Overview
In general, WCDMA system is consisting of Core Network (CN), UMTS Terrestrial Radio
Access Network (UTRAN) and User Equipment (UE). UTRAN has two network elements:
Node B and RNC. Iub is defined as the interface between RNC and Node B. Fig 1
shows the position of RNC in WCDMA system.
Figure 1
Radio Resource Management such as power control, cell resource allocation etc.
ZTE RNC product, named ZXWR RNC (hereinafter refer to RNC), is based on 3GPP
FDD R8, being compatible with other network elements and UE based on
R99/R4/R5/R6/R7/R8. At the same time, ZXWR RNC provides series standard
interfaces including Iu, Iub, Iur etc, supporting to connect with other venders equipments
such as CN, RNC etc.
Highlight Features
The ZXWR products always aim at saving customers investment in 3G products by
offering a large capacity and linear expandable system once and for all. This facilitates
high density 3G services. The RNC adopts distributing design, separates control plane
from user plane, interface from application, supports ATM protocol stack, it also supports
all IP UTRAN. The RNC system has the following features:
2.1
2.2
2.3
High reliability
The RNC has high reliability and stability. The system is based on redundancy design.
So there is no single point of failure. The system supports online software download and
there is no need to reboot after version upgrade.
2.4
2.5
System Architecture
3.1
Figure 2
Figure 3
3.2
Hardware Architecture
RNC hardware logical units are shown as:
Figure 4
3.2.1
RPU
The RPU (RNC Processing Unit) processes control plane signaling and user plane
information, including RCB (RNC control board) and RUB (RNC user board) boards.
3.2.1.1
RCB
RCB accomplishes the control protocol processing of RNC, such as RANAP, NBAP,
RNSAP, RRC, SABP etc.
RCB board is RNC Control Plane Processing Board.
Ability: 420cell; 440k BHCA
Considering 1+1 backup
34 boards for maximum configuration
3.2.1.2
RUB
RUB (RNC User Plane Processing Board) is a user plane processing board of RNC,
dealing with the user plane protocols. RUB deals with the radio user plane protocols,
including CS service FP/MAC/RLC/IuUP/RTP/RTCP protocol stack and PS service
FP/MAC/RLC/PDCP/IuUP, GTP-U protocols.
Each RUB can process 2100Erl for CS domain, or process 265Mbps for PS domain;
RUB: N+1 Backup
28boards for maximum configuration
3.2.2
RAU
RAU (RNC Access Unit) provides the interface access function for Iu, Iub and Iur of RNC.
RAU is configured with the following boards:
3.2.2.1
DTA
DTA is used to provide ATM over E1/T1 interfaces
DTA provides 32*E1/T1 electrical interfaces and supports 30 IMA groups.
3.2.2.2
DTI
DTI is used to provide IP over E1/T1 interfaces
DTI supports 32*E1/T1 electrical interfaces, and supports 32 MLPPP groups.
3.2.2.3
SDTA2
SDTA2 is used to provide channelized STM-1 interfaces and IMA protocol processing.
SDTA2 provides 4 channelized STM-1 optical interfaces, and supports 168 IMA groups.
3.2.2.4
SDTI
SDTI is used to provide channelized STM-1 interfaces and MLPPP protocol processing.
SDTI provides 2 channelized STM-1 optical interfaces, and supports 64 MLPPP groups.
3.2.2.5
APBE
APBE is for the processing of ATM access over STM-1, and implements SAR
functionality of AAL2 and AAL5.
APBE provides 4 STM-1 optical interfaces.
3.2.2.6
POSI
POSI is for the processing of IP access over STM-1.
POSI provides 4 STM-1 optical interfaces.
3.2.2.7
GIPI4
GIPI board: Gigabit IP Interface board, 4th generation. GIPI4 provides FE/GE interfaces.
GIPI4 provides 2*GE optical interface/ electrical interfaces, or 4* FE electrical interfaces.
GIPI4 provides 2100Mbps throughput.
15boards for maximum configuration
3.2.3
RSU
The RSU (RNC Switch Unit) provides a large-capacity and non-blocking IP switching
unit for system control management, communication between service processing boards
and traffic connection among multiple RAUs.
It is constructed with:
3.2.3.1
PSN
PSN is the system switching board of RNC. It accomplishes kernel switching function of
RSU, implements the packet data switching of each GLI.
PSN supports up to 40Gbps switching capability.
3.2.3.2
GLI
GLI is the access switching board, which implements RPU/RAU access to RSU,
including the physical layer adaptation, IP package checklist, segment, forwarding and
traffic management etc, and it converges the data from RPU/RAU to PSN for switching.
