In any constant potential charging system the battery charge current will vary according to the battery demand as
determined by its state of charge/discharge. If the battery has been deeply discharged for a prolonged period
following a mains failure the resultant charge current upon restoration of the mains would be proportionally high in the
first instance and would reduce thereafter as the battery recovers and its terminals voltage rises.
To safeguard the charger from such high current demand and to optimise the rating of the charger, current limiting
circuitry is included within the system.
The charger characteristics changes from a current limited, constant current type at low battery voltage to a variable
current, constant potential type as the battery voltage recovers to its fully charged state. When fully charged the
battery is maintained constantly at its float voltage level while the charge current is reduced to a level sufficient to
offset system losses and maintain the battery in a fully charged condition.
In order to ensure that the correct charger system is selected to meet your requirements the minimum information
needed is as follows:
i.
ii.
iii.
iv.
v.
vi.
vii.
viii.
ix.
System application
System operating voltage, ie: number of cells in series.
The standing and/or intermittent load on the system.
Standby duration, ie: the number of hours the system is to support the load in iii. above following a mains failure.
The loads voltage limits, ie: maximum and minimum.
Battery type (NB: the ampere hour capacity may be specified if known).
The maximum time required for battery recharge in order to repeat the load duty.
The anticipated frequency of discharge imposed on the battery, ie: the charge/discharge cycling requirements.
The ambient operating/design temperature, eg: maximum, minimum, average maximum, average minimum, etc.
MODE OF OPERATION
Floating System
Provides a continuous DC supply at the load terminals at all times. By suitably sizing the charger the system can support a
directly connected load continuously when the mains supply is healthy providing a true NO-BREAK supply. With this mode of
operation a unique system is available that independently controls the battery charge current and the load current. This ensures
that the battery receives the correct charge at all times and therefore helps to maintain its operating life (refer to Manufacturer
for more details).
BATTERY SELECTION
There are three principle considerations when it comes to selecting a battery type, these being the INITIAL CAPITAL COST, the
batterys DESIGN LIFE and the MAINTENANCE REQUIREMENTS. It is necessary to make decisions such as whether a lower
initial cost is more important that the total cost over the anticipated life of the installation (including any maintenance
requirements). The above can best be summarised for each of the size battery types being offered by the following table:
Battery
Type
Cost Effective
Sealed Lead
Acid
Sealed Lead
Acid to BS6290
Tubular Plate
Lead Acid
Plante
Nickel
Cadmium
MainenanceFree Nickel
Cadmium
Design Life
!!!!
!!!!
!!!!!!
!!!!!!!!
!!!!!!!!!!
!!!!!!!!!!
Maintenance
Requirement
STANDARD RANGE
1500 SERIES
SINGLE PHASE
VOLTS/AMPS
CUBICLE
SIZE/APPROX.
WEIGHT
INPUT/
KVA
3500 SERIES
THREE PHASE
VOLTS/AMPS
1500 SERIES
SINGLE PHASE
VOLTS/AMPS
CUBICLE
SIZE/APPROX.
WEIGHT
INPUT/
KVA
3500 SERIES
THREE PHASE
VOLTS/AMPS
12/3
12/6
12/10
12/12
12/16
12/20
12/30
12/40
12/50
12/60
12/75
12/100
12/125
12/150
12/200
2/10kg
2/15kg
2/18kg
2/22kg
4/28kg
4/34kg
4/46kg
4/52kg
5/60kg
5/70kg
5/80kg
5/92kg
6/110kg
6/120kg
6/146kg
.06
.12
.22
.26
.35
.44
.66
.88
1.1
1.3
1.6
2.2
2.7
3.3
4.4
3512/100A
3512/125A
3512/150A
3512/200A
220/20A
220/25
220/30
220/40
220/50
220/60
220/75
220/100
6/200kg
6X/240kg
6X/250kg
6X/265kg
8/390kg
8/420kg
8/500kg
9/560kg
7.3
9.2
11
14
18.4
22
27
37
35220/20A
35220/25A
35220/30A
35220/40A
35220/50A
35220/60A
35220/75A
35220/100A
24/3
24/6
24/10
24/12
24/16
24/20
24/25
24/30
24/40
24/50
24/60
24/75
24/100
24/125
24/150
24/200
24/225
24/250
24/275
24/300
24/400
30/3
30/6
30/10
30/12
30/16
30/20
30/25
30/30
30/40
30/50
2/20kg
2/26kg
2/34kg
2/38kg
4/46kg
4/50kg
4/60kg
4/65kg
5/70kg
5/78kg
5/100kg
6/120kg
6/140kg
6/170kg
6X/190kg
6X/210kg
6X/230kg
6X/260kg
6X/280kg
8/310kg
8/340kg
2/22kg
2/28kg
4/38kg
4/42kg
4/48kg
4/50kg
4/56kg
4/60kg
5/68kg
5/80kg
.12
.24
.43
.51
.68
.86
1.1
1.3
1.7
2.2
2.6
3.2
4.4
5.3
6.4
.6
9.6
10
11
13
17
.14
.28
.49
.56
.78
.98
1.2
1.4
1.9
2.4
3524/50A
3524/60A
3524/75A
3524/100A
3524/125A
3524/150A
3224/200A
3524/225A
3524/250A
3524/275A
3524/300A
3524/400A
3530/40A
3530/50A
50/3
50/6
50/10
50/12
50/16
50/20
50/25
50/30
50/40
50/50
50/60
50/75
50/100
50/125
50/150
50/200
50/250
2/25kg
2/34kg
4/40kg
4/42kg
4/48kg
5/60kg
5/64kg
5/78kg
5/100kg
5/130kg
6/160kg
6/170kg
6/200kg
6X/230kg
6X/280kg
6X/330kg
8/360kg
.26
.52
.86
1.0
1.3
1.7
2.1
2.6
3.4
4.2
5.2
6.4
8.2
10
13
17
21
3550/25A
3550/30A
3550/40A
3550/50A
3550/60A
3550/75A
3550/100A
3550/125A
3550/150A
3550/200A
3550/250A
110/3
110/6
110/10
110/12
110/16
110/20
110/25
110/30
110/40
110/50
110/75
110/100
110/125
110/150
4/32kg
4/42kg
5/50kg
5/55kg
5/75kg
5/100kg
5/120kg
6/150kg
6/200kg
6/220kg
6X/260kg
8/350kg
8/450kg
8/500kg
.5
1.0
1.7
2.0
2.7
3.4
4.3
5.1
6.8
8.6
13
17
22
26
35110/12A
35110/16A
35110/20A
35110/25A
35110/30A
35110/40A
35110/50A
35110/75A
35110/100A
35110/125A
35110/150A
220/3A
220/6A
220/10A
220/16
5/42kg
5/64kg
6/109kg
6/150kg
1.1
2.2
3.7
5.9
35220/6A
35220/10A
35220/15A
NOMENCLATURE
EXAMPLE
24 VOLT Charger/Battery system with single phase AC
mains input. Rated at 125A. The battery is to
comprise 10 year life Sealed Lead Acid cells to BS6290
part 4.
