You are on page 1of 72

Operator Logo

ZXMP S385 V2.50


Product Description

ZXMP S385 V2.50 Product Description

ZXMP S385 V2.50 Product Description


Version

Date

Author

Approved By

Remarks

R0

2009-09-20

ZhangQiSheng

WangQiang,QinYong

Not open to the Third Party

R1

2010-05-20

LiXiongFei

WangQiang,QinYong

Not open to the Third Party

2011 ZTE Corporation. All rights reserved.


ZTE CONFIDENTIAL: This document contains proprietary information of ZTE and is not to be
disclosed or used without the prior written permission of ZTE.
Due to update and improvement of ZTE products and technologies, information in this document
is subjected to change without notice.

ZTE Confidential Proprietary

2011 ZTE Corporation. All rights reserved.

ZXMP S385 V2.50 Product Description

TABLE OF CONTENTS
1

Overview ................................................................................................................... 1

2
2.1
2.2
2.3
2.4
2.5
2.6

Features .................................................................................................................... 2
Flexible networking & dispatching function raises profit-making ability and reduces
CAPEX ...................................................................................................................... 2
Superior scalability protects CAPEX and reduces OPEX .......................................... 2
Leading RPR function supports IP evolution and protects CAPEX ............................ 2
Powerful embedded WDM function saves fiber resource .......................................... 2
Flexible design facilitates network planning & optimization........................................ 2
Wide application, mature technology and high reliability............................................ 2

3
3.1
3.2
3.2.1
3.2.2
3.2.3
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
3.12

Functions.................................................................................................................. 4
Cross-connection and extension capabilities ............................................................. 4
Powerful Service Access Ability................................................................................. 4
Optical Interfaces ...................................................................................................... 4
Electrical Interfaces ................................................................................................... 5
Data Interfaces .......................................................................................................... 5
Integrated WDM Function .......................................................................................... 6
Complete Equipment Protection Ability...................................................................... 6
Perfect Network Protection Ability ............................................................................. 7
Reliable Timing Synchronization Processing ............................................................. 7
System control and communication ........................................................................... 8
Overhead Processing ................................................................................................ 8
Easy For Maintenance And Upgrade ....................................................................... 10
Alarm input/output ................................................................................................... 10
System power supply .............................................................................................. 10
Perfect EMC and Operation Safety ......................................................................... 11

4
4.1
4.1.1
4.1.2
4.2
4.3

System Architecture .............................................................................................. 12


Product Physical Structure ...................................................................................... 12
System architecture ................................................................................................. 12
System mapping structure ....................................................................................... 13
Hardware Architecture ............................................................................................. 14
Software Architecture .............................................................................................. 15

5
5.1
5.1.1
5.1.2
5.1.3
5.2
5.3
5.4
5.5
5.6
5.7
5.7.1
5.7.2
5.7.3
5.7.4
5.7.5
5.8

Technical Specifications ....................................................................................... 17


Physical Indices ....................................................................................................... 17
Subrack and cabinet appearance ............................................................................ 17
Subrack backplane .................................................................................................. 18
Fan plug-in box ........................................................................................................ 18
Appearance and dimensions ................................................................................... 19
System subrack and slot diagram ............................................................................ 21
System board list and description ............................................................................ 22
STM-N optical interfaces performance .................................................................... 26
PDH interfaces performance and indexes ............................................................... 27
Performance of data boards .................................................................................... 29
Performance of SEE ................................................................................................ 29
Performance of TGE2B ........................................................................................... 29
Performance of RSEB ............................................................................................. 31
Performance of AP18 ............................................................................................ 32
Performance of TGSA8 ......................................................................................... 33
Physical Performance of Ethernet ........................................................................... 33

II

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

5.8.1
5.8.2
5.9
5.10
5.11
5.12
5.13
5.14
5.14.1
5.14.2
5.14.3
5.14.4
5.14.5
5.14.6
5.15

Ethernet interface types and followed standard ....................................................... 33


GE interface types and followed standard ............................................................... 36
Performance of OAD ............................................................................................... 38
Performance of OBA ............................................................................................... 39
Performance of OPA ............................................................................................... 40
Performance of DCM ............................................................................................... 41
Error Performance ................................................................................................... 42
Jitter index at interfaces ........................................................................................... 42
Jitter and wander tolerance of PDH input interface.................................................. 42
Jitter and wander tolerance of SDH input interface.................................................. 44
Inherent output jitter of STM-N interface .................................................................. 46
Mapping jitter of PDH tributary................................................................................. 47
Combined Jitter ....................................................................................................... 47
Jitter transfer function of the regeneration relay....................................................... 48
Clock timing and synchronous characteristics ......................................................... 48

6
6.1
6.2
6.3
6.3.1
6.3.2
6.3.3
6.3.4
6.3.5
6.4

Environment Adaptability...................................................................................... 51
Power supply requirements ..................................................................................... 51
Grounding requirements .......................................................................................... 51
Environment requirements ...................................................................................... 52
Operation Environment ............................................................................................ 52
Environment for Storage .......................................................................................... 53
Cleanness requirements .......................................................................................... 54
Bearing Requirements of the Equipment Room....................................................... 54
Electronic Static Discharge (ESD) ........................................................................... 55
Safety requirements ................................................................................................ 57

Glossary ................................................................................................................. 60

ZTE Confidential Proprietary

2011 ZTE Corporation. All rights reserved.

III

ZXMP S385 V2.50 Product Description

FIGURES
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14

ZXMP S385 functional block diagram ........................................................................ 12


Appearance of S385 Sub-rack................................................................................... 13
Multiplexing/mapping structure adopted by ZXMP S385 ........................................... 13
Functional relationships of the hardware platforms .................................................... 14
Hierarchical structure diagram of NM software .......................................................... 16
Subrack structure diagram......................................................................................... 17
Structure of fan box ................................................................................................... 18
Fan box structure....................................................................................................... 19
Board slot layout of sub-rack ..................................................................................... 22
The jitter and wander tolerance at E1 PDH input interface ........................................ 43
The jitter and wander tolerance at T1 PDH input interface ........................................ 43
The jitter tolerance of STM-N terminal multiplexer input interface.............................. 45
The input jitter tolerance of STM-N SDH regenerator ................................................ 46
The jitter transfer characteristics of a regeneration relay ........................................... 48

TABLES
Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7
Table 8
Table 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Table 16
Table 17
Table 18
Table 19
Table 20
Table 21
Table 22
Table 23
Table 24

IV

Optical Interfaces Provided by ZXMP S385 ................................................................. 5


Electrical Interfaces Provided by ZXMP S385 ............................................................. 5
Ethernet services Provided by ZXMP S385 ................................................................. 6
Equipment level protection provided by ZXMP S385 ................................................... 7
Overhead-Byte Usage List........................................................................................... 9
Dimensions and weights of structural parts ............................................................... 19
ZXMP S385 own configuration .................................................................................. 20
ZXMP S385 is configured with other products ........................................................... 20
Boards/unit list (with power consumption) ................................................................. 22
Performance of the STM-1 optical interface............................................................... 26
Performance of the STM-4 optical interface............................................................... 26
Performance of the STM-16 optical interface............................................................. 26
Performance of the STM-64/OTU2 optical interface of ZXMP S385 .......................... 27
Performance of the PDH electrical interface .............................................................. 27
Input port permitted attenuation, frequency deviation and output port signal bit rate
tolerance.................................................................................................................... 28
Requirements for the input/output port reflection attenuation .................................... 28
Performance of TGE2B of ZXMP S385 ..................................................................... 30
Ethernet interface index ............................................................................................. 33
Transmission index of FE MMF optical interface ....................................................... 34
Receiver index of FE MMF optical interface .............................................................. 34
index of FE short distance SMF optical interface ....................................................... 35
receiver index of FE short distance optical interface .................................................. 35
Transmission index of FE long distance SMF optical interface .................................. 35
Receiver index of FE long distance optical interface ................................................. 36

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 25
Table 26
Table 27
Table 28
Table 29
Table 30
Table 31
Table 32
Table 33
Table 34
Table 35
Table 36
Table 37
Table 38
Table 39
Table 40
Table 41
Table 42
Table 43
Table 44
Table 45
Table 46
Table 47
Table 48
Table 49
Table 50
Table 51
Table 52
Table 53
Table 54
Table 55
Table 56
Table 57
Table 58
Table 59
Table 60
Table 61
Table 62
Table 63
Table 64
Table 65
Table 66
Table 67

GE interface index ..................................................................................................... 36


Transmission index of GE MMF optical interface ....................................................... 36
Receiver index of GE MMF optical interface .............................................................. 37
Transmission index of GE short distance SMF optical interface ................................ 37
Receiver index of GE short distance optical interface ................................................ 37
Transmission index of FE long distance SMF optical interface .................................. 38
Receiver index of GE long distance optical interface ................................................. 38
Performance of OADD ............................................................................................... 39
Performance of OADC ............................................................................................... 39
Performance of OBA Module ..................................................................................... 40
Performance of OPA Module ..................................................................................... 40
Performance of the DCM ........................................................................................... 41
SDH system error performance ................................................................................. 42
The input jitter and wander tolerance of PDH interface.............................................. 43
The output jitter and wander tolerance of the PDH interface ..................................... 44
Input jitter and wander tolerance (UIP-P) of SDH ...................................................... 45
Input jitter and wander tolerance of the SDH ............................................................. 45
Input jitter tolerances of STM-N regenerators ............................................................ 46
STM-N interface inherent output jitter indexes of SDH .............................................. 46
STM-N network interface output jitter indexes of SDH ............................................... 47
Mapping jitter specifications....................................................................................... 47
Combined jitter .......................................................................................................... 47
Jitter transmission parameters of a regeneration relay .............................................. 48
The SEC Index list ..................................................................................................... 49
The wander limit value under constant temperature (MTIE) ...................................... 49
The wander limit value under temperature impact (MTIE) ......................................... 49
The wander limit value under constant temperature (TDEV) ..................................... 49
Climate requirement .................................................................................................. 52
Density requirements for chemical active substances ............................................... 52
Density requirements for mechanical active substances ........................................... 53
Requirements for mechanical stress.......................................................................... 53
Climate requirement .................................................................................................. 53
Requirements for mechanical stress.......................................................................... 54
Static discharge anti-interference .............................................................................. 55
RF electromagnetic radiated susceptibility ................................................................ 55
Electrical fast transient burst susceptibility at the DC power port ............................... 56
Electrical fast transient burst susceptibilities at the signal cable and control cable
ports .......................................................................................................................... 56
Surge susceptibility of DC power ............................................................................... 56
Surge susceptibility of the outdoor signal cable ......................................................... 56
Surge susceptibility of the indoor signal cable ........................................................... 56
Conductivity susceptibility of RF field......................................................................... 57
Conductive emission electromagnetic interference at the direct current port ............. 57
Radioactive emission electromagnetic interference ................................................... 57

ZTE Confidential Proprietary

2011 ZTE Corporation. All rights reserved.

ZXMP S385 V2.50 Product Description

Overview
ZXMP S385 is an optical transmission platform newly released by ZTE. ZXMP S385
targets the backbone or large capacity convergent layer of network which can satisfy
present and future network requirements. It is an ideal transmission system in
constructing broadband transmission networks.
ZXMP S385 provides rich service access functions and complete protection mechanism,
facilitating its wide applications.
ZXMP S385 adopts modular design, incorporating SDH, Ethernet, ATM, PDH and other
technologies. It can transmit voice and data services efficiently on the same platform.
This document is based on ZXMP S385 V2.50.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

ZXMP S385 V2.50 Product Description

Features

2.1

Flexible networking & dispatching function raises


profit-making ability and reduces CAPEX
It has high-integration service interface boards to access a lot of PDH, SDH and data
services.

2.2

Superior scalability protects CAPEX and reduces


OPEX
ZXMP S385 can be constantly evolved and upgraded. The user will just add or replace
boards to expand the network capacity, which will reduce CAPEX of the expansion
project.It adapts itself to the characteristics of metro services to maximize the equipment
investment return of clients.

2.3

Leading RPR function supports IP evolution and


protects CAPEX
It has powerful data service processing function. It supports two rings working at the
same time, unicast/multicast/broadcat services and bandwidth statistical multiplexing. It
features high bandwidth utilization rate, fast service provision, service priority access
control and fair mechanism and high QOS. It supports the RPR multi-ring spanning in
the networking and avoids service termination & conversion to reduce faulty points.

2.4

Powerful embedded WDM function saves fiber


resource
It can add/drop wavelength-level optical signals.

2.5

Flexible design facilitates network planning &


optimization
The boards can be inserted into any slot and flexible design facilitates service
configuration, maintenance and network planning & optimization.