3.2.3.3
UIMC
UIMC is a type of switching board of RNC, belonging to RSU. It accomplished switching
function among control plane processing boards, and clock distribution. Information
switching of UIMC boards in different shelves is implemented by THUB.
3.2.3.4
GUIM
GUIM is for the switching functionality of user plane processing boards. Information
switching of GUIM boards in different shelves is implemented by GLI and PSN.
3.2.3.5
THUB
THUB is for control plane data switching among different shelves. It supports 400Mbps
switching capability.
3.2.4
ROMU
The ROMU (RNC Operation and maintenance unit) is responsible for the general
processing and implementing O&M control (including O&M agent) of the entire system
as well as system clock supply and external synchronization.
It includes:
3.2.4.1
ROMB
ROMB as RNC O&M agent is used to monitor and manage all of the boards in the
system, and to implement the general processing of the system and route protocol
management.
3.2.4.2
CLKG
CLKG board is responsible for the clock supply and external synchronization. CLKG
board gets clock reference from BITS, GPS receiver or the circuit. After synchronization,
the signal is used at every interface shelf.
The default configuration of CLKG doesnt include GPS module. GPS module should be
added in CLKG if GPS clock or GPS location service is required.
8
3.2.4.3
SBCX
SBCX provides the operation and maintenance management agent functionality.
3.2.5
RPMU
RPMU (RNC Peripheral Monitor Unit) belongs to ROMU. It provides monitoring function
to peripheral equipments, and collects information of all boards, alarms while the system
has faults. It includes:
PWRD: Power Distributor
ALB: Alarm Box
3.2.5.1
PWRD
PWRD is not only responsible for -48V power provision for all shelves and fans in the
rack, but also for the collecting peripheral and circumstance information, including the
PWRD and fans status, temperature, smoke, water and infrared alarming.
PWRD reports the detected information to ROMB via RS485 interface.
3.2.5.2
ALB
Alarm box will obtain the alarm information from OMM, and send the different level
alarms according to different fault situations of the system in order to be managed and
intervened in time by the equipment management personnel.
ALB provides several alarm methods including SMS, LCD display, file transfer, voice
alarm etc.
Reliability Design
4.1
4.2
against the network security attacks. At the same time, the OMM subsystem supports
powerful user authentication functionality; the idea is that system will distribute relevant
operation permission according to user name and password.
RNC software system has powerful self-fault-tolerant capability, mainly reflected in:
Supporting key version and data backup, and performing rollback when version or
data loading failed
Supporting watch dog functionality, resetting the boards when software going
wrong and recording the failure information by black box function
Detecting the failure of ports, link and SW/HW, resetting/triggering backup unit to
guarantee system running normally
Technical Specifications
5.1
Technical Indices
Table 1
5.2
Item
Indices
Processing capability
76800 Erl
Data throughput
( Two-way data flow )
9.6Gbps
1960
5880
BHCA
7000K
Maximum Cabinet
Weight
Maximum Rack
Interface Indices
Table 2
10
Transmis
sion type
Standard
Interface
board
Port
Interface
Remark
E1/T1
ITU-T
G.703/G.704
DTA
DB68
Transmis
sion type
Channeliz
ed
STM1/OC-3
STM-1/OC3c
FE
ITU-T G.957
ITU-T I.432.1
ITU-T I.432.2
ITU-T G.957
ITU-T I.432.1
ITU-T I.432.2
IEEE 802.3
GE
5.3
Standard
IEEE 802.3
Interface
board
Port
Interface
Remark
DTI
DB68
SDTA2
LC/PC
SDTI
LC/PC
APBE
LC/PC
POSI
LC/PC
GIPI4
configured
with
FE
electrical
interface
RJ45
GIPI4
configured
with
GE
electrical
interface
RJ45
GIPI4
configured
with
GE
optical
interface
LC/PC
Clock Indices
Table 3
Item
Indices
Synchronization level
Level 2 class A
Clock
synchronous
interface
link
Each clock board supports 7 clock resource, including: 4 clock in equipment room
(2MHZ or 2Mbit), 2 line clock (8KHZ, acquired from Iu interface) and 1 * GPS clock. One
of the 7 clock resource will be specified as the working clock source via software
configuration, the rest clocks for standby.
11
When all the 7 clock sources are missing, clock board can work under free oscillation,
which is used by RNC.
No matter it is acquired from clock source or under free oscillation, RNC can provide its
own clock to NodeB.
