You are on page 1of 4

Project

(144) Madinah

Building STORE
Subject

Footing Punching Check

Designer

M.SEYAM

Checked

M.AMAM

REV

FOOTING: F1

CODE: ACI 318

Fc': 25 MPa

: 0.75

d = 400 - 16 - 8 - 50 = 326 mm
Footing Area = 2.3 X 2.3 = 5.29 m2
Punching Area = (0.55 + 0.326) X (0.55 + 0.326)= 0.767376 m2
Punching perimeter = 2(0.55 + 0.326) + 2(0.55 + 0.326)= 3.504 m

pun. =

q act. (A footing - A pun.)


bo pun. X d
232.44 X (5.29 - 0.767376)
3.504 X 0.326

[ 9.3.2.3 ]

= 920.28 KN/m2

q allowable = 0.33 Fc' x bo pun. x d


=[ 0.75 X 0.33 X 25 X 3.504 X 0.326] 10^3 = 1413.61KN/m2

183.93 213.97

p pun. < q all.


OK, no punching

act. =

Err:5

= 232.44 KN/m2

Env. Load Com


1.4DL

SEYAM EXCEL

page

date

3/21/2016

ACI 318M-11M
25 MPa
0.75

[ 9.3.2.3 ]

250.91 280.94

Err:511
2
232.44 KN/m2

Env. Load Combination


1.4DL

You might also like