@100AH capacity.
PCV1#
024
0125
SL
100
OPTIONS
SERIES/MODEL
PCV1# = Single Phase Charger in Cubicle
PCV3# = Three Phase Charger in Cubicle
PCM1# = Single Phase Charger on Chassis
PCM3# = Three Phase Charger on Chassis
SYSTEM VOLTAGE
12v, 24v, 30v, 48/50v, 110v or 220v
CHARGER RATING
Charger Output Current in Amps
CELL TYPE
CL
- Cost Effective Sealed Lead Acid
SL
- Sealed Lead Acid to BS6290 part 4
TL
- Tubular Plate Lead Acid Monobloc
PL
- Vented Plante Lead Acid
VN
- Vented Nickel Cadmium
SN
- Maintenance-Free Nickel Cadmium
BATTERY CAPACITY
Stated in Ampere Hours for given rates of discharge
(NB: The quoted rates of discharge vary for each cell
type, eg: Vented Nickel Cadmium cells normally have
their capacity stated at the 5 hour rate of discharge
whereas Lead Acid cells normally have theirs stated at
the 10 hour rate of discharge).
OPTIONS
CCITT DD
FFA
LEA
BSI
EFA
LVD
*SB
*DB
*SF
*DF
RAU
AAR
SP
-
Input Voltage
220/240v 6%, single phase (Series
1500) or 380/415v 6%, three phase
(Series 3500) (other voltages to special
order).
Input Frequency
50 or 60HZ 3%
Output Voltage
Charger
Max. Float Voltage Range
Voltage
12v
13
to
17v
24v
25
to
34v
30v
32
to
42v
48/50v
52
to
75v
110v
115
to
156v
220v
225
to
314v
Charger
Solid state thyristor controlled constant
voltage type with current limit and manual
boost. Inherently protected against low
battery voltage, reversed battery
connection and short circuit conditions.
Standards Approvals
BS EN 50081-1
1992
BS EN 50082-1
1992
BS EN 50081-2
1992
BS EN 50082-2
1992
BS EN 60950
BS EN 55014
1995-1
1993
Cooling
Air natural convection
Temperature Range
OIperating: -10C to 35C
Storage/transportation: -20C to 65C
(NB: Higher operational temperatures are
possible by suitably re-rating the charger.
Refer to manufacturer for details).
Instrumentation
Single Digital meter to indicate battery
voltage and battery current (charge and
discharge current) selectable via
pushbutton switch.
Indicators & Alarms
Functions
Mains on
Float
Boost (if applicable)
Charger healthy
Mains supply fail
Charger fail
Low volts
High volts
Reset-Silence-Test
System fault
Mini Alarm Module
Float
Boost
Charger healthy
Reset-Silence-Test
Charger fail
Low volts
High volts
Optional Extras
Battery Impedance
Earth Fault +/Circuit Breaker Fault
Battery Fault
Earth Fault
LED Colour
Amber
Green
Flashing Yellow
Green
Red
Red
Red
Red
Test Lamp Pushbutton
Flashing Red
Green
Yellow Flashing
Pushbutton
Green
Test Lamp Pushbutton
Red
Red
Red
Red
Red
Red
Red
Red
HEIGHT (mm)
500
660
500
1250
1700
1700
1700
1700
1700
WIDTH (mm)
460
600
750
750
750
600
750
1000
750
DEPTH (mm)
265
440
455
455
455
630
820
820
650
CHASSIS SIZE
350 X 300 X 200
420 X 520 X 250*
420 X 520 X 250*
420 X 520 X 250*
420 X 520 X 250*
420 X 520 X 250*
420 X 520 X 250*
*Note: for larger units wound components supplied loose for accommodation elsewhere
CONTACT
STANDARD
SPECIFICATION
RECOGNISED AS LEADERS IN
STANDBY AND POWER SOLUTIONS
This publication is issued for guidance and to provide outline information only and is not deemed to form part of any offer or contract. Our policy is
one of continued improvement and we reserve the right to vary details without prior notice.