2.6

Wide application, mature technology and high


reliability

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Due to mature technology and superior performance, ZXMP S385 is widely deployed in
major carriers and private networks as well as other countries and regions, e.g., Korea,
Pakistan, Morocco and Vietnam.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

ZXMP S385 V2.50 Product Description

Functions

3.1

Cross-connection and extension capabilities


Cross Clock board (CSF/CSE/CSA) of ZXMP S385 provides the cross-connect function
and fulfill the straight-through, broadcast, add/drop, and cross-connection of services.
CSF board implements high-order and low-order cross-switching functions. CSF has a
space-division switching capacity of 1536 1536 VC4. In which, 256256 VC4s are
assigned to the time-division cross-connect service unit, the others are allocated to the
space-division cross-connect unit of the system.
CSE board implements high-order and low-order cross-switching functions. CSE has a
space-division switching capacity of 1152 1152 VC4. In which, 256256 VC4s are
assigned to the time-division cross-connect service unit, the others are allocated to the
space-division cross-connect unit of the system.
CSA board implements high-order and low-order cross-switching functions. CSA has a
space-division switching capacity of 256 256 VC4. In which, 3232 VC4s are assigned
to the time-division cross-connect service unit, the others are allocated to the spacedivision cross-connect unit of the system.
The equipment can supports maximum 14 service slots and access a large amount of
PDH, SDH and data services.
It can process 176-path ECC, and support the network topologies as linear, ring, hinge,
ring with chain, tangent ring and cross ring of STM-N levels meeting the complex
networking requirements thoroughly.

3.2

Powerful Service Access Ability


ZXMP S385 adopts modular structure, with its hardware including cross-connect card,
clock card, control card, service card and service interface card. The service access
capacity is shown in following table.
A single sub-rack of ZXMP S385 has 14 slots for service boards and 10 slots for
interface boards. The equipment can access a large amount of PDH, SDH and data
services at one time.

3.2.1

Optical Interfaces
ZXMP S385 provides five types of optical interfaces: OTU2, STM-64, STM-16, STM-4
and STM-1, as shown in Table 1 .

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 1

Optical Interfaces Provided by ZXMP S385

Board Type

Rate (Mbit/s)

Board Integration
(channel/board)

Maximum Access Quantity

OTU2

10709.225

14

STM-64

9953.280

1/2

14/28

STM-16

2488.320

4/8

56/72

STM-4

622.080

1/2/4

56

STM-1

155.520

2/4/8/16

208

ZXMP S385 has the one-interface OTU2 optical line board to support AFEC or G.709
standard FEC function. By increasing the line rate, the board can correct the bit errors in
the line transmission. It may increase the receiving sensitivity by about 2dB or the OSNR
tolerance by 5-7dB, and work with OBA+OPA and Dispersion Compensation Module
(DCM) to implement the LH transmission without electrical regeneration.
ZXMP S385 also provides OTU2/STM-64/STM-16 colored interfaces comply with ITU-T
G.692 and ITU-T G.695, which can be connected to DWDM/CWDM directly without the
OTU board.
ZXMP S385 provides OTU2/STM-64/STM-16 DWDM wavelength interface with ITU-T
standard 50GHz grid in C-band.

3.2.2

Electrical Interfaces
ZXMP S385 provides STM-1 electrical interface and PDH electrical interfaces, as listed
in Table 2
Table 2

3.2.3

Electrical Interfaces Provided by ZXMP S385

Board Type

Rate (Mbit/s)

Board Integration
(channel/board)

Maximum Access Quantity

STM-1

155.520

4/8/16

208

E3

34.368

96

T3

44.736

96

E1

2.048

63

1260

T1

1.544

63

1260

Data Interfaces
There are several data boards in ZXMP S385 V2.50:SEE,TGE2B, RSEB, AP18 and
TGSA8, as shown in Table 3 .
SEE board provide 810M/100M+2GE Ethernet services which support L2 switching
function and EPS protection function.
TGE2B board provides 2GE adaptive Ethernet services.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

ZXMP S385 V2.50 Product Description

RSEB board provides 810M/100M+2GE interfaces which employs the bandwidth of


SDH/MSTP ring network to provide the dual-ring topology and implement the ring
interconnection of RPR nodes.
FE Ethernet interfaces of each Ethernet board above can be optical or electrical. It
provides FE optical interface via ESFE8 and optical interface via OIS18 respectively.
10M/100M optical or electrical interfaces are available via replacing interface board.
AP18 board is mainly used to converge or aggregate ATM service to SDH transmission
network. It provides 8155 Mbit/s optical interfaces at the ATM side and 1622 Mbit/s
non-concatenation data flow at the system side.
TGSA8 board supports 8 user interfaces which adopt SFP optical module. The first 4
user interfaces may respectively offer GE or SAN service. SAN service includes 1G
Fiber Channel and 1G FICON services. The other 4 user interfaces may offer 4GE
services.
Table 3

3.3

Ethernet services Provided by ZXMP S385

Board Name Interface Type

Board
Integration
(channel/board)

Maximum Access
Capacity

SEE

810M/100 M +2GE

8+2

128+32

TGE2B

2GE

56

RSEB

810M/100 M +2GE

8+2

128+32

AP18

8155 Mbit/s

112

TGSA8

(4SAN+4GE) or 8GE

(4+4) or 8

(56+56) or 112

Integrated WDM Function


ZXMP S385 has OAD (Optical Add/Drop) board to add/drop or multiplex/demultiplex 4
fixed-wavelengths of optical signals.
OAD board consists of two types in all: OADD is for DWDM signals and OADC is for
CWDM signals.
ZXMP S385 optical line board has DWDM or CWDM optical interfaces, and OAD board
can add/drop DWDM or CWDM optical signals. Both of them work together to actualize
OAD interface function.
ZXMP S385 single sub-rack supports at most 56 channels of DWDM OAD interfaces or
56 channels of CWDM OAD interfaces. ZXMP S385 V2.50 extension sub-rack can
support at most 56 channels of DWDM OADM interfaces or 56 channels of CWDM
OADM interfaces.

3.4

Complete Equipment Protection Ability


Table 4 shows the equipment level protection of ZXMP S385.

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 4

Equipment level protection provided by ZXMP S385

Items protected

Protection scheme

E1/T1 processing board

1:N (N9) tributary protection switching (TPS)

E3/T3 processing board

1:N (N4) TPS

STM-1 processing board(except


OEL116 board)

1:N (N4) TPS

FE board

1:N (N4) TPS

CSF/CSE/CSA(Cross-switch
and Synchronous-clock board)

1+1 hot backup

NCP/ENCP board

1+1 hot backup

48 V power interface board

1+1 hot backup

ZXMP S385 supports the co-existence of several different TPS protection.


ZXMP S385 adopts a dual-bus hierarchical design for service bus, overhead bus and
clock bus, which improves system reliability and stability.

3.5

Perfect Network Protection Ability


In terms of the network level protection, ZXMP S385 supports multiplex section
protection (MSP) ring, linear MSP, unidirectional path switched ring (UPSR), subnet
connection protection (SNCP) and logical subnet protection (LSNP), etc.
ZXMP S385 can implement all networking features recommended by ITU-T. It supports
the route reconstruction of Ethernet and IP, and meets IEEE802.3E.

3.6

Reliable Timing Synchronization Processing


The clock timing/synchronization unit is composed of Cross Clock board (CSF/CSE/CSA)
and SCI board. The unit completes system timing and network synchronization. It
implements the following functions:

Providing system clock signals and system frame header signals for all the units of
the SDH equipment.

Providing overhead bus clock and frame header

Providing the corresponding interface for upper-level controller to configure and


monitor the clock unit.

SCI board of ZXMP S385 provides four external reference clock output and four external
reference clock input. The interface type is 2Mbit/s or 2MHz.
SCI can be configured with four external 2.048M clock input references and 28 lines (or
tributary) 8K timing input references. Synchronization can select external clocks, line
clocks or E1/T1 tributary clocks.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

ZXMP S385 V2.50 Product Description

The protection switching of clock reference sources bases on the alarm information and
clock synchronization status message (SSM) algorithm-based automatic switching.
ZXMP S385 provides E1 tributary re-timing function. It supports synchronous priority
switching based on the SSM algorithm, optimizes synchronous timing distribution of the
network, prevents the occurrence of timing loops and keeps network synchronization the
optimal status.
A software-controlled or a hardware phase lock circuit is used to implement four working
modes: a. Fast pull-in; b. Locked; c. Holdover; d. Free run.

3.7

System control and communication


The Net Control Processor (NCP) and Enhanced Net Control Processor (ENCP)
implement the system control and communication function, which includes sending the
configuration commands to all MCUs via S interface and collecting their performance
and alarm information.
With ENCP, the extension subrack can be accessed.
NM information intercommunicates between NEs via the ECC channel.
The order-wire board (OW) performs the order-wire function. It actualizes the
intercommunication of order-wire phones between NEs via E1 and E2 bytes. It employs
an independent CPU for order-wire and communicating with NCP processor via S
interface.
The Qx interface board is the communication interface between NE and subnet
management control center (SMCC). With Qx interface, NCP/ENCP can report to SMCC
the alarm and performance information of the NE and subnet and receive the commands
and configurations sent from SMCC to the NE and subnet. The f interface is the LMT
access interface of local NM, which is for the access management of portable PC.
The reset and ring trip are on the rack. Other interfaces are on QXI and SCI boards.
The NCP/ENCP boards monitor the fan plug-box of the NE. The power distribution unit
performs the over/under voltage monitoring of input voltage.
The alarm I/O: the NCP/ENCP boards offers 8-path external alarm switch quantity
interfaces, collects the alarm signal of NE and transmits it to the alarm box and the firstcabinet-in-a-row.
It offers 2-path switch quantity (UC) interface and may output 2-path switch quantity for
user.

3.8

Overhead Processing
The overhead process of ZXMP S385 is performed by NCP/ENCP board, OW board,
CSF/CSE/CSA board, optical line boards and ATM board.
ZXMP S385 supports overhead transparent transmission, i.e. low rate service signal and
overhead can transfer transparently in STM-16 frame. It greatly improves the network

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

construction flexibility, abates the tension of insufficient optical fiber resources, and
ensures the NM integrity and the NM information continuity.Overhead-Byte Usage List is
show in Table 5 .
Table 5

Overhead-Byte Usage List

Overhead
type

Overhead
name

ZXMP S385 application

A1, A2

Frame position indication for regeneration section,


A1:11110110,A2:00101000

J0

S385 may identify, set and transparent transmit J0


byte

Z0

Not applied

D1~D12

S385 may set DCC of D1~D3 or D1~D12, and support


the transparent transmission of D1~D12

E1, E2

S385 supports E1, E2 order wire telephone, as well as


E1, E2 transparent transmission.

F1

S385 provides F1 64kbps co-directional data interface,


and the transparent transmission of F1 byte

B1

Used for the error code monitor of regeneration


section

B2

Used for the error code monitor of MS

K1, K2

Used for the auto-protection switchover (APS)


command of MS

S1

b5~b8 used for synchronous status message

M1

Used for MS far-end difference indication

AU PTR

The rate adjustment on AU level

J1

Used for high-order path trace, able to be set

B3

Used for path error code monitoring

C2

Used for expressing the composition or maintenance


status of VC-3/VC-4/VC-4X, able to read and write

G1

Used for returning the status and performance of path


terminal to the path origin of VC3/VC4/VC4XC

F2, F3

Not applying

H4

Affording the general position indication to payload, as


well as the special payload Position (i.e. H4 may be
the multi-frame position indication of VC12 and VC2);
and performing VC3/VC4 virtual concatenation

K3

Not applied

N1

Not applied

V5

Providing the functions of error code test, signal mark


and channel status for VC1/VC2

J2

VC1, VC2 path trace byte, able to be set

N2

Not supported

RSOH/MSOH

AU pointer

POH

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

ZXMP S385 V2.50 Product Description

Overhead
type

3.9

Overhead
name

ZXMP S385 application

K4

Used for the virtual concatenation process of low-order


path

Easy For Maintenance And Upgrade


With the following functions, the system becomes more reliable, featuring good
maintainability and easy scalability:

3.10

It supports optical power monitoring functions.

It supports online loading and remote upgrading of card software (including FPGA
logic).

It provides the daily maintenance function. In case of a fault, it can quickly locate the
fault to the card level.

All cards provide the temperature monitoring function.

Pluggable optical module (SFP module, LC connector).

Alarm input/output
NCP/ENCP provides 8 external alarm Boolean value input interfaces and two control
output interface.
NCP/ENCP collects alarm indication signals from NEs and sends them to the alarm box
and the first cabinet of the line. There are four alarm output interfaces.
The system provides two user alarm output interfaces and level alarms. It shares a DB9
interface with F1 interface at the backplane side.

