You are on page 1of 1

9"

12#-8Nos.

9"

COLUMN C-1

COLUMN C-2

18"

18"

25#-8Nos.

#8-6"C/C
RINGS

#8-6"C/C RINGS

COLUMN SECTION
C-1

COLUMN SECTION
C-2

12#-8Nos.

25#-8Nos.
#8-6"C/C RINGS

#8-6"C/C RINGS

COLUMN SIZE-9"X18"

COLUMN SIZE-9"X18"

SIZE OF PEDESTAL 3'X3'

SIZE OF PEDESTAL 3'X3'

12#-13NOS. BOTHWAYS.

12"

12"

12#-13NOS. BOTHWAYS.

18"
6"

6"

SIZE OF FOOTING 5'x5'

18"

18"

SIZE OF FOOTING 5'x5'


18"

5'

5'

FOUNDATION SECTION

FOUNDATION SECTION

25#-8 NOS.

18"

18"

COLUMN C-4

25#-12 Nos.

RINGS 8#-6" C/C

18"

18"

COLUMN C-3
RINGS 8#-8" C/C

COLUMN SECTION

25#-12 NOS.

25#-8 NOS.

C-3

COLUMN SECTION
C-4

RINGS 8#-8"C/C

RINGS 8#-6"C/C

COLUMN SIZE 18"X18"

COLUMN SIZE 18"X18"

SIZE OF PEDESTAL 3'6"X3'6"

SIZE OF PEDESTAL 3'6"X3'6"

12#-15NOS. BOTHWAYS.

18"

18"

12#-15NOS. BOTHWAYS.

6'

6'

Size of footing 6'X6'

Size of footing 6'X6'

FOUNDATION SECTION

18"

FOUNDATION SECTION

COLUMN C-5

25#-16 Nos.

RINGS 8#-6" C/C

18"

25#-16 NOS.

COLUMN SECTION
C-5

RINGS 8#-6"C/C
COLUMN SIZE 18"X18"

SIZE OF PEDESTAL 4'X4'

18"

12#-17 NOS. BOTHWAY

12"

18"

12"

18"

18"

12"

7'

Size of footing 7'X7'


FOUNDATION SECTION

GENERAL NOTES:1.All Dimensions are in inches and feet unless noted otherwise.
2.Grade of concrete mix shall be M:20 conforming to IS:456-2001
3.Reinforcement shall be high strength deformed bars of Grade Fe:415
confirming to IS:1786- 1985.
4.Cover to reinforcement shall be as follows:Foundation
- 50mm
Column
- 40mm
Slab
- 15mm
Beam
- 25mm
5.Not more than half the column bars shall be lapped at a section.
6.Lap length shall be 50 times the diameter of bar.
7.Lap in Slab and Beams of superstructure close to mid-span for bottom bars
and close to support for top bars shall be avoided.
8.Ties/Rings/Distribution reinforcement shall be provided of 8#-8" c/c
otherwise mentioned.
9.Shear Key shall be left at column beam joint.
10.Camber @4mm per metre shll be provided in beams.
1
11.Cantilever shuttering shall be lifted by 50
th of projected length.

You might also like