-
TOC detection.
Our instruments are low-maintenance and enable online service support. We sell our instruments
worldwide via a dealer network and our own sales offices in Beijing/PR China, Kuala Lumpur/Malaysia
and Sao Paulo/Brazil, Mumbai/India.
In 2015, we opened a new manufacturing hall at our headquarters in Hennigsdorf near Berlin to meet
rising demand and to maintain and improve our quality in an even more efficient environment.
Our dedicated team of experts locally and at headquarters in Hennigsdorf/Berlin helps to keep your
systems running smoothly at all times.
Managing Director
Timeline
Water Purification Systems
2
Water Purification Systems
3
Water Purification Systems
1.1 Astacus²
The system Astacus² is designed for the production of ultra pure water
(0.055 μS/cm) out of permeate from a reverse osmosis or deionized
water.
The ultra pure water is produced with a combination of optimized mixed
bed cartridges and can be tapped with a flexible dispenser. If water is not
used, automatic recirculation within the Astacus² system ensures a
permanent high quality of ultra pure water. All components of the
Astacus² are assembled in an especially designed housing. The system
can be easily opened by removing the side panel to access the ultra pure
module, UV lamp (185 nm/ 254 nm) and ultrafiltration module. The μS -
control checks the conductivity of feed water to protect the cartridges
against inappropriate feed water (black line). If conductivity is too high
the water will be rejected.
4
Water Purification Systems
Technical Specifications
ultra pure water quality 0.055 μS/cm; Type I
total organic carbon (TOC) < 10 ppb Reagent | < 5 ppb Life Science | < 3 ppb Analytical
dimensions, weight, power 297 x 340 x 535 mm, 16 - 20 kg, 110 - 230 V
*with Life Science model
temperature 5 to 25 °C
Configurations
Model UV reactor UF module TOC monitoring Cat. No.
Reagent - - - 110-0089
Analytical + - - 110-0090
Analytical TI + - + 110-0092
Reagent BI - - - 110-0099
Analytical BI + - - 110-0095
5
Water Purification Systems
Options
µS-control The μS-control checks the conductivity of feed water to protect 180-0009
the cartridges against inappropriate feed water. If conductivity is
too high the water will be rejected.
TOC monitoring The TOC monitoring during production and intermittent See
(TI version) measurements during non-use periods allows to check the configurations
organic content in water continously between 1 and 999 ppb.
volumetric upgrading of water system to volumetric dispense function 180-0093
dispensing allows the volumetric controlled dispensing of water with an
increment of 0.1 L and a tap volume from 0.1 to 99 L. The system
prevents overflow of containers and allows to dispense water
without supervising.
bench integrated To save valuable benchtop space the Astacus² can be ordered See
as BI configuration. The system will be installed underneath the configurations
work bench and only the display and dispenser are mounted on
the wall or table.
IQ/OQ Validation of IQ/OQ documents for Astacus² & Aquinity² 915-0042
documents
6
Water Purification Systems
The system Aquinity² P10 is designed for the production of ultra pure water
(0.055 μS/cm) out of tap water. The Aquinity² P10 system is equipped with
a reverse osmosis (RO) to produce deionised water into the integrated
10 liter storage tank with a production rate of 8 L/h. In the next step the ultra
pure water is produced with a combination of optimized mixed bed cartridge
and can be tapped with a flexible dispenser. If water is not used, automatic
recirculation within the Aquinity² system ensures a permanent high quality
of ultra pure water. All components of the Aquinity² are assembled in an
especially designed housing. The system can be easily opened by removing
the side panel to access the ultra pure module and UV lamp
(185 nm/ 254 nm).
7
Water Purification Systems
Technical Specifications
ultra pure water quality 0.055 μS/cm; Type I
total organic carbon (TOC) < 10 ppb Reagent | < 3 ppb Analytical
dimensions, weight, power 504 x 340 x 535 mm, 16 - 20 kg, 110 - 230 V
*not possible to tap pure water ** with microbiological final filter
pH 3 to 9
temperature 5 to 25 °C
Configurations
Model UV reactor Cat. No.