3.11

System power supply


ZXMP S385 equipment employs the dual-power system to access the -48V power in the
equipment room and distributes the -48V DC power in the power distribution box.
It adopts separate power supply mode. No power boards in the sub-rack, the -48V
power directly powers each board via the MB board through a DC/AC conversion
module.
Two lines of independent external -48V DC power supply, -48VGND and the system
protection GND are led from the connectors on the distribution frame and then
connected to the sub-rack power distribution board. The power distribution (PD) board
provides the equipment with the following functions such as -48V power switch,
distribution, isolation, EMI filtering, protection against lightening and surge, fan power
supply and control

10

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

3.12

Perfect EMC and Operation Safety


EMC, operation safety and fire/explosion protection of the equipment are fully
considered in the circuit board design.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

11

ZXMP S385 V2.50 Product Description

System Architecture

4.1

Product Physical Structure

4.1.1

System architecture
ZXMP S385 functional block diagram is shown in Error! Reference source not found.
Figure 1

ZXMP S385 functional block diagram

ZXMP S385 SDH Based Multi-Service Node Equipment

SDH Equipment
(TM, ADM, REG)

ZXONM E300
EMS/SNMS

Security management

Maintenance
management

Performance
management

Fault
management

Configuration
management

System management

Sverice Acess
Platform

Power Support
Platform

Overhead Processing
Platform

Sverice Crossconnect Platform

Clock Processing
Platform

NE Control Platform

Hardware System

NE Management Software System

In terms of functional hierarchy, ZXMP S385 can be divided into hardware system and
network management (NM) software system, which are independent of each other and
work coordinately. The hardware system is the main body of the ZXMP S385. It can
work independently of the NM software system.
A standard "IEC cabinet + sub-rack" structure is used for ZXMP S385. Both the cabinet
and sub-rack unit are designed in the principle of front-facing installation and
maintenance to save equipment space and allow for back-to-back installation, frontfacing operations and maintenance. Appearance of S385 Sub-rack is show in Figure 2 .

12

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Figure 2

4.1.2

Appearance of S385 Sub-rack

System mapping structure


ZXMP S385 adopts the latest mapping structure of ITU-T recommendation, as shown in
Figure 3.
Figure 3

Multiplexing/mapping structure adopted by ZXMP S385

STM-N

AUG

AU-4

VC-4
3

Pointer processing

TUG-3

TU-3

VC-3
C-3

44736kbit/s
34368kbit/s

C-12

2048kbit/s

C-11

1544kbit/s

TUG-2
3

Multiplexing

TU-12

VC-12

Alignment
Mapping

VC-11

Note:
In above mapping structure, ZXMP S385 V2.00 and above version supports E1/T1,
E3/T3, STM-1 (optical/electrical), STM-4, STM-16, STM-64 and Ethernet services. V2.20

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

13

ZXMP S385 V2.50 Product Description

and later versions support SAN service. The service enters STM-N via AU-4
multiplexing/mapping route instead of AU-3 multiplexing/mapping route.
T1 service supports VC11-TU12 mapping route.

4.2

Hardware Architecture
With the platform design concept, the ZXMP S385 hardware system consists of the NE
control platform, clock processing platform, service cross platform, overhead processing
platform, power supply support platform and service access platform.
By means of platform establishment, transplant and integration, ZXMP S385 forms
different functional units or boards, which are connected in a specific way to form the
SDH equipment with perfect functions and flexible configurations. ZXMP S385 can be
configured as a TM, ADM, or REG equipment, depending on the networking
requirements. Configurations of REG at rates of 2.5G and 10G are available in V2.00
and above version.
The relationships of all the platforms are shown in Figure 4
Figure 4

Functional relationships of the hardware platforms

Service access
platform

Service crossconnect platform

.
.
.

Clock processing
platform

.
.
.

.
.
.

Overhead
processing
platform

Power supply
support platform

Service access
platform

.
.
.

NE control
platform

NE control platform
As the interface between NE equipment and background NMS, the NE control
platform is the agent for other platforms to receive or report network management
information.

Power supply support platform


With the distributed power supply style, power supply modules installed in each
board provide power to corresponding boards.

14

Service access platform

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

This platform supports the access of SDH, PDH, Ethernet, ATM and SAN services.
It converts accessed services to corresponding formats, and then forwards them to
the service cross platform for aggregation and distribution.
4

Overhead processing platform


This platform provides orderwire voice channel and some auxiliary data digital
channels through section overhead (SOH) bytes while transmitting payloads.

Clock processing platform


As one of the core part of the hardware system, this platform provides the system
clock for all platforms in the equipment.

Service cross platform


This platform receives service signals and various information from service access
platform and overhead processing platform, and implements service orientation and
information aggregation/distribution/switching.
ZXMP S385 backplane uses the unified service bus, clock bus, overhead bus and
control bus, and adopts the star structure centered on cross and clock board.

4.3

Software Architecture
ZXMP S385 employs ZXONM E300 to manage and monitor the hardware system and
transmission network, and coordinate the work of the transmission network.
1

Brief introduction to NM structure


ZXONM E300 system adopts four-layered structure, including equipment layer, NE
layer, NE management layer and sub-network management layer. It can also
provide Corba interface for the network management layer. The hierarchical
structure of ZXONM E300 system is shown in Figure 5 .

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

15

ZXMP S385 V2.50 Product Description

Figure 5

Hierarchical structure diagram of NM software

NE management scope
ZXONM E300 features forward and backward compatibility, capable of managing all
SDH-based multi-service node equipments.
ZXONM E300 V3.19 supports management of ZXMP S385 V2.50 version.

Function introduction
It can perform NE-layer network management functions such as configuration
management, fault management, performance management, security management,
system management, and maintenance management. Please refer to relevant
documentation of ZXONM E300 for details of NMS.

16

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Technical Specifications

5.1

Physical Indices

5.1.1

Subrack and cabinet appearance


The subrack adopts 19 high rack with dimension of 888.2mm (height) 482.6mm (width)
270mm (depth). It consists of side panels, beams and metal guide rails, with the
functions of heat dissipation and shielding. At the bottom of the subrack is a separate
fan plug-in box equipped with 3 independent fan module boxes, each fan module box
separately connects to fan backplane to facilitate maintenance. At the top of the subrack
a decoration door featuring decoration, ventilation and shielding functions can be
detached flexibly. ZXMP S385 Subrack structure diagram is show in Figure 6 .
Figure 6

Subrack structure diagram

1. Top outlet 2. Decoration door 3. Board area 4. Lower cabling area 5. Fan plug-in box
The subrack consists of four parts:
1

Backplane: the carrier for boards, connects ZXMP S385 to the connection interface
of external signals. The boards are connected to the buses via the board connection
sockets on the backplane.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

17

ZXMP S385 V2.50 Product Description

Plug-in board area: it is dual-layer structure used to install ZXMP S385 boards.

Fan plug-in box: located at the bottom of the subrack, it provides forced air cooling
for the equipment to dissipate heat.

The rear part of ZXMP S385 is equipped with one left and one right mounting lugs which
are used to fix the equipment subracks in the cabinet. ZXMP S385 subrack adopts back
fixing installation mode, it can be fixed in the cabinet from the front without obstructing
cable layout, satisfying requirements for front-facing installation, front-facing
maintenance, against wall and back-to-back installation of equipment cabinet.
ZXMP S385 cabinet is 19 cabinet compliant with ETSI standards. It is made of excellent
steel plate and features good electromagnetic shielding and heat dissipation
performances.

5.1.2

Subrack backplane
ZXMP S385 backplane is fixed at the subrack, serving the carrier for connecting all the
boards. It is divided into upper and lower parts, in which, the upper part connects various
functional interface boards, and the lower part connects various functional boards. The
backplane contains service bus, overhead bus, clock bus, board-in-position bus,
connects all the boards, equipment and external signals via interfaces and sockets.
Backplane adopts unified arrangement of bus arrays of payload services, auxiliary
services, internal board-to-board communication and clock, thus ensures the equipment
to add boards with various types of interfaces according to customers requirements.

5.1.3

Fan plug-in box


The structure of the fan plug-in box of the ZXMP S385 is shown in Figure 7. Three
independent fan boxes are installed in the fan plug-in box, the structure of fan box is
shown in Figure 8. Each fan module is electrically connected to the fan backplane via
the socket at the back of the box. The fan box features independent locking function. It
has running and alarm indicators on the front panel.
Figure 7

Structure of fan box

1.Fan box mounting bracket 2. Fan box

18

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Figure 8

Fan box structure

1. Fan box 2. Fan 3. Indicator 4. Button switch


The fan system of ZXMP S385 is the component for cooling and heat dissipation. Each
subrack contains a fan backplane and three independent fan units side by side. Each
fan unit is composed of a fan box, a fan and a FAN board. The FAN board is control by
ENCP and provides rotation-blocking signal for ENCP monitor. The FAN board controls
the fan operation if the FAN board loses contact with ENCP.

5.2

Appearance and dimensions


Dimensions and weight indexes of structural parts of ZXMP S385 are shown in Table 6
Table 6

Dimensions and weights of structural parts

Dimension (mm)

Weight
(kg)

2000 (height)600 (width)300 (depth)

70

2200 (height)600 (width)300 (depth)

80

2600 (height)600 (width)300 (depth)

90

ZXMP S385 sub-rack

888.2mm (height)482.6mm (width)270mm


(depth)

25

Power distribution
box

132.5 (height)482.6 (width)269.5 (depth)

Fan plug-in box

43.6mm (height)436mm (width)245mm


(depth)

--

Dustproof plug-in box

43.6mm (height)482.6mm (width)250 (depth)

Ventilation unit

43.6mm (height)482.6mm (width)250 (depth)

Upper cabling area

133 mm (height)482.6mm (width)250mm


(depth)

--

Cross-connect clock
board
(CSA/CSE/CSF)

PCB: 320 (height)210 (depth)2 (depth)


Front panel: 345.6 mm (height) 8 HP (width)

--

Structural part

ZXMP S385 cabinet

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

19

ZXMP S385 V2.50 Product Description

Structural part

Dimension (mm)

Weight
(kg)

Service interface
board and ENCP, OW

PCB: 277.8mm (height)160mm (depth)2mm


(width)
Front panel: None

--

Service board (lower


layer boards of subrack)

PCB: 320mm (height)210mm (depth)2mm


(width)
Front panel: 345.6 mm (height)5HP (width)

--

Note: The cabinet weight is the weight of an empty cabinet. 1HP=5.08 mm


ZXMP S385 offers cabinets with height of 2000mm, 2200mm and 2600mm. Subrack,
the core component, is installed in ZXMP S385 cabinet. A 2000mm-high cabinet can
accommodate only one subrack. A 2200mm- or 2600mm-high cabinet can
accommodate one or two subracks. Various functions of the equipment can be realized
via different configurations of subrack boards.
In accordance with current situation of transmission cabinet, overall structure layout can
be classified into 3 scenarios based on cabinet height, which are shown in Table
7 ,Table 8 .
Table 7

ZXMP S385 own configuration

Cabinet height

Power
distribution
box

Subrack

2.0m (with
effective height of
42U)

3U

20U+1U (subrack and cabling area+dustproof


plug-in box)

2.2m (with
effective height of
47U)

3U

20U+1U+1U+20U+1U (2 subracks and cabling


area+2 dustproof plug-in boxes+1 ventilation
unit)

2.6 m (with
effective height of
56U)

3U

20U+1U+1U+20U+1U (2 subracks and cabling


area+2 dustproof plug-in boxes+1 ventilation
unit)

Table 8

ZXMP S385 is configured with other products

Cabinet height

2.0m (with effective height


of 42U)

2.2m (with effective height


of 47U)

20

Power
distribution
box

Subrack

3U

ZXMP S385 (20U+2U)+ ZXMP S320


(4U+1U)

3U

ZXMP S385 (20U+2U)+ ZXMP S330


(10U+3U)

3U

ZXMP S385 (20U+2U)+ ZXMP S320


(4U+1U)

3U

ZXMP S385 (20U+2U)+ ZXMP S330


(10U+3U)

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Cabinet height

2.6m (with effective height


of 56U)

Power
distribution
box

Subrack

3U

ZXMP S385 (20U+2U)+ ZXMP S320


(4U+1U)

3U

ZXMP S385 (20U+2U)+ ZXMP S330


(10U+3U)

3U

ZXMP S385 (20U+2U)+ ZXMP S360


(21U+2U)

3U

ZXMP S385 (20U+2U)+ ZXMP S390


(23U+2U)

+1U,+2U,+3U in the table are space reserved for dustproof, ventilation and cabling.