5.4
Reliability Indices
In ZXWR RNC, the algorithm of system reliability is based on the GJB/Z299B Electronic
Equipment Reliability Estimation Manual and MIL-HDBK-217F Electronic Equipment
Reliability Estimation
Table 4
5.5
RNC Reliability
Item
Indices
MTBF
240000 hours
MTTR
0.5 hour
Availability
99.999792%
Downtime
1.09 minutes/year
5.6
Item
Standard
12
Item
Standard
350kg/m
Dimensions
5.7
Power Supply
Table 7
5.8
power supply
Item
Standard
Power input
-48V DC
3700W
Environment
Table 8
Item
Equipment
environment
Storage
environment
5.9
Indices
Temperature
Humidity
Noise
Requirements of
Equipment Site
350kg/m2
Atmospheric
pressure
70 kPa106 kPa
Transport
Environment
Transport environment:
2K4P/2B2/2C3/2S3/2M3
Sustainable transport time: 30 days
Intact package
Mechanical
Adaptability
Security Indices
The optical interface design and optical module chosen are according to the
requirements of BS EN 60825-2-2000.
Racks Stability
13
The layout of the rack shall maintain the overall symmetry. Under the premise to ensure
the performance indices and thermal design requirements, the gravity center shall be
lowered as much as possible to improve the overall stability. In normal conditions, the
equipment shall not be inverted on a 10 degrees tilt platform. The shell of the equipment
must be able to resist some external percussion. The case, shelves, and shell must be
fixed reliably, without the tendency to scatter.
Security protection grade is IP20 (2indicates that prevents the object which is bigger
than 12mm such as finger to insert into. And 0 indicates that has no special water
protection)
Such test can be done by using the integrity rack shell of sample or the other biggest
area of not enhanced part: one 500g steel ball will free fall from 1.3m height to hit the up
surface of the equipment, the case has no clearly indent. Or the 500g steel ball with
1.3m line as a horizontal pendulum to hit the beside surface of the equipment, if there is
indent damage or scratch, but it does not affect security, water resistant, and it also
can endure corresponding anti- electric strength, this test is passed.
Lightning Protection
The system provides lightning protection measures. The working ground and the
protection ground are reliable with the grounding resistance of the protection ground less
than 1 ohm. The protection grounding terminals are anti-corrosive; the insulating layer of
the grounding conductor is yellow-green. There is tooth-shape washer for the connection
between the protection ground and the screw of shell (or PCB) to make the protection
group more reliable and stable.
Current leakage
Security Marks
A clearly and long term sticky tags or marks must be labeled to ensure no mistake of
wrong board and cable connection. It has indicator, switch and button and mark with
clear color to indicate the meaning of the system running status.
The case can resist heat and flame. The outside case and clapboard between shelves
are all made of flame proof, heat resistance and explosion prevention material. All
material and units has the flame proof level better than V-2 or HF-2.
Input Current
Under the condition of rated input voltage, the input current shouldnt be more than110%
of rated current.
14
Abnormal Situations
RNC has no danger at the situations of overload, output short circuit, power in reverse,
fan locked and other man-made faults caused by mistake operations.
The components bridged at the normal position will not be damaged if the 1000Vac
grounding insulation between the telecom network circuits and grounding components is
not punctured.
As for TNV-1 circuit, whether it can be connected or not, it meets the requirements of the
stable anti-electric strength of network voltage protection.
Anti-earthquake performance
Installation
Figure 5 shows the installation flow of ZXWR RNC hardware.
15
Figure 5
The workload of the hardware installation is large and complex. It can fall into the
following parts:
1
Installing cabinet
ZXWR RNC adopts 19-inch standard cabinet. The cabinet installation includes base
installation mode and feet installation mode. In the case of multi-cabinet, fix a single
cabinet first and then connect the cabinets.
2
Installing boards
Usually, the shelf is installed inside the rack before delivery. The users are only required
to install boards and other accessories on the site.
3
16
Installing cables
After installing the cabinet, cables are required to install, including cabinet power cable,
cabinet grounding cable, intra-cabinet line, out-of-cabinet line, and inter-cabinet line.
4
GPS serves as the clock and frequency reference of WCDMA, playing a very important
role. In addition, it provides the system with GPS ephemeris signals for AGPS location.
GPS antenna receives the navigation location signals from the GPS satellite, modulating
into the frequency, clock signals and AGPS messages via the GPS signal receiver. The
clock signals are provided to WCDMA units and AGPS messages are sent to the
processing unit.
5
Installing accessories
After installing the cabinet, accessories related to RNC operation are required to install,
including the alarm box and all kinds of sensors.
6
Check the installation of ZXWR RNC hardware completely after it ends. The check
includes the cabinet installation techniques, cable connection and layout, auxiliary
device and related items.
7
After checking the installation, please power on/off the equipment for check.
17
18
Item
Explanation
Iu
Iub
Iur
Uu
Node B