Reagent - 114-0070
Analytical + 114-0071
8
Water Purification Systems
Options
TOC monitoring The TOC monitoring during production and intermittent 830-0584
(TI version) measurements during non-use periods allows to check the
organic content in water continously between 1 and 999 ppb.
volumetric upgrading of water system to volumetric dispense function 180-0093
dispensing allows the volumetric controlled dispensing of water with an
increment of 0.1 L and a tap volume from 0.1 to 99 L. The system
prevents overflow of containers and allows to dispense water
without supervising.
bench To save valuable benchtop space the Aquinity² can be ordered Upon request
integrated as BI configuration. The system will be installed underneath the
work bench and only the display and dispenser are mounted on
the wall or table.
IQ/OQ Validation of IQ/OQ documents for Astacus² & Aquinity² 915-0042
documents
9
Water Purification Systems
10
Water Purification Systems
Technical Specifications
Pure water + ultra pure water < 2 µS/cm; Type II + 0.055 μS/cm; Type I
total organic carbon (TOC) < 10 ppb Reagent | < 5 ppb Life Science | < 3 ppb Analytical
dimensions, weight, power 504 x 680 x 535 mm, 16 - 20 kg, 110 - 230 V
*with Life Science model
temperature 5 to 25 °C
Configurations
Model UV UF module TOC Cat. No. Cat. No. Aquinity² 20
reactor monitoring
(10 L/h) (35 L) (70 L) (20 L/h)
11
Water Purification Systems
Options
TOC monitoring The TOC monitoring during production and intermittent See
(TI version) measurements during non-use periods allows to check the configurations
organic content in water continously between 1 and 999 ppb.
volumetric upgrading of water system to volumetric dispense function 180-0093
dispensing allows the volumetric controlled dispensing of water with an
increment of 0.1 L and a tap volume from 0.1 to 99 L. The system
prevents overflow of containers and allows to dispense water
without supervising.
bench To save valuable benchtop space the Aquinity² can be ordered Upon request
integrated as BI configuration. The system will be installed underneath the
work bench and only the display and dispenser are mounted on
the wall or bench.
IQ/OQ Validation of IQ/OQ documents for Astacus² & Aquinity² 915-0042
documents
12
Water Purification Systems
13
Water Purification Systems
Technical Specifications
Pure water + ultra pure water < 0.2 µS/cm; Type II + 0.055 μS/cm; Type I
total organic carbon (TOC) < 10 ppb Reagent | < 5 ppb Life Science | < 3 ppb Analytical
dimensions, weight, power 504 x 680 x 535 mm, 16 - 20 kg, 110 - 230 V
*with Life Science model ** with microbiological final filter
Iron | manganese | sulfate < 0.01 mg/mL | < 0.01 mg/mL | < 2 mg/mL
pH 3 to 9
temperature 5 to 25 °C
14
Water Purification Systems
Configurations
Model UV UF module TOC Cat. No. Cat. No. Aquinity² 20
reactor monitoring
(10 L/h) (35 L) (70 L) (20 L/h)
Options
TOC monitoring The TOC monitoring during production and intermittent See
(TI version) measurements during non-use periods allows to check the configurations
organic content in water continously between 1 and 999 ppb.
volumetric upgrading of water system to volumetric dispense function 180-0093
dispensing allows the volumetric controlled dispensing of water with an
increment of 0.1 L and a tap volume from 0.1 to 99 L. The system
prevents overflow of containers and allows to dispense water
without supervising.
bench To save valuable benchtop space the Aquinity² can be ordered Upon request
integrated as BI configuration. The system will be installed underneath the
work bench and only the display and dispenser are mounted on
the wall.
IQ/OQ Validation of IQ/OQ documents for Astacus² & Aquinity² 915-0042
documents
15
Water Purification Systems
16
Water Purification Systems
The series of AquaRO² and EDI² are designed for the production of pure water (10 μS/cm to 0.2 μS/cm)
out of tap water.