5.3

System subrack and slot diagram


ZXMP S385 sub-rack includes board, fan plug-in box and dustproof unit.
Structure of sub-rack is shown in Figure 9.
The plug-in board area of ZXMP S385 is separated into 2 layers, where, the top layer is
for interface boards with 15 slots and the low layer is for functional boards with 16 slots.
The sub-rack bottom contains a 1U fan plug-in box that contains three fans working
independently.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

21

ZXMP S385 V2.50 Product Description

Figure 9

5.4

Board slot layout of sub-rack

System board list and description


Common board name (code), applying rule and unit power consumption of ZXMP S385
are shown in Table 9 .The maximum input current of subrack is 16A.
Table 9

22

Boards/unit list (with power consumption)

Board

Board name and


configuring explanation

Power
Consum
ption in
Common
Temperat
ure (25 )
(W)

Max.
Power
Consum
ption
(45 ) (W)

Weight
(Kg)

NCP

Net Control Processor, 1 for standard


configuration, 2 able to practice 1+1
protection

4.8

0.44

ENCP

Enhanced Net Control Processor, 1


for standard configuration, 2 able to
practice 1+1 protection

9.6

9.9

0.46

OW

Order-wire

5.3

5.4

0.47

QxI

Qx interface 1 for standard


configuration

3.9

4.1

0.52

CSA

Cross-switch and Synchronous-clock


(256x256 VC4 high order with 32x32
VC4 low order)

27.4

28.2

1.14

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Board

Board name and


configuring explanation

Power
Consum
ption in
Common
Temperat
ure (25 )
(W)

CSF

Cross-switch and Synchronous-clock


(1440x1440 VC4 high order)

32.4

33.4

1.46

TCS64

Cross-switch with low-order

17.3

17.8

0.56

TCS128

Cross-switch with low-order

36.5

37.6

0.95

TCS256

Cross-switch with low-order

60.5

62.3

0.98

SCIB

B-type clock interface board (2Mbit/s)

3.9

4.0

0.51

SCIH

H-type clock interface board (2MHz)

4.4

4.5

0.61

OL64FE
C

Optical Line of out2, with L-64.2cIf, L64.2c


IIf or L-64.2pf. Supports FEC function

25

27.3

1.12

OL64

Optical Line of STM-64, with S-64.2b,


L-64.2cI, L-64.2cII, P1L1-2D2 or L64.2p.

28.8

31.2

0.95

OL64x2

STM-642 optical line board. Optical


module types configurable include S64.2b, L-64.2c1, L-64.2c2 and L64.2p. Refer to ECC information for
details.

31.9

34.3

1.12

OL16

Optical Line of STM-16, with S-16.1,


L-16.2, L-16.2JE, L-16.2U or L-16.2P

14.9

16.3

0.65

OL164

Optical Line of STM-164, with S16.1, L-16.2 or L-16.2U

23.6

28.3

1.30

OL168

STM-168 optical line board. Optical


module types configurable include S16.1, L-16.2, L-16.2u and L-16.2p.
Refer to ECC information for details.

33.5

38.2

1.43

OL42

Optical Line of STM-42

10.1

10.4

0.70

OL44

Optical Line of STM-44

16.8

17.3

0.74

OL14

Optical Line of STM-14

8.9

9.2

0.74

OL18

Optical Line of STM-18

14.4

14.8

0.80

OEL116

Optical Line/Electrical Line Process of


STM-116

18.1

18.6

0.87

OEIS1x8

Optical /Electrical interface of STM18

6.4

6.4

0.38

LP14

Line Process of STM-14, used


together with electric interface
switchover board or bridge board

5.8

0.65

LP18

Line Process of STM-18, used


together with electric interface
switchover board or bridge board

5.8

0.68

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

Max.
Power
Consum
ption
(45 ) (W)

Weight
(Kg)

23

ZXMP S385 V2.50 Product Description

Board name and


configuring explanation

Power
Consum
ption in
Common
Temperat
ure (25 )
(W)

Max.
Power
Consum
ption
(45 ) (W)

Weight
(Kg)

4-path STM-1 electric interface


switchover board, used for interface
slot

Before
switchove
r 0.5,
after
switchove
r 8.2

Before
switchove
r 0.6,
after
switchove
r 8.4

0.40

ESS18

Electrical Interface of STM-14

Before
switchove
r 0.5,
after
switchove
r 8.2

Before
switchove
r 0.6,
after
switchove
r 8.4

0.47

EP36

Electrical Process of E3/T36

12.5

12.9

0.71

ESE36

Electrical Interface Switching of


E3/T36

Before
switchove
r 0.5,
after
switchove
r 5.3

Before
switchove
r 0.6,
after
switchove
r 5.4

0.40

BIE3

Bridge Interface of STM1e/E3/T3/FE,used for the interface


slot corresponding to protection board

0.5

0.6

0.37

EPE163
(75)

Electrical Process of E163 (75)

19

19.6

0.81

EIE163(
75)

Electrical Interface of E163 (75)

0.5

0.6

0.36

ESE163
(75)

Electrical Interface Switching of


E163 (75)

Before
switchove
r 0.5,
after
switchove
r 21.6

Before
switchove
r 0.6,
after
switchove
r 22.2

Before
switcho
ver 0.6,
after
switcho
ver 8.4

EPE163
(120)

Electrical Process of E163 (120)

19

19.6

0.83

EPT163
(100)

Electrical Process of T163 (100)

15.4

15.8

0.81

EIT163

Electrical Interface of T163 (100)


or E163 (120)

0.5

0.6

0.35

Electrical Interface Switching of


T163 (100) or E163 (120)

Before
switchove
r 0.5,
after
switchove
r 21.1

Before
switchove
r 0.6,
after
switchove
r 21.8

0.54

Board

ESS14

EST163

24

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Board

Board name and


configuring explanation

Power
Consum
ption in
Common
Temperat
ure (25 )
(W)

BIE1

Bridge Interface of E1/T1

0.5

0.6

0.39

SEE

Enhanced Intelligent Ethernet


Processing Board(48:1),customer
side 8FE(optical or electrical)+2GE

26.4

27

0.75

RSEB

Embedded RPR Ethernet Processing


Board, customer side 8FE(optical or
electrical)+2GE

29.4

30.3

0.98

AP18

8155Mbit/s optical board at the ATM


side and 1622Mbit/s nonconcatenation data flow at the system
side.

24.1

24.9

0.85

TGE2B

GE transparent process board

19.1

19.7

0.73

TGSA8

SAN service processing board,


customer side 4SAN+4GE or
8GE

36.5

37.6

0.99

OIS18

Optical interface board cooperating


with Ethernet board RSEB

7.0

7.2

0.45

OEIFEx8

Optical /electric interface board


cooperating with SEE board

8.5

8.5

0.45

ESFE8

Ethernet electric board cooperating


with Ethernet board including
RSEB/SEE

0.6

0.7

0.38

OADD

Optical add/drop unit board for 4


channels of fixed wavelength DWDM
optical signals.

4.1

0.75

OADC

Optical add/drop unit board for 4


channels of fixed wavelength CWDM
optical signals.

3.5

3.6

0.75

FAN

Fan board

4.2

4.3

0.36

OBA12

Optical Booster Amplifier


board(12dBm) built-in

6.1

11.6

1.15

OBA14

Optical Booster Amplifier


board(14dBm), built-in

6.1

11.6

1.15

OBA17

Optical Booster Amplifier


board(17dBm), built-in

6.1

11.6

1.15

OBA19

Optical Booster Amplifier


board(19dBm), built-in

6.1

11.6

1.15

OPA32

Optical Pre-Amplifier(-32dBm), builtin

4.8

10.3

1.18

OPA38

Optical Pre-Amplifier(-38dBm), builtin

4.8

10.3

1.18

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

Max.
Power
Consum
ption
(45 ) (W)

Weight
(Kg)

25

ZXMP S385 V2.50 Product Description

5.5

STM-N optical interfaces performance


Performance of the OTU2/STM-64/16/4/1 optical interfaces is shown in Table 10 ,Table
11 ,Table 12 ,Table 13 .
Table 10

Performance of the STM-1 optical interface

Nominal bit rate

155520kbit/s

Classification code

S-1.1

L-1.1

L-1.2

Working wavelength (nm)

1310

1310

1550

Source type

MLM

SLM

SLM

Min transmitting optical power (dBm)

-15

-5

-5

Max transmitting optical power (dBm)

-8

Minimum extinction ratio (dB)

8.2

10

10

Poorest sensitivity (dBm)

-28

-34

-34

Minimum overload point (dBm)

-8

-10

-10

Transmitter at reference point S


G.957-compliant

Optical path between Point S and R


Receiver at reference point R

Table 11

Performance of the STM-4 optical interface

Nominal bit rate

622080kbit/s

Classification code

S-4.1

L-4.1

L-4.2

Working wavelength (nm)

1310

1310

1550

Source type

MLM

SLM

SLM

Min transmitting optical power (dBm)

-15

-3

-3

Max transmitting optical power (dBm)

-8

Minimum extinction ratio (dB)

8.2

10

10

Poorest sensitivity (dBm)

-28

-28

-28

Minimum overload point (dBm)

-8

-8

-8

Transmitter at reference point S


Optical path between Point S and R

G.957-compliant

Receiver at reference point R

Table 12

26

Performance of the STM-16 optical interface

Nominal bit rate

2488320kbit/s

Classification code

S16.1

L16.2

L16.2JE

L16.2P

L16.2U

Working wavelength (nm)

1310

1550

1550

1550

1550

Source type

SLM

SLM

SLM

SLM

SLM

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Nominal bit rate

2488320kbit/s

Min transmitting optical power (dBm)

-5

-2

+2

-2

-2

Max transmitting optical power (dBm)

Minimum extinction ratio (dB)

8.2

8.2

8.2

8.2

8.2

Poorest sensitivity (dBm)

-18

-28

-28

-28

-28

Minimum overload point (dBm)

-9

-9

-9

-9

Transmitter at reference point S


Optical path between Point S and R

G.957-compliant

Receiver at reference point R

Table 13

Performance of the STM-64/OTU2 optical interface of ZXMP S385

Nominal bit rate

9953280kbit/s

10709225kbit/s

Classification code

S64.2b

L64.2c1

L64.2c2

P1L12D2

P1L1-2D2

Working wavelength (nm)

1550

1550

1550

1550

1550

Source type

SLM

SLM

SLM

SLM

SLM

Min transmitting optical power


(dBm)

-1

-2

Max transmitting optical power


(dBm)

Minimum extinction ratio (dB)

8.2

8.2

8.2

Poorest sensitivity (dBm)

-14

-22

-22

-24

-24

Minimum overload point (dBm)

-1

-9

-9

-7

-7

Transmitter at reference point S


Optical path between Point S
and R

G.709compliant

G.691 or G.959.1-compliant

Receiver at reference point R

5.6

PDH interfaces performance and indexes


Performance of PDH electrical interfaces is shown as Table 14 .
Table 14

Performance of the PDH electrical interface

Type

1544
kbit/s

2048
kbit/s

34368
kbit/s

44736
kbit/s

155520
kbit/s

Code pattern

AMI or
B8ZS

HDB3
code

HDB3
code

B3ZS
code

CMI code

G.703complia
nt

G.703complia
nt

G.703complian
t

G.703complian
t

G.703compliant

Bit rate of signals at output


port
Attenuation tolerance at
input port
ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

27

ZXMP S385 V2.50 Product Description

1544
kbit/s

Type

2048
kbit/s

34368
kbit/s

44736
kbit/s

155520
kbit/s

Frequency deviation
tolerance at input port
Anti-interference capability
of input port

Permitted input port attenuation, permitted frequency deviation and output port signal bit
rate tolerance are listed in the following Table 15 .
Table 15 Input port permitted attenuation, frequency deviation and output port signal bit rate
tolerance

Interface
rate

Permitted input port


frequency
deviation(regular
squared attenuation)

Permitted input port


frequency deviation

Output port rate


tolerance

1544kbit/s

--

Greater than 32ppm

Less than 32ppm

2048 kbit/s

0dB~6dB, 1024kHz

Greater than 50ppm

Less than 50ppm

34368
kbit/s

0dB~12dB, 17,184kHz

Greater than 20ppm

Less than 20ppm

44736
kbit/s

--

Greater than 20ppm

Less than 20ppm

155520
kbit/s

0dB~12.7dB, 78MHz

Greater than 20ppm

Less than 20ppm

Reflection attenuation at the input/output ports


For input/output port reflection attenuation index of various electronic ports of ZXMP
S385, please refer to Table 16 .

Table 16

Requirements for the input/output port reflection attenuation

Interface bit rate

2048Kbit/s input port

34368Kbit/s input port


155520Kbit/s input/output port

Test frequency
range

Reflection attenuation
(dB)

51.2kHz~102.4kHz

12

102.4kHz~2048kHz

18

2048kHz~3072kHz

14

860kHz~1720kHz

12

1720kHz~34368kHz

18

34368kHz~51550kHz

14

8MHz~240MHz

15

Anti-interference capability of the input port


The ratio of main signals to interference signals is 18dB.

28

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Output port waveform


The output port
Recommendation.

waveform

complies

with

template

specified

in

G.703

Over-voltage protection of the input and output interfaces


The input and output interfaces must bear 10 continuous standard pulses (5 positive
and 5 negative) without being damaged. The rising time of a standard pulse is 1.2s,
the width is 50s and the voltage amplitude is 20V.

5.7

Performance of data boards


There are several data boards in ZXMP S385 V2.50:SEE, TGE2B, RSEB, AP18 and
TGSA8.

