You are on page 1of 1

HINDUSTAN PETROLEUM CORPORATION LIMITED

TENDER FOR COMPOSITE WORK FOR PUMP MP2 INSTALLATION AT KHOPOLI BOOSTER STATION
UNDER CAPACITY AUGMENTATION PROJECT
MUMBAI-PUNE-SOLAPUR PIPELEINE

d) Compressive strength
e) Consistency

Sand

For
concreting

4.

Coarse
aggregate

For
concreting

6.

Reinforcem
ent steel

Cement
Concrete

12269

and Lab test for


each batch
brought to site.

IS 2386

IS 383

Every 40 Cum
or part thereof.

a) Percentage of soft /
deleterious material
b) Particle Size distribution
c) Organic impurities
d) Sp. Gravity
e) Bulk density
f) Aggregate crushing
strength
g) Aggregate impact value
h) Alkali Reactivity
i) Flakiness index

I.S. 2386

I.S. 383

a)
b)
c)
d)
e)
f)

I.S. 1608

a)
b)
c)
d)
e)
f)

Particle Size distribution


Sp. Gravity
Deleterious substance
Organic impurities
Water absorption
Fineness modulus

Physical properties
Chemical test
Bend & rebend test
Elongation test
0.2% Proof stress
Tensile strength

One test for


each source

Every 40 cum or
part thereof

I.S. 1786

Each lot from


each source for
each dia.
Min. Qty 10
MT. Test to be
repeated for
every 10 MT or
part there of.

a) Slump test

I.S. 1199

I.S. 456

15 Cum or part
thereof

a) Slump test

I.S. 1199

I.S. 456

Every 5 cum

(For PCC)
7

Cement
concrete

b) Cube test ( three cubes


for 7 days strength and 3

Page 94 of 185

Qty.

No. of

Seal & Signature of Tenderer

You might also like