The series of AquaRO², AquaRO²DI and EDI² are based on a reverse osmosis (RO) unit to produce
deionised water. The EDI² series further processes the osmosis water by using an EDI cell to get type II
water. The advantages of both series is the flexibility in terms of configuration. A production rate of 8 to
40 L/h in three different degrees of pure water (10 μS/cm to 0.2 μS/cm) is available. Optionally the
systems can be equipped with a dispenser. The customer can optionally choose a 35 L or 70 L tank or
individual. All components of the AquaRO² and EDI² series are assembled in an especially designed
housing. The systems can be easily opened by removing the side panel to access the spare parts.
17
Water Purification Systems
18
Water Purification Systems
Technical Specifications
Model AquaRO² AquaRO² DI AquaRO² 8 P10 EDI²
AquaRO² 8 P10 DI
Pure water quality < 10 µS/cm < 2 µS/cm; Type II < 10 µS/cm < 0.2 µS/cm; Type II
< 2 µS/cm
Resistivity > 0.1 MΩ·cm 0.5 MΩ·cm > 0.1 MΩ·cm 5 MΩ·cm
> 0.5 MΩ·cm
total organic carbon < 50 ppb < 40 ppb < 40 ppb < 20 ppb
(TOC)
type of feed water Potable water /Tap Potable water /Tap water
water
pH 3 to 9 3 to 9
temperature 5 to 25 °C 5 to 25 °C
19
Water Purification Systems
Configurations
Model Cat. No. Model Cat. No. Model Cat. No.
Options
Softener Unit Compact system in cabinet including control box for the 280-0014
pretreatment.
Upgrade with Upgrade of system with fixed and flexible dispenser 180-0088
Dispenser
20
Total organic carbon analyzer
2.1 miniTOC
Figure 11: The scheme shows the principle of measuring the TOC value via conductivity with miniTOC.
21
Total organic carbon analyzer
Technical Specifications
Total organic Carbon
Sample
max. input conductivity < 2 μS/cm (upgradable to < 10 μS/cm and 30 µS/cm)
Measurement
22
Total organic carbon analyzer
Operating Conditions
Physical Specifications
Communication
digital output 1 x Relay Signal (Alarms & TOC Limit) + USB for Data export
Compliance
23
Total organic carbon analyzer
Options
configuration The miniTOC can be ordered as configuration with 4 inputs. 275-0016
miniTOC pro This and an additional software called interval mode upgrade
option allows the user to measure up to 3 loops sequentially
and configure the duration of the interval.
analog output 0-20 mA signal of TOC and conductivity, according to Namur 275-0020
NE43 it is adjustable 0 - 4 mA to differentiate between idle
status and signal error
analog output, just needed if interval mode is requested 275-0030
interval mode
interval mode Allows in combination with the configuration miniTOC pro the 275-0029
user to measure up to 3 loops sequentially and configure the
duration of the interval.
check of inlet control of inlet pressure, miniTOC, initiates alarm in case of inlet 275-0023
pressure flow is zero
21 CFR part 11 Software with 21 CFR part 11 conformity for pharma 275-0062
software applications
IP 54 The housing protects the miniTOC from dust deposits a water 275-0058 +
jets.
275-0059
autosampler By using the offline mode of the miniTOC the system is also 275-0055
upgradable with an autosampler with 15 positions for 100 mL
vials (miniTOC pro 275-0016 and offline mode 275-0051 are
required)
24
Total organic carbon analyzer
25
Total organic carbon analyzer
In addition to the spare parts listed above, the customer can also purchase the contents of our service kits for
miniTOC.
T connector 825-0269 1 pc
26
Total organic carbon analyzer
2.2 uniTOC
Figure 12: The scheme shows the principle of uniTOC with the two different pathways for TIC and TOC and the
principle of measuring the TOC value.