5.7.1

5.7.2

Performance of SEE

Providing 810M/100M+2GE interfaces.

Support 48VCG. VCG mapping mode may be VC-12-Xv/VC-3-Xv/VC-4-Xv. VCG


supports at most 1.25G bandwidth.

The total mapping bandwidth of SDH backplane is 1.25Gbps.

Support E-Line, E-Tree and E-LAN services.

Configure S-VLAN according to port or customer CE-VLAN.

Support Ethernet OAM to facilitate fault locating and performance inspection.

Support GFP RDI-CSF alarm.

Support Ethernet access rate control and DifferServ.

Support EPS protection.

Support port dispatching fairness of best-effort service.

Performance of TGE2B
TGE2B board provides 2GE adaptive Ethernet services.The performance is show as
Table 17 .

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

29

ZXMP S385 V2.50 Product Description

Table 17

Performance of TGE2B of ZXMP S385

Characteristics of Ethernet board

Explanation of board function

Property sort

Board name

TGE2B

Ethernet port characteristics

1000BASE-SX/LX

Connector

LC

QTY of board interface

Port work mode (rate, full duplex


and auto-negotiation)

Support

Optical module able to plug

Support

Ethernet port

Interface
mode

Front-outlet on panel

Remote download and upgrade

Support

Max. Port QTY at system SDH side (WAN port)

2
2.5G

Total backplane mapping bandwidth

Virtual
concatenation

VC3 Virtual concatenation

Support (The delay supported by


VC3 is 8ms. The board adopts
the V3-AU3-AUG mode and the
mapping is not made via VC4.
Some problems occur in the
interconnection with other
vendors equipment and in the
test. The interconnection and test
adopt VC4 instead of VC3. )

VC4 Virtual concatenation

Support (The delay tolerance


supported by VC4 is 8ms.)

Dynamic VCG bandwidth


increase/decrease, no
damage with service

Support (The dynamic service


bandwidth adjustment leads to
100ms loss. There is no problem
in the function and
interconnection.)

LCAS management functions


(enable, alarm, event report)

Support

Multi-path protection of VCG


level, protecting time <300ms

Support

Support GFP encapsulation,


satisfy ITU-T G.7041 standard

Support

support LAPS protocol, satisfy


ITU-T X.86 standard

Support

support PPP encapsulation


protocol

Support

Support Jumbo frame

Support (maximum 9600 byte)

LCAS protocol

Encapsulation
protocol

30

Support 16VC4 (Each VCG


supports at most 8VC4), or
48VC3 (Each VCG supports at
most 24VC3).

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Characteristics of Ethernet board

Explanation of board function

Support the
flow control
based on port

Full duplex 802.3x PAUSE flow


control
Support port transparent
transmit, the service frame
format might be (Eth II, 802.3,
802.1QTAG)

Support. Support the transfer of


the port Link state to the opposite
end, and the Link State Transfer
technique (LST), which will
greatly reduce the switching time
of the router.

The transparent transmit


performance satisfies MSTP
recommendation, refer to
MSTP standard 6.2.1 for
details, key performance
parameters: package losing
rate, burst interval, transfer
rate, and delay

Support

The
intercommunic
ation of
different
products inside
company

VC4 level intercommunication

VC4-level intercommunicating
with EOS series boards, RPR
functional RSEB board

Ethernet
performance

Support Ethernet performance


monitor of port level

Support

Point-to-point
transparent
transmit
(private service
mode)

5.7.3

Performance of RSEB
RSEB maps Ethernet service to RPR, and performs the unique functions of RPR. It uses
the channel bandwidth resource of SDH/MSTP ring network to provide the dual-ring
topology required by RPR and implement the ring interconnection of RPR nodes.
RSEB provides user Ethernet interfaces as 8FE (optical/electrical) +2GE (optical). It
provides FE optical or electrical board by cooperating with OIS18 or ESFE interface
board respectively.
RSEB board provides two RPR ports and four EOS port at system side:

RPR at system side contains two RPR SPAN: RPR SPAN1 and RPR SPAN2 with
mapping methods of VC-4-Xv, VC-3-Xv, backplane bandwidth is 2.5G, capable of
constructing 1.25G RPR.

RPR board at system side provides four EOS ports with mapping method of VC-12Xv and a maximum bandwidth of 63VC12.

EOS system port can be used for RPR service cross-ring, or intercommunication with
EOS boards as SEE . It supports LCAS protocol.
RPR SPAN port and EOS system port share the 2.5 Gbit/s SDH processing bandwidth.
They support maximum 2.5 Gbit/s of RPR ring total bandwidth, and maximum 155 Mbit/s
ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

31

ZXMP S385 V2.50 Product Description

of EOS bandwidth (RPR ring total bandwidth and EOS bandwidth cannot reach the
maximum values simultaneously).
RSEB board has the following functions:

5.7.4

Switching capacity: 5G, backplane bandwidth:2.5G;

Providing 8FE+2GE user Ethernet interfaces;

Compliant with IEEE802.17, support for two RPR SPAN, capable of forming 1.25G
bidirectional ring at most;

Support for interoperation of RPR ring and EOS chain, implementing conversion of
mapping granules;

Support for Bypass RPR MAC function, used as EOS transparent transmission
board to support transparent transmission of two GE+4 FEs;

EOS port supporting CSF OAM function, with point-to-point LST function available;

Support for IGMP Snooping broadcast protocol, support for IPTV application;

Support for LACP protocol, providing large-capacity dynamic link aggregation


function with protection;

Good service security isolation, support for Q in Q-based VLAN VPN;

Support for VC-12-Xv/VC-3-Xv/VC-4-Xv, LCAS and GFP.

Performance of AP18
AP18 board is mainly used to converge or aggregate ATM service data to SDH
transmission network. It provides 8155 Mbit/s optical interfaces at the ATM side to
perform functions as ATM layer processing and mapping from ATM cell to VC-4. It
provides 1622 Mbit/s non-concatenation data flow at the system side. With 622M
backplane bandwidth and 622Mbps cell switching capacity, it can select 1-4 VC-4
channels to transmit ATM services.

32

Backplane bandwidth: 622M, cell switching capacity: 622Mbps.

Supports four ATM service types as constant bit rate (CBR), realtime variable bit
rate (rt-VBR), non-realtime variable bit rate (nrt-VBR) and unspecific bit rate (UBR).

Supports VP/VC switching.

Support VP uni-directional/bidirectional 1+1 and 1:1, supports VPRing, VCRing


functions.

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

5.7.5

Support OAM function of ATM, supports VP protection switching, the switching


request can be alarms as VP-AIS (Virtual path-based alarm indication signal), LOS
(loss of signal), LOF (loss of frame), OOF (out of frame), LAIS (line alarm indication
signal), LCD (loss of cell delineation), and LOP (loss of pointer).

Supports ATM space, logic multicast, when performing ATM exchange, it can copy
one input ATM cell flow (VP, VC) to multiple output ATM links.

Performance of TGSA8
TGSA8 has SAN and GE transparent transmission interface. It supports 8 user
interfaces which adopt SFP optical module. The first 4 user interfaces may respectively
offer GE or SAN service. SAN service includes 1G Fiber Channel and 1G FICON
services. The other 4 user interfaces may offer 4GE services.
TGSAx8 provides 42.5G service bus at the system side. The total bandwidth is 10G.
Other characteristics of TGSAx8 are showed as follows:

Support GFP and comply with G.7041.

Support LOF, OOF, AU-AIS and AU-LOP alarm check.

Provide line-side and user-side loopback functions of user interface.

Support VC-3 and VC-4 mixed concatenation. Any VCG may be respectively
configured to VC-3 or VC-4 virtual concatenation. VC-3 supports VC-3-->TU-3->AU-4 mapping path.

Support LCAS protocol and complies with G.7042.

5.8

Physical Performance of Ethernet

5.8.1

Ethernet interface types and followed standard


Ethernet interface index is show in Table 18 .
Table 18

Ethernet interface index

Type

Rate (bps)

followed
standard

Interface type

interface

10BASE-T

10M

IEEE 802.3

Electronic
interface

RJ45,
category 3
UTP

100BASE-TX

100M

IEEE 802.3u

Electronic
interface

RJ45,
category 3
UTP

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

33

ZXMP S385 V2.50 Product Description

Type

Rate (bps)

followed
standard

Interface type

interface

100BASE-FX

100M

IEEE 802.3u

M-1.1/S-1.1/L-1.1

SFP-LC

All optical interface indices are described as following table.


1

FE MMF optical interface(M-1.1)


FE MMF optical interface(M-1.1)as show in Table 19 ,Table 20 .

Table 19

Transmission index of FE MMF optical interface

Item

62.5/125m MMF

Transmission unit type

MMF LD

Transmission distance

Interface

SFP-LC

Unit
KM

Wavelength (, range)

1270~1380

nm

Trise/Tfall (maximum;10%~90%)

ns

RMS spectrum width (maximum)

63

nm

Output optical power (maximum)

-14

dBm

Output optical power (minimum)

-20

dBm

Output optical power when the LD is


shut down (maximum)

-45

dBm

Extinction ratio (minimum)

10

dB

Table 20

Receiver index of FE MMF optical interface

Item

62.5/125m MMF

Unit

Wavelength(, range)

1270~1380

Nm

input optical power (maximum)

-14

dBm

Receiver sensitivity

-30

dBm

FE short distance SMF optical interface(S-1.1)


FE short distance SMF optical interface(S-1.1) as show in Table 21 ,Table 22

34

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 21

index of FE short distance SMF optical interface

Item

10/125m SMF

Transmission unit type

SMF LD

Transmission distance

15

Interface type

SFP-LC

Wavelength(, range)

1261~1360

nm

Trise/Tfall (maximum;20%~80%)

2.5

ns

RMS spectrum width(maximum)

7.7

nm

output optical power(maximum)

-8

dBm

output optical power(minimum)

-11.5

dBm

Output optical power when the LD is


shut down(maximum)

-45

dBm

Extinction ratio(minimum)

dB

Table 22

Unit
KM

receiver index of FE short distance optical interface

Item

10/125m SMF

Unit

Wavelength (, range)

1261~1360

nm

Input optical power (maximum)

-8

dBm

Receiver sensitivity

-31

dBm

FE long distance SMF optical interface(L-1.1)


FE long distance SMF optical interface(L-1.1) as show in Table 23 ,Table 24 .

Table 23

Transmission index of FE long distance SMF optical interface

Item

10/125m SMF

Transmission unit type

SMF LD

Transmission distance

40

Interface type

SFP-LC

Wavelength (,range)

1261~1360

nm

Trise/Tfall (maximum; 20%~80%)

2.5

ns

RMS spectrum width (maximum)

nm

output optical power(maximum)

dBm

output optical power(minimum)

-5

dBm

Output optical power when the LD is


shut down(maximum)

-45

dBm

Extinction ratio (minimum)

10

dB

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

Unit
KM

35

ZXMP S385 V2.50 Product Description

Table 24

5.8.2

Receiver index of FE long distance optical interface

Item

10/125m SMF

Unit

Wavelength ( range)

1261~1360

Nm

Input optical power (maximum)

-9

dBm

Receiver sensitivity

-34

dBm

GE interface types and followed standard


GE interface index is show in Table 25 .
Table 25

GE interface index

Type

Rate(bps)

followed
standard

Interface type

interface

1000BASE-SX

1000M

IEEE 802.3z

M-1.8

SFP-LC

1000BASE-FX

1000M

IEEE 802.3z

S-1.1 or L-1.2

SFP-LC

All optical interface indices are described as following table.


1

GE MMF optical interface(M-1.8)


GE MMF optical interface(M-1.8) as show in Table 26 ,Table 27 .

Table 26

36

Transmission index of GE MMF optical interface

Item

62.5/125m MMF

Transmission unit type

MMF LD

Transmission distance

275

Interface

SFP-LC

Unit
m

Wavelength (, range)

830~860

nm

Trise/Tfall (maximum;10%~90%)

0.26

ns

RMS spectrum width(maximum)

0.85

nm

Output optical power(maximum)

-4

dBm

Output optical power(minimum)

-9.5

dBm

Output optical power when the LD is


shut down(maximum)

-35

dBm

RIN(maximum)

-117

dB/Hz

Extinction ratio(minimum)

dB

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 27

Receiver index of GE MMF optical interface

Item

62.5/125m MMF

Unit

Wavelength(,range)

770~860

nm

input optical power(maximum)

dBm

Receiver sensitivity

-17

dBm

Minimum return loss

12

dB

Intensified receiving sensitivity


(maximum)

-12.5

dBm

GE short distance SMF optical interface(S-1.1)


GE short distance SMF optical interface(S-1.1) as show in Table 28 ,Table 29 .

