You are on page 1of 2

August 13, 2015

RotoSize: Version 4.40 29 JAN 2002

Job Reference Information :


Job Number
Job Reference
End User
Packager
Driver/Model

:
:
:
:
:

Sizing Input Information :


Ambient Temp :
Location Elevation :
Gas Type Selection :
Relative Humidity :
Specific Gravity :
k-value Cp/Cv :
Suction gage pressure :
Inlet Gas Temp :
Discharge gage pressure :
Design Flow Rate :

100 F
0
Air
100
1.00
1.4
0 PSI
100 F
120 PSI
0.27 MMSCFD

Conditions used in sizing/rating the unit:


Suction PSIA
Discharge PSIA
Location Atmospheric Pressure
Moisture Factor Multiplier

14.70
134.70
14.70
1.070

Selected Frame :
Frame Selection :
Design Rpm :
Min Rpm :
Max Rpm :
Max Suction Pressure, PSIG
Max Power allowed, BHP
Driver type selection :
Unit is equipped with a Turn

SSHG99B (5.17 VI)


1800.0
863
3777
50
90
Electric (60 Hz)
Valve, set at 88 %.

Rating/Sizing Results: ( Note: This is a Flange-to-Flange Rating


Discharge Temp, Degrees F
Oil Inlet Temp, Degrees F
Temperature RISE, Degrees Fahrenheit
REQUIRED Flow in INLET Cu Ft per Min.
RATED Flow in ICFM at op. RPM
Volumetric Efficiency at op. RPM
Adiabatic Efficiency at op. RPM
REQUIRED Flow in Millions of SCF/Day

198
180
18
216.0
216.0
79.45
72.61
0.270

RATED Flow in Millions of SCF/Day


RATED Flow in SCFM
RATED FLOW, lb/min

0.270 MMSCFD
187.5
14.94

RATED BHP at operating point


OIL FLOW CALCULATED, Gal/Min
OIL Cooler Heat Load, MMBTU/Hr
Internal Vol. Ratio ("VI")
Internal Comp. Ratio
Job Compression Ratio

52.6 BHP
31.4
0.148
5.17
9.97
9.16

NOTE! This unit has a frame-mounted oil pump


but the oil flow around the pump in the BYPASS is GREATER than
the pump rate. The BYPASS flow is the oil flow rate used above.
No warnings detected due to compressor operating conditions.
The "Use Compressibility" option is:
ON, Zs = 1.000, and Zd = 0.999.

August 13, 2015


Oil Separator Design Report:
Standard Separator Size : 600_T
Separator Sizing Basis Information :
Suction Pressure
:
0.0
Discharge Pressure :
120.0
RPM
:
1800.0
Oil GPM = 31.37 at 50.833 #/FT3
MMSCF/D =
0.27 at 0.5531 #/FT3
Horizontal Vessel Min. Dimensions:
I.D.(Min.) = 20.000 and O.A. Length =
Current Oil Selection : AEON-9000-SP

60.00 IN.