27
Total organic carbon analyzer
Technical Specifications
method & detection UV oxidation & NDIR (enhanced oxidation; configurable with reagent)
measurement range 2 to 5000 ppb (low range), 15 ppb to 20000 ppb (high range)
related norms USP <643>, EP 2.2.44, DIN EN 1484, DIN 32645, 21 CFR part11, IP 45
dimensions, weight, power 400 x 300 x 600 mm, 24 kg, 110 - 230 V, 50 Hz, 70 to 105 Watt
Medium Requirements
type of sample medium from water to ultra pure water
sample temperature 10 to 50 °C
28
Total organic carbon analyzer
Options
air filtration unit to use compressed air instead of oxygen or nitrogen 275-0012
Software unidata software for additional PC enables the user to evaluate 275-0018
the results at an external computer
pressure If the medium pressure is higher than 1 bar a pressure reducer 921-0362
regulator is required.
29
Total organic carbon analyzer
In addition to the spare parts listed above, the customer can also purchase the contents of our service kits for uniTOC.
30
Total organic carbon analyzer
31
Amino Acid Analyzer
3.1 ARACUS
ARACUS works according to gold standard of post column derivatization with ninhydrin, with detection at
440 nm and 570 nm using maintenance free LED photometers. A separation of up to 44 amino acids in
about one hour is possible, but also of a few amino acids within a few minutes. ARACUS is used in clinical
laboratory (e.g. newborn screening), in quality control for Food (own patent 10 2016 010 887), beverages
and feedstuff and in research.
Figure 13: The scheme shows the principle of ARACUS with the pathways for eluents, sample and reagent solution.
Following the separation of the amino acids inside the column, the mixture of sample and reagent solution flows
through a reactor for the chemical reaction. Finally the flow passes the LED photometers (570 nm + 440 nm), where
the amino acids will be detected indirectly by formed dye.
32
Amino Acid Analyzer
Technical Specifications
method post column derivatization with ninhydrin
autosampler 2 racks, each of them with space for 48 vials (1.5 mL), sample
cooling dosage in 3 different injection modes:
full loop (100 μL), partial loop (5-50 µL), microliter pickup (1-35 μL)
column stainless steel, cation exchange resin
reproducibility of retention time < 0.3 % RSD
reproducibility of peak area ~ 1.0 % RSD
column oven 20 – 80 °C, accuracy 0.1 %
ready to use kits kits including eluents, reagent and additional dilution buffer,
ammonia adsorber and separation columns for 500 runs
(customized kits upon request)
control software & data Clarity (21 CFR Part 11 compliant) or AminoPeak
acquisition
dimensions, weight, power 1080 x 370 x 690 mm*, 60 kg, 110 - 230 V, 50/60 Hz
*800 mm with opened main unit
33
Amino Acid Analyzer
accessory kit Tubes, fittings, syringe for pump, sample vials 1.5 mL and 600-0051
caps (100 pcs). The included components are listed under the
section spare parts.
computer Tested to control analyzer 600-0032
Options
ARACUS 2 pump system allows to operate in a single fluidic line for 600-0066
advanced buffer and reagent (required for OPA post column derivatization
method)
Upgrade Elubox Active control of fluid volume by weight cell of each bottle. (only 600-0038
available with software AminoPeak)
inert gas it supplies the main unit and eluent box with a protective gas 600-0056
atmosphere by reducing the presence of atmospheric oxygen
to enhance the signal to noise ratio
Software 21 Manual and automatic peak integration with integrated IQ/OQ 600-0061
CFR part 11 procedure for software (only available with software Clarity)
34
Amino Acid Analyzer
Figure 14: performed with the column kit Cat. No. 650-0157 and supplement kit Cat. No. 650-0162.
35
Amino Acid Analyzer
Figure 15: performed with the column kit Cat. No. 650-0126 and supplement kit Cat. No. 650-0153.
Figure 16: performed with the column kit Cat. No. 650-0126 and supplement kit Cat. No. 650-0211.
36
Amino Acid Analyzer
Figure 17: performed with the column kit Cat. No. 650-0178 and supplement kit Cat. No. 650-0131.
37
Amino Acid Analyzer
Example I:
Example II:
Figure 19: Both chromatograms were performed with the column kit Cat. No. 650-0157 and supplement kit
Cat. No. 650-0162.
38
Amino Acid Analyzer
Figure 20: performed with the column kit Cat. No. 650-0126 and supplement kit Cat. No. 650-0153.