Table 28

Transmission index of GE short distance SMF optical interface

Item

10/125m SMF

Unit

Transmission unit type

SMF LD

Transmission distance

10

Interface type

SFP-LC

Wavelength(,range)

1270~1355

nm

Trise/Tfall (maximum;20%~80%)

0.26

ns

RMS spectrum width(maximum)

2.8

nm

KM

output optical power(maximum)

-3

dBm

output optical power(minimum)

-9.5

dBm

Output optical power when the LD is shut


down(maximum)

-35

dBm

Extinction ratio(minimum)

dB

RIN(maximum)

-120

dB/Hz

Table 29

Receiver index of GE short distance optical interface

Item

10/125m SMF

unit

Wavelength ( ,range)

1270~1355

nm

Input optical power (maximum)

-3

dBm

Receiver sensitivity

-20

dBm

Intensified receiving sensitivity


(maximum)

-14.4

dBm

GE long distance SMF optical interface(L-1.2)


GE long distance SMF optical interface(L-1.2)as show in Table 30 ,Table 31 .

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

37

ZXMP S385 V2.50 Product Description

Table 30

Item

10/125m SMF

Transmission unit type

SMF LD

Transmission distance

80

Interface type

SFP-LC

Wavelength (,range)

1540~1570

nm

Trise/Tfall (maximum;20%~80%)

2.5

ns

RMS spectrum width (maximum)

0.16

nm

output optical power(maximum)

dBm

output optical power(minimum)

dBm

Output optical power when the LD is shut


down(maximum)

-45

dBm

Extinction ratio(minimum)

dB

RIN(maximum)

-120

dB/Hz

Table 31

5.9

Transmission index of FE long distance SMF optical interface

Unit
Km

Receiver index of GE long distance optical interface

Item

10/125m SMF

Unit

Wavelength(,range)

1270~1600

nm

Input optical power(maximum)

dBm

Receiver sensitivity

-22

dBm

Intensified receiving sensitivity (maximum)

-14.5

dBm

Performance of OAD
OAD board consists of OADD and OADC.

OADD can add/drop 4 wavelengths of DWDM optical signals. These 4 wavelengths


are among C-band 40 wavelengths.

OADC can multiplex/demultiplex 4 wavelengths of CWDM optical signals and 1


channel
of
1310nm
optical
signal.
These
4
wavelengths
are
1471/1491/1511/1531nm or 1551/1571/1591/1611nm.

OADD/OADC can be upgraded. With board cascading, it can multiplex/demultiplex


8 wavelengths of optical signals.

OAD board may process the control commands from NM to make the online
upgrade of board software.

Performance of OADD and OADC are show in Table 32 ,Table 33 .

38

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 32

Performance of OADD

Item

Unit

Frequency Range

Min

Max

THz

192.1

196.0

Wavelength Range

nm

1529.55

1560.61

Channel Spacing

GHz

100

0.5 dB Passband

nm

0.11

20dB Passband

nm

1.20

In-drop

dB

2.5

3.3

Add-out

dB

2.5

3.3

In-out

dB

2.4

dB

1.0

Insertion Loss

Insertion Loss Uniformity

Table 33

Performance of OADC

Item

Unit

Channel Number

Parameter
6

Central wavelength

nm

1471/1491/1511/
1531

1471/1491/15
11/1531

1551/1571/15
91/1611

Passband @ 0.5dB

nm

6.5

6.5

6.5

Wavelength range of
upgrade port

nm

1544.5~1621

1544.5~1621

dB

0.5

0.5

0.5

@ 1310
Port

dB

0.7

Passband @ 1310 Port

nm

1260~1360

LnCWDM

dB

2.3

2.0

UPGCWDM

dB

1.7

Ln
UPG

dB

2.3

2.0

Ln 1310nm

dB

1.2

Ripple

Insertion
Loss
(Including
connectors)

5.10

Parameter

Performance of OBA
Performacen of OBA is show in Table 34 .

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

39

ZXMP S385 V2.50 Product Description

Table 34

Performance of OBA Module

Performance

Unit

OBA12

OBA14

OBA17

Operating wavelength

nm

1530~1565

1530~1565

1530~1565

Input power

dBm

-12~4

-12~4

-6~4

Output power(maximum)

dBm

12

14

17

Dynamic range of
output power (dB)

dB

Gain

dB

5~24

7~26

10~23

Small Signal Gain

dB

>25

>25

>25

Noise Index

dB

Input return loss

dB

45

45

45

output return loss

dB

45

45

45

Output pump leakage

dBm

-30

-30

-30

Input pump leakage

dBm

-30

-30

-30

PDG

dB

0.5

0.5

0.5

PMD

ps

Power(full temperature
range)

<25

<25

<25

-15~65

-15~65

-15~65

Operating temperature
Operating humidity

5~95

5~95

5~95

Storage temperature

-40~75

-40~75

-40~75

Optical Connector

LC/PC

LC/PC

LC/PC

Note:OBA19 Only operating at 155M and 622M bit rate.

5.11

Performance of OPA
Performance of OPA is show in Table 35 .
Table 35

40

Performance of OPA Module

Performance

unit

OPA38

OPA32

Operating wavelength

nm

1550.12

1550.12

Filter-3dB bandwidth

nm

0.45

0.45

Filter -20dB bandwidth

nm

1.2

1.2

Input power

dBm

-38~20

-32~15

Output power(maximum)

dBm

-9

-6

Dynamic range of output power (dB)

dB

Gain

dB

26~32

25~31

Small Signal Gain

dB

30

30

Noise Index

dB

4.5

4.5

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Performance

unit

OPA38

OPA32

Input return loss

dB

45

45

output return loss

dB

45

45

Output pump leakage

dBm

-30

-30

Input pump leakage

dBm

-50

-50

Forward ASE level

dBm

-30

-30

Backward ASE power level

dBm

-30

-30

Pump wavelength

nm

980

980

PDG

dB

0.2

0.2

PMD

ps

Power

15

15

Power supply

-4810%

-4810%

Operating temperature

-15~65

-15~65

5~95

5~95

Storage temperature

-40~75

-40~75

Optical Connector

LC/PC

LC/PC

Operating humidity

5.12

Performance of DCM
The Dispersion Compensating Modules compensates the dispersion of conventional
single mode fiber (G.652/G.655) Performance of the DCM is show in Table 36 .
Table 36

Performance of the DCM

Type

DCM-20

DCM-40

DCM-60

DCM-80

DCM-100

Dispersion
compensated
range(ps/nm)

-32915

-68021

102031

-136041

-164041

Insert loss(dB)

4.1

5.1

7.0

8.9

12.1
-11.5

typical value

-3.2

-4.4

-6

-7.7

PMD(2-step)

0.5

1.0

1.2

1.3

PMD(Typical)(ps)

-0.4

-0.4

-0.5

-0.6

0.1

0.1

0.1

PMD cost(dB)
Note:

Each DCM needs a 1U-high DCM-Box.;


Generally Only 10G system need to consider dispersion problem;
DCM80 can only be located in front of OBA and cannot be located after OPA

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

41

ZXMP S385 V2.50 Product Description

5.13

Error Performance
For each circuit direction and for bi-directional section and path, the error performance is
monitored separately, the SDH performance of ZXMP complies with ITU-T G.784, G.828
and G.826. The SDH performance includes performance items such as BBE, ES, SES,
FBBE, FEES, FESES, PSC, PJC+, PJC-, UAS, etc.
The long term and short-term error performances of ZXMP S385 are complied with ITUT G.828 and M.2101 recommendation. According to ITU-T G.821 and G.826, in 420km
HRDP (Hypothetical Reference Digital Path), SDH system error performance of ZTEs
transmission product is as follows, these figures are tested in field and test duration is
not less than 24 hour. SDH system error performance is show in Table 37 .
Table 37

SDH system error performance

Bit
rate(kbit/s)

2048

ESR

1.84810

SESR

9.2410

BBER

44736
-6

-8
-9

9.2410

155520
-6

3.46610

-8

9.2410

-9

9.2410

622080
-6

7.39210

-8

9.2410

-9

9.2410

2488320
-5

1.84810

-5

3.710

-8

9.2410

-9

9.2410

9.2410
9.2410

-8
-9

The performance is better than ITU-T recommendation.

5.14

Jitter index at interfaces


For ZXMP S385, the jitter and wander tolerance for G.703 PDH and SDH interface
conform to ITU-T G.823, G.824 (45Mbps) and G.825 respectively.

5.14.1

Jitter and wander tolerance of PDH input interface


The jitter and wander tolerance at ZXMP S385 PDH input interface meets the
requirements shown in Figure 10, Figure 11 and Table 38 ,Table 39 .

42

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Figure 10 The jitter and wander tolerance at E1 PDH input interface

Peak-peak jitter and wander


(logarithm)

A0
A3

Slope: -20dB/10 octave

A1
A2

f0

f10 f9

f8

f1

f2

f3

f4

Jitter frequency
(logarithm)

Figure 11 The jitter and wander tolerance at T1 PDH input interface

Table 38

The input jitter and wander tolerance of PDH interface

Interfa
ce rate

UIp-p

(kbit/s)

A0

A1

A2

1544

18

5.0
UI

0.
1U
I

2048

36.
9

18

0.
2

18

4.881
0-3

0.0
1

34368

618
.6

1.5

0.
15

ffs

ffs

ffs

44736

18

5.0
UI

0.
1U
I

Pseudo
random

Frequency (Hz)
A
3

f10(T1
/T3 is
f0)

f9

f8

f1

f2

f3

f4

signal

10

12
0

6k

40
K

220 1

1.6
67

20

2.4
k

18
k

10
0k

215-1

ffs

10
0

1k

10
k

80
0k

223-1

10

60
0

30
k

40
0k

220 1

1.210
5

1.2
105

Jitter and wander tolerance of PDH output interface

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

43

ZXMP S385 V2.50 Product Description

Table 39

The output jitter and wander tolerance of the PDH interface

Parameter
value

Digit rate
(kbit/s)

Network limit

Measurement filter bandwidth

B1 unit
interval

B2 unit
interval

Band-pass filter having a lower cutoff

peak-to-peak

peak-topeak

frequency f1 or f3 and an upper cutoff


frequency f4
f1

f3

f4

8kHz

40KHz

1 544

0.1

10Hz

2 048

1.5

0.2

20 Hz

34 368

1.5

0.15

100 Hz

10 kHz

800 kHz

44736

0.1

10Hz

30kHz

400kHz

18 kHz
(700 Hz)

100 kHz

Note:
For the co directional interface only.
The frequency values shown in parenthesis only apply to certain national interfaces.
UI Unit Interval: for 2048 Kbit/s 1 UI = 488 ns; for 34 368 Kbit/s 1 UI = 29.1 ns

5.14.2

Jitter and wander tolerance of SDH input interface


The capability of STM-N input interface to stand jitter and wander is specified and tested
with the digital test signal of sine modulated phase.
The input jitter and wander tolerance of ZXMP S385 SDH terminal multiplexer satisfies
the requirements in Figure 12, Table 40 and Table 41 .
The input jitter and wander tolerance of ZXMP S385 SDH regenerator satisfies the
requirements shown in Figure 13 and Table 42 .

44

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Figure 12 The jitter tolerance of STM-N terminal multiplexer input interface

Peak-peak jitter and wander (logarithm)


A0
A1

Slope: -20dB/10 octave


A2
A3
A4

f12

f0

Table 40

f11

f10

f9

f8

f1

f2

f3

f4

Frequency

Input jitter and wander tolerance (UIP-P) of SDH

STM
interface

A0 (18s)

A1 (2 s)

A2 (0.25 s)

A3

A4

STM-1

2800

311

39

1.5

0.15

STM-4

11200

1244

156

1.5

0.15

STM-16

44790

4977

622

1.5

0.15

Table 41

Input jitter and wander tolerance of the SDH

STM
interface

f0

f12

f11

f10

f9

f8

f1

f2

f3

f4

STM-1

1.2
10-5

1.78
10-4

1.6
10-3

1.56
10-2

0.125

19.3

500

6.5k

65k

1.3M

STM-4

1.2
10-5

1.78
10-4

1.6
10-3

1.56
10-2

0.125

9.65

1000

25k

250k

5M

STM-16

1.2
10-5

1.78
10-4

1.6
10-3

1.56
10-2

0.125

12.1

5000

100k

1M

20M

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

45

ZXMP S385 V2.50 Product Description

Figure 13 The input jitter tolerance of STM-N SDH regenerator

Input jitter amplitude

UI

P-P

A2
Slope: -20dB/10 octave

A1

Table 42

f1

Frequency

Input jitter tolerances of STM-N regenerators

STM interface
STM-1
STM-4
STM-16

5.14.3

f2

f1 (kHz)

f2 (kHz)

A1 (UIP-P)

A2 (UIP-P)

65

6.5

0.15

1.5

12

1.2

0.15

1.5

250

25

0.15

1.5

12

1.2

0.15

1.5

1000

100

0.15

1.5

12

1.2

0.15

1.5

Inherent output jitter of STM-N interface


For the ADM, TM and DXC equipment of ZXMP S385, the STM-N output jittering
indexes meet the requirements in Table 43 and Table 44 .
Because of the randomness of jitter, the test value might exceed, and it is acceptable
when over 99% test values satisfy the indexes during the test (for 1 to 2 minutes).
Table 43

STM-N interface inherent output jitter indexes of SDH

STM interface
STM-1
STM-4
STM-16

46

Test filter

Peak value of jitter

500Hz~1.3MHz

0.50 UI

65kHz~1.3MHz

0.10 UI

1000Hz~5MHz

0.50 UI

250kHz~5MHz

0.10 UI

5000Hz~20MHz

0.50 UI

1MHz~20MHz

0.10 UI

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 44

STM-N network interface output jitter indexes of SDH

STM interface

f1 (Hz)

f3 (kHz)

f4 (MHz)

B1 (UIp-p)

B2 (UIp-p)

STM-1 optical
interface

500

65

1.3

1.5

0.15

STM-1 electrical
interface

500

65

1.3

1.5

0.075

STM-4 optical
interface

1000

250

1.5

0.15

STM-16 optical
interface

5000

1M

20

1.5

0.15

For the REG equipment, when the test filter adopts 12 kHz high-pass filter, its root mean
square value (RMS) created from jitter should not be greater than 0.01UIrms.

5.14.4

Mapping jitter of PDH tributary


The mapping jitter at the ZXMP S385 PDH tributary can satisfy the requirements listed in
Table 45 .
Table 45

Mapping jitter specifications

G.703
interface

Tolerance
(ppm)

(kbit/s)

5.14.5

High-pass filter 20dB/10


multiplication

Maximum peak value


of mapping jitter

f1 (Hz)

f3 (Hz)

f4 (Hz)

f1~f4

f3~f4

2048

50

20

18k

100k

Undetermined

0.08

34368

20

100

10k

800k

Undetermined

0.08

44736

20

100

10k

800k

Undetermined

0.08

Combined Jitter
In the SDH system, generally, there are both mapping jitter and pointer adjusting jitter.
The combined jitter of both is called the combined jitter. Under various test sequences,
the value detected by ZXMP S385 should meet the ones listed in Table 46 .
Table 46

Combined jitter

PDH
inter
face

Bit
rate
toler
ance

High pass filter


20dB/10 octave

(kbit/
s)

(ppm
)

f1
(Hz)

f3
(Hz)

f4
(Hz)

f1~f4 (UIp-p)

f3~f4 (UIp-p)

2048

50

20

18k

100
k

0.4

0.4

0.4

0.0
75

0.0
75

0.0
75

3436
8

30

100

10k

800
k

0.4

0.4

0.4

0.0
75

0.0
75

0.0
75

ZTE Confidential Proprietary

Maximum peak-peak value combined


jitter UIP-P

0.
75

2009 ZTE Corporation. All rights reserved.

47

0.0
75

ZXMP S385 V2.50 Product Description

PDH
inter
face

Bit
rate
toler
ance

High pass filter


20dB/10 octave

4473
6

30

100

10k

Maximum peak-peak value combined


jitter UIP-P
800
k

Test sequence

5.14.6

0.4

0.4

0.4

0.
75

0.0
75

0.0
75

0.0
75

0.0
75

Jitter transfer function of the regeneration relay


The jitter transfer function of the regeneration relay is defined the ratio of output STM-N
signal jitter to the input STM-N signal jitter versus frequency.
The jitter transmission characteristic of ZXMP S385 SDH regeneration relay is shown in
Figure 14.
Figure 14 The jitter transfer characteristics of a regeneration relay

Input jitter amplitude

(UI P-P )
A2
Slope: -20dB/10 octave

A1

f2

f1

Frequency

The jitter transmission parameters of regeneration relay are shown in Table 47 .


Table 47

Jitter transmission parameters of a regeneration relay

STM-N
A

STM-1
STM-4
STM-16

5.15

fc (kHz)

P (dB)

130

0.1

30

0.1

500

0.1

30

0.1

2000

0.1

30

0.1

Clock timing and synchronous characteristics

48

The SEC Index list is show in Table 48 .

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 48

The SEC Index list

Vendor

ISOTEMP

Type

OCXO

Standard Central Frequency

77.76MHz

Day aging rate

110-8

Year aging rate

510-7

Central frequency precision

110-7(0V)

Short time stability

110-10/s

Temperature characteristic

510-8(0~50C)

Output jitter
When there is no input jitter, the inhered jitter of ZXMP S385 2M clock output
interface should not be over 0.05 UIP-P. The test is conducted at an interval of
every 60 seconds with a single-pole band-pass filter in 20Hz and 100kHz turnover
frequencies.

Permitted input/output attenuation and others


For ZXMP S385 the bit rate tolerance of clock output signal is 4.6ppm.

Long-term phase variation in clock locking mode


The long-term phase variation in the clock locking mode refers to the phase noise
generated at the SEC output terminal when there is an ideal input reference signal.
Usually, they are expressed by the Maximum Time Interval Error (MTIE) and time
deviation error (MTIE). ZXMP S385 can satisfy the requirements shown in Table 49
Table 50 and Table 51 .

Table 49

The wander limit value under constant temperature (MTIE)

MTIE limits

Observation interval

40 ns

0.1s 1s

40 0.1 ns

1s 100s

25.25 0.2 ns

100s 1000s

Table 50

The wander limit value under temperature impact (MTIE)

Additional MTIE permitted value

Observation interval

0.5ns

0.1s

50ns

118s

Table 51

100s

The wander limit value under constant temperature (TDEV)

MTIE limits

Observation interval

3.2 ns

0.1s

ZTE Confidential Proprietary

25s

2009 ZTE Corporation. All rights reserved.

49

ZXMP S385 V2.50 Product Description

MTIE limits
0.64
6.4 ns

0.5 ns

Observation interval
25s
100s

100s
1000s

Clock accuracy in the hold mode


Once all the timing references are lost, SEC will enter the hold mode after
instantaneous phase variation. Now, SEC will use the last frequency information
saved before the timing reference signal loss as its timing reference. Meanwhile, the
oscillation frequency of the oscillator will slowly wander, but can still ensure that
SEC frequency only has very small frequency deviation from the reference
frequency in a long time base; therefore, the sliding loss will be within the allowed
index requirement. This mode can be used to deal with an external clock failure
lasting several days.
When SEC loses its reference source and enters the hold mode, the phase error T
of the SEC output signal to the input signal should not be over the following limits
when observation time S is greater than 15s from the moment that the reference
source loses.
T (S) = [(a1+a2)S+0.5bS2+c] ns
a1= 50ns/s corresponds to the initial frequency deviation of 510-8.
a2=2000ns/s refers to the frequency deviation caused by the temperature change
after the clock enters the hold mode. If there is no temperature change in 2 10-6,
there will be no a2S in the phase error.
b = 1.1610-4ns/s. It is caused by aging, corresponding to 110-8/day frequency
wander.
c = 120ns, includes any additional phase deviation that might be generated after
entering the transition stage of hold mode.
ZXMP S385 meets the above requirements.

Frequency Accuracy of Internal Oscillator in the Free-run Mode


When the internal oscillator of SEC works in the free-run mode if SEC loses all of
the clock references, and their memories or SEC has no hold mode at all, it is
required that its output frequency accuracy be within a certain range.

For a reference that can follow the G.811 clock, the SEC output frequency accuracy in
the free-run mode should not be greater than 4.6ppm for SDH terminal equipment and
20ppm for REG equipment. ZXMP S385 can satisfy the above requirements.

50

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Environment Adaptability

6.1

Power supply requirements


Working voltage and current:

6.2

Rated working voltage: -48V

Rated working current: 16A

Nominal voltage: -48VDC

Range: -57VDC~-40VDC

Grounding requirements
If separate grounding is adopted in the equipment room, the grounding resistance
should meet the following requirements:

The grounding resistance in case of 48V DC is less than or equal to 4.

The grounding resistance for the system working ground is less than or equal to 4.

The grounding resistance for the lightning protection ground is less than or equal to
4.

If the combined grounding is adopted in the user equipment room, the grounding
resistance should be less than or equal to 1.
The voltage difference among lightning protection ground, system working ground and 48V GND should be less than 1V.
The tandem requirements between all groundings are as follows:

The -48V ground of the board is isolated from the -48V GND.

The board shielding plate is connected to the cabinet via the front panel, and there
is an electrical connection with the co-module filter capacitor inside a board.

The lightening protection GND only connects to the protection component, and
converges with the system working GND at the grounding terminal on the bus bar of the
rack. The -48V GND can converge with the PGND, or the combined GND on the bus bar
of the rack, or be grounded outside.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

51

ZXMP S385 V2.50 Product Description

6.3

Environment requirements

6.3.1

Operation Environment
1

Climate
Climate requirement is show in Table 52 .

Table 52

Climate requirement

Item

Range

Altitude

4000m

Air pressure

70 ~ 106kPa

Temperature (Long-term Operating)

+5 ~+40

Temperature (Short-term Operating)

0 ~+45

Temperature change rate

0.5

Relative humidity (Short-term Operating)

20%~80%

Relative humidity (Long-term Operating)

10%~90%

Heat radiation

300W/s

/min

In the normal working environment, the measuring point of the temperature and
humidity refers to data obtained at the place 1.5 meters above the floor and 0.4m
meters in front of the equipment. The short-term working refers to working
continuously for no more than 48 hours and no more than accumulated 15 days in a
year.
2

Biological environment
Avoid multiplication of microbe, such as eumycete and mycete.
Avoid the rodent, e.g., mice.

Air cleanliness
Density requirements for chemical active substances is show in Table 53

Table 53

Density requirements for chemical active substances

Chemical active substance

52

Content
mean (mg/m)

Max( mg/m)

SO2

0.3

H2S

0.1

0.5

NH3

Cl2

0.1

0.3

HCl

0.1

0.5

HF

0.01

0.03

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Content

Chemical active substance

mean (mg/m)

Max( mg/m)

O3

0.05

0.1

NO2

0.5

Density requirements for mechanical active substances is show in Table 54 .


Table 54

Density requirements for mechanical active substances

Mechanical active substance

Content

Perceivable dust

= 15 mg/mh

Mechanical stress
Requirements for mechanical stress is show in Table 55 .

Table 55

Requirements for mechanical stress

Item

Unit

Value

Acceleration

m/S2

0.1

Frequency range

Hz

5~100, 100~5

direction

X,Y,Z

duration

Min

90

Condition of earthquake
According with:NEBS GR-63
IEC721-2-6 Environmental conditions appearing in nature-Earthquake vibration
IEC68-3-3 Environmental testing - Part 3: Background information - Subpart 3:
Guidance. Seismic test methods for equipment

6.3.2

Environment for Storage


The following Table 56 ,Table 57 international standards are taken as the reference for
framing the environment requirements:
IEC721-3-1 Classes 1K4/1Z2/1Z3/1Z5/1B2/1C2/1S3/1M2
1

Climate

Table 56

Climate requirement

Item

Range

Altitude

4000m

Air pressure

70 ~ 106kPa

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

53

ZXMP S385 V2.50 Product Description

Item

Range

Temperature

-40 ~ +70

Temperature change rate

0.5C/min

Relative humidity

10% ~ 100%

Solar radiation

600W/s

Air speed

30m/s

Mechanical stress

Table 57

Requirements for mechanical stress

Item

unit

value

Acceleration

m/S2

0.1

Frequency range

Hz

5~100, 100~5

direction

X,Y,Z

duration

Min

90

The earthquake-proof performance of the whole equipment complies with Earthquakeproof Performance Detection for SDH Optical Communications Equipment (Provisional)
and Earthquake-proof Performance Detection for SDH Optical Communications
Equipment (Provisional). The earthquake-proof performance detection reaches the
eight-level intensity.

6.3.3

Cleanness requirements
Cleanness involves dust and harmful gases in the air. The equipment should be
operated in the equipment room that meets the cleanness requirements described below:

6.3.4

In the transmission equipment room, there is no explosive, electrically conductive,


magnetically conductive or corrosive dust.

The density of dust particles with the diameter greater than 5m should be no more
than 3104 particles/m3.

No corrosive metal or gases that are detrimental to the insulation exist in the
equipment room, such as SO2 and NH3.

The equipment room should be always kept clean, with doors and windows being
closed.

Bearing Requirements of the Equipment Room


The bearing capability of the equipment room should be over 450kg/m2 to hold ZXMP
S385 equipment.
Electromagnetic Compatibility (EMC) requirements

54

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Before introducing the EMC requirements, firstly specifies 3 criteria for test results:

6.3.5

Performance A: Continuous phenomenon. Neither error nor alarm is allowed. After


the electromagnetic interference, the number of errors shall not exceed the
maximum of the normal requirement.

Performance B: Transient phenomenon. During the electromagnetic interference,


the degradation of function is allowed, the equipment can work as expected without
the operators interference, the loss of frame and synchronization is not allowed,
and neither pattern out-of-sync, nor AIS alarm is generated. The equipment shall
work normally after the electromagnetic interference.