Figure 21: performed with the column kit Cat. No. 650-0187 and supplement kit Cat. No. 650-0185.
Figure 22: performed with the column kit 650-0190 and supplement kit Cat. No. 650-0196.
39
Amino Acid Analyzer
Figure 23: performed with the column kit Cat. No. 650-0165 and supplement kit Cat. No. 650-0167.
Figure 24: performed with the column kit Cat. No. 650-0165 and supplement kit Cat. No. 650-0197.
Figure 25: performed with the column kit Cat. No. 650-0140 and supplement kit Cat. No. 650-0147
40
Amino Acid Analyzer
Figure 26: performed with the column kit Cat. No. 650-0126 and supplement kit Cat. No. 650-0153.
Figure 27: performed with the column kit 650-0190 and supplement kit Cat. No. 650-0196.
41
Amino Acid Analyzer
42
Amino Acid Analyzer
In addition the customer can also purchase our spare parts for ARACUS. Usually it is not needed because our system
is low maintanance and all components have a long service life.
Fitting litetouch short male nut PEEK 1/16” ¼-28 – grey 860-1046*
43
Amino Acid Analyzer
Fitting litetouch short male nut PEEK 1/16” ¼-28 – red 860-1048*
Fitting litetouch short male nut PEEK 1/16” ¼-28 - blue 860-1043*
44
Amino Acid Analyzer
45
Amino Acid Analyzer
46
Amino Acid Analyzer
47
Amino Acid Analyzer
Our Service
Sample preparation and hydrolysis 690-0002
Includes hydrolysis of peptide/protein, deproteination and desalting of
sample according to standardized procedure
Sample preparation of Physiological samples 690-0006
includes hydrolysis, deproteination and desalting of samples following our
standard procedure.
Analytical Run - Single Run 690-0003
measurement of identity and quantity of amino acid content of sample, one
analytical run with internal and/or external standard
Analytical Runs - Double Run 690-0004
Includes measurement of identity and quantity of amino acid content of
sample, two analytical runs with internal and/or external standard
Analytical Runs - Triple Run 690-0005
Includes measurement of identity and quantity of amino acid content of
sample, three analytical runs with internal and/or external standard
Final Report with discussion of results, Single run* 690-0007
Includes qualitative and quantitative evaluation of samples, complete
report with discussion and conclusions of results
Final Report with discussion of results, Double run* 690-0008
Includes qualitative and quantitative evaluation of samples, complete
report with discussion and conclusions of results
Final Report with discussion of results, Triple run* 690-0009
Includes qualitative and quantitative evaluation of samples, complete
report with discussion and conclusions of results
*Pricing depends on the evaluation of 10, 20 or 42 amino acid.
Each sample must be provided with a precise description of the sample by the customer.
48
Ion Chromatograph
4 Ion Chromatograph
4.1 IONUS
IONUS can be used for the analysis of anions and cations in research, development and everyday
routine for aqueous solutions as well as for waters within the scope of environmentally relevant
investigations. This chromatograph separates anions (for anions optionally with suppressor
technology) according to EPA 300.0 and cations. The advantage of IONUS is the compatibility with the
common eluents of anion and cation exchange chromatography. By suitable post column
derivatization, transition metals (VIS detection) as well as bromate (EPA 317.0 or EPA 326) can be
detected. If requested, the IONUS can be equipped with an UV/VIS detector for indirect UV detection.
control software & data Clarity (21 CFR Part 11 compliant) or IonPeak
acquisition
dimensions, weight, power 1000 x 370 x 690 mm*, 60 kg, 110 - 230 V
*800 mm with opened main unit
49
Ion Chromatograph
accessory kit Tubes, fittings, syringe for pump, sample vials 1.5 mL and 860-1540
caps (100 pcs). The included components are listed under the
section consumables & spare parts.
computer Tested to control analyzer 600-0032
Column(s) depends on customer´s applications. The IONUS can analyse see. 5.1.1
anions or cations in subsequent mode.
installation Installation and customer/distributor training at customer site 915-0022
training or on site of membraPure of an IONUS. Travel and
accomodation to be paid separately by customer.
Options
Bromate Bromate Analyzer is a dedicated system with post column 600-0059
Analyzer derivatization for determination of Bromate according to EPA
317 or 326.
Software 21 Manual and automatic peak integration with integrated IQ/OQ 600-0061
CFR part 11 procedure for software (only available with software Clarity)
UV/VIS detector Detector with Deuterium and Tungsten lamp (190 – 800 nm), 600-0070
analytical measuring cell: volumina 12 µL, max pressure 100 bar
50
Ion Chromatograph
Columns
Dimensions Determination of Suppressor Remarks Cat. No.
PRP-X100 (Standard), SS Anions yes / no EPA 300 part A 650-0105
50 mm x 4.1 mm ID, 5 µm
PRP-X110S, SS Anions + yes EPA 300 part B 650-0195
250 mm x 4.1 mm ID, 7 µm Oxohalides
PRP-X100, PEEK Bromate no EPA 317 650-0105
100 mm x 4.6 mm ID, 5 µm
PRP-X100, PEEK Bromate no EPA 326 650-0132
150 mm x 2.1 mm ID, 5 µm
PRP-X800 (Standard), PEEK Standard Cations no - 650-0109
250 mm x 4.6 mm ID, 7 µm
Nucleosil 100, SS Transition metals no PCD with VIS 650-0099
150 mm x 4.6 mm ID, 5 µm
Eurokat, SS Organic Acids no Indirect UV 650-0180
300 mm x 8 mm ID
Further columns upon request!
51
Ion Chromatograph
Figure 28: both chromatograms were performed with the column Cat. No. 650-0105 with 3.2 mM sodium
carbonate, 1.0 mM sodium hydrogen carbonate and 0.1 mM sodium thiocyanate as eluent with suppressor
technique.
52
Ion Chromatograph
Figure 29: chromatogram was performed with the column Cat. No. 650-0195 with 3.2 mM sodium carbonate,
1.0 mM sodium hydrogen carbonate and 0.1 mM sodium thiocyanate as eluent with suppressor technique.
53
Ion Chromatograph
Figure 30: both chromatograms were performed with the column Cat. No. 650-0109 with 5.0 mM nitric acid as
eluent.
54
Ion Chromatograph
Figure 31: both chromatograms were performed with the column Cat. No. 650-0180 with 10.0 mM sulfuric acid as
eluent with indirect UV method.
55
Ion Chromatograph
Figure 32: performed with the column Cat. No. 650-0106 with 200 mM methane sulfonic acid as eluent and
0.27 M potassium iodide and 50 µM ammonia heptamolybdate as reagent according to method EPA 326.0
(UV detection 355 nm) with a concentration range of 100 – 1 ppb for bromate.
In addition the customer can also purchase our spare parts for IONUS. Usually it is not needed because our system
is low maintanance and all components have a long service life.
56
Ion Chromatograph
syringe with luer adapter 5 mL and needle for pump backflush 860-1869* + 1872*
Fitting litetouch short male nut PEEK 1/16” ¼-28 – grey 860-1046*
Fitting litetouch short male nut PEEK 1/16” ¼-28 – red 860-1048*
Fitting litetouch short male nut PEEK 1/16” ¼-28 - blue 860-1043*
57
5 Appendix
5.1 Content of standard amino acids, physiological standard (cat. No. 650-0035)
22 Methionine MET
5.2 Content of standard amino acids, hydrolysate standard (cat. No. 650-0036)
2 Cadaverine
3 Dopamine
4 Histamine
5 Putrescine
6 Spermidine
7 Spermin
8 Tyramine
2 Chloride 2 Sodium
3 Nitrite 3 Ammonium
4 Bromide 4 Potassium
5 Nitrate 5 Calcium
6 Phosphate 6 Magnesium
7 Sulfate
Notes:
membraPure GmbH
Wolfgang-Küntscher-Str. 14
D - 16761 Hennigsdorf
Germany
Tel: +49-3302/201-20 0
Technical Service: +49-3302/201-20 20
Fax: +49-3302/201-20 21
info@membrapure.de
www.membrapure.de