Performance R: Resistive phenomenon. The fuse or other special devices can be


replaced or restarted.

Electronic Static Discharge (ESD)


1

Anti-interference for static discharging


The static discharge anti-interference index of ZXMP S385 equipment is shown in
Table 58 . During the operation in the interface area, be sure to wear an antistatic
wrist strap.

Table 58

Static discharge anti-interference

Contact discharge

Air discharge

Criterion for test results

6kV

8kV

Performance B

8kV

15kV

Performance R

RF electromagnetic radiated susceptibility


The RF electromagnetic radiated susceptibility of ZXMP S385 equipment is shown
in Table 59 .

Table 59

RF electromagnetic radiated susceptibility

Test frequency (80MHz~1000MHz)


Electric field intensity

Amplitude modulation

Criterion for test results

10V/m

80%AM (1kHz)

Performance A

Electrical fast transient burst susceptibility


The electrical fast transient burst susceptibility of ZXMP S385 equipment is shown
in Table 60 and Table 61 .

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

55

ZXMP S385 V2.50 Product Description

Table 60

Electrical fast transient burst susceptibility at the DC power port

Generator waveform 5/50ns


Test voltage

Repeated frequency

Criterion for test results

1kV

5kHz

Performance B

Table 61

Electrical fast transient burst susceptibilities at the signal cable and control cable ports

Generator waveform 5/50ns


Test voltage

Repeated frequency

Criterion for test results

1kV

5kHz

Performance B

Surge susceptibility
The surge susceptibility of ZXMP S385 equipment is shown in Table 62 , Table 63
and Table 64 .

Table 62

Surge susceptibility of DC power

The waveform of generators 1.2/50us (8/20s), internal resistance 12


Test mode

Test voltage

Criterion for test results

Line to ground

1kV

Performance B

Line to ground

2kV

Performance R

Table 63

Surge susceptibility of the outdoor signal cable

The waveform of generators 10/700s, internal resistance 40


Test mode
Line to line
Line to ground
Line to line
Line to ground

Table 64

Test voltage

Criterion for test results

2kV

Performance B

4kV

Performance R

Surge susceptibility of the indoor signal cable

Generator waveform 1.2/50s (8/20s), internal resistance 42


Test mode

Test voltage

Criterion for test results

Line to ground

1kV

Performance B

Line to ground

2kV

Performance R

Conductivity susceptibility of RF field


The conductivity susceptibility of RF field of ZXMP S385 equipment is shown in
Table 65 .

56

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Table 65

Conductivity susceptibility of RF field

Test frequency 0.15MHz ~ 80MHz


Test intensity

Amplitude modulation

Criterion for test results

3V

80%AM (1kHz)

Performance A

Electromagnetic Interference (EMI)


6

Conductive emission electromagnetic interference


The conductive emission electromagnetic interference of ZXMP S385 equipment is
shown in Table 66 .

Table 66

Conductive emission electromagnetic interference at the direct current port

Limits (dBuV)

Testing frequency (MHz)

Quasi-peak

Mean value

0.02~0.15

79

--

0.15~0.5

79

66

0.5~30

73

60

Radioactive emission electromagnetic interference


The radioactive emission electromagnetic interference of the ZXMP S385
equipment is shown in Table 67 .

Table 67

Radioactive emission electromagnetic interference

Testing frequency (MHz)

6.4

Quasi-peak demodulating limit (dBV/m)


10m

3m

30~230

40

50

230~1000

47

57

230~1000

47

57

Safety requirements
This product adopts the technical requirements specified in the following standard:

IEC/EN 60950:2000 Safety of information technology equipment

Working voltage and current


Rated working voltage: -48V
Max. working voltage: -57V
Min. working voltage: -40V

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

57

ZXMP S385 V2.50 Product Description

Rated working current: 16A

Insulation classification of the equipment


The power supply of the equipment provides the SELV circuit with safe and
excessively low voltage, without self-generating dangerous voltage. It belongs to the
equipment of the class III insulation (Class III equipment).

Optical interface
The optical module of the maximum power belongs to (Class 3A). All the optical
modules shall be under strict control and certified by authorities (such as UL, TUV
and NEMKO), and comply with EN60825.

Fuse
All the fuses and power modules, including recoverable fuses, shall be certified by
authorities such as CE, UL and TUV.

Safety mark
On the package of the equipment, there are striking labels about antistatic, fragile,
waterproof, and damp-proof.
The maximum optical power satisfies the 3A safety standard. An obvious label
warning against the laser shall be pasted at the optical interface.
Cables of different colors shall be used for the power input, shielding GND and
lightening protection GND to avoid incorrect connection. Different power connectors
shall use coding keys. There shall be a power label at the power inlet.
Both the equipment and each board shall have an antistatic label.
Grounding symbol

indicates switch-on, and

indicates switch-off.

Mechanical structure
In installation, four bolts are designed at the rack bottom (may also be used to
adjust balance) to fix the rack to the ground. At the rack top, the corresponding
screws are designed to fix the rack to the cabling rack. When installed in the
equipment room, the rack shall be fixed both at the top and bottom to ensure the
stability and safety of the equipment.
The corners of both the rack and sub-rack are processed to avoid hurting people.

Fire protection
The materials of the circuit boards in the equipment use the fireproof materials of
the V-2 level to prevent the circuits from burning in case of failure.
The structural parts use unburnable materials with a good fireproof performance,
including surface processing materials.

58

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

With the effective heat dissipation design, it ensures that the temperature does not
exceed 70C to prevent heat aggregation and reduce the possibility of burning.
Safe parts passing the safety authentication (CE, UL, etc.) are used.

High temperature protection


In abnormal conditions, the temperature does not exceed 70C. The plastic parts,
components, wires and cables, and safety labels shall all comply with the
requirements specified in the safety standard-GB4943/EN60950.

Lightening protection
In this system, good grounding and isolation and protection of electrical interfaces
are used to prevent the dangerous voltage of lightening.

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

59

ZXMP S385 V2.50 Product Description

Glossary
Abbreviations

60

Full Name

ADM

Add-Drop Multiplexer

AFEC

Advanced Forward Error Correction

AIS

Alarm Indication Signal

ANSI

American National Standards Institute

APS

Automatic Protection Switching

ASIC

Application Specific Integrated Circuit

ASON

Automatically Switched Optical Network

ATM

Asynchronous Transfer Mode

AU

Administrative Unit

AUG

Administration Unit Group

AU-n

Administration Unit, level n

AU-PTR

Administration Unit Pointer

BBE

Background Block Error

BBER

Background Block Error Ratio

BER

Bit Error Ratio

BITS

Building Integrated Timing Supply

BML

Business Management Layer

CBR

Constant Bit Rate

CDM

Code Division Multiplexing

CLP

Cell Loss Priority

CMI

Coded Mark Inversion

C-n

Container- n

CORBA

Common Object Request Broker


Architecture

CV

Code Violation

CWDM

Coarse Wavelength Division Multiplexing

DB

Data Base

DBMS

Data Base Management System

DCC

Data Communications Channel

DCE

Data Circuit-terminating Equipment

DCF

Data Communications Function

DCN

Data Communications Network

DDN

Digital Data Network

DLL

Dynamic Link Libraries

DNA

Distributed Network Architecture

DNI

Dual Node Interconnection

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Abbreviations

Full Name

DQDB

Distributed Queue Double Bus

DTE

Data Terminal Equipment

DWDM

Dense Wavelength-division Multiplexing

DXC

Digital Cross Connect

ECC

Embedded Control Channel

EDFA

Erbium Doped Fiber Amplifier

EM

Element Management

EMC

Electromagnetic Compatibility

EMI

Electromagnetic Interference

EML

Element Management Layer

EMS

Element Management System

EOS

Ethernet Over SDH

ES

Error Second

ESD

Electronic Static Discharge

ESR

Error Second Ratio

ETS

European Telecommunication Standards

ETSI

European Telecommunication Standards


Institute

FDDI

Fiber Distributed Data Interface

FDM

Frequency Division Multiplexing

FE

Fast Ethernet

FEBBE

Far End Background Block Error

FEC

Forward Error Correction

FEES

Far End Error Second

FESES

Far End Severely Error Second

GUI

Graphical User Interface

HDLC

High Digital Link Control

HPC

Higher order Path Connection

HW

High-Way

IEC

International Electro technical


Commission

IEEE

Institute of Electrical & Electronic


Engineers

IP

Internet Protocol

ITU-T

International Telecommunication UnionTelecommunication Standardization


Sector

L2

Layer 2

LAN

Local Area Network

LAPD

Link Access Procedure On D-channel

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

61

ZXMP S385 V2.50 Product Description

62

Abbreviations

Full Name

LAPS

Link Access Procedure for SDH

LCD

Loss of ATM Cell Delineation

LCT

Local Craft Terminal

LOF

Loss Of Frame

LOP

Loss Of Pointer

LOS

Loss Of Signal

LPC

Lower order Path Connection

MAC

Medium Access Control

MAN

Metropolitan Area Network

MCF

Message Communication Function

MCU

Micro Control Unit

MD

Mediation Device

MF

Mediation Function

MII

Medium Independent Interface

MM

Multi Mode

MS

Multiplex Section

MS-AIS

Multiplex Sections - Alarm Indication


Signal

MSOH

Multiplex Section OverHead

MSP

Multiplex Section Protection

MS-PSC

Multiplex Sections - Protection Switching


Count

MS-PSD

Multiplex Sections - Protection Switching


Duration

MS-SPRing

Multiplexer Section Shared Protection


Ring

MST

Multiplex Section Terminal

MTIE

Maximum Time Interval Error

NE

Network Element

NEF

Network Element Function

NEL

Network Element Layer

NML

Network Manager Layer

NMS

Network Management System

NRZ

Non-Return-to-Zero

OAM

Operation, Administration and


Maintenance

OFS

Out of Frame Second

OOF

Out of Frame

OS

Operation System

OSF

Operation System Function

2011 ZTE Corporation. All rights reserved.

ZTE Confidential Proprietary

ZXMP S385 V2.50 Product Description

Abbreviations

Full Name

OSI

Open System Interconnect

PCB

Printed Circuit Board

PCM

Pulse Code Modulation

PDH

Plesiochronous Digital Hierarchy

PGND

Protection GND

PHY

physical Layer Device

PJE-

Pointer Justification Event -

PJE+

Pointer Justification Event +

POH

Path OverHead

PPP

Point to Point Protocol

PRC

Primary Reference Clock

QA

Q Adaptor

QAF

Q Adaptor Function

QoS

Quality of Service

RAM

Random Access Memory

RDI

Remote Defect Indication

REG

Regenerator

REI

Remote Error Indication

RFI

Remote Failure Indication

RIP

Router Information Protocol

RMII

Reduced Medium Independent Interface

RS

Regenerator Section

RSOH

Regenerator Section OverHead

SAR

Segmentation and Reassembly

SDH

Synchronous Digital Hierarchy

SEC

SDH Equipment Clock

SEMF

Synchronous Equipment Manage


Function

SES

Severely Error Second

SESR

Severely Error Second Ratio

SETS

Synchronous Equipment Timing Source

SM

Single Mode

SMCC

Sub-network management control center

SML

Service Management Layer

SMN

SDH Management Network

SMS

SDH Management Sub-Network

SMT

Surface Mount Technology

SNC

Sub-network Connection

SNCP

Sub-network Connection Protection

ZTE Confidential Proprietary

2009 ZTE Corporation. All rights reserved.

63

ZXMP S385 V2.50 Product Description

64

Abbreviations

Full Name

SOH

Section Overhead

SPRING

Shared Protection Ring

SSF

Service Signal Fail

SSM

Synchronization status messaging

SSM

Synchronous State Message

STM-N

Synchronous Transport Module Level-N

TCP

Transport Control Protocol

TDEV

Time Deviation

TDM

Time Division Multiplex

TM

Terminal Multiplexer

TMN

Telecommunications Management
Network

TTL

Transistor-Transistor Logic

TU

Tributary Unit

TUG-m

Tributary Unit Group, level m

TU-m

Tributary Unit, level m

UART

Universal Asynchronous Receiver


Transmitter

UAS

Unavailable Second

UBR

Unspecified Bit Rate

UNI

User-Network Interface

UPC

Usage Parameter Control

VBR

Variable Bit Rate

VC

Virtual Channel

VC

Virtual Container

VCI

Virtual channel Indicator

VC-n

Virtual Container, level n

VDN

Virtual Data Network

VLAN

Virtual Local Area Network

VP

Virtual Path

VPI

Virtual Path Indicator

VPG

VP Group

WAN

Wide Area Network

WDM

Wavelength Division Multiplexing

WS

Work Station

WSF

Work Station Function

ZXMP

Zhong Xing MSTP

2011 ZTE Corporation. All rights reserved.