Professional Documents
Culture Documents
Date
Author
Approved By
Remarks
R0
2009-09-20
ZhangQiSheng
WangQiang,QinYong
R1
2010-05-20
LiXiongFei
WangQiang,QinYong
TABLE OF CONTENTS
1
Overview ................................................................................................................... 1
2
2.1
2.2
2.3
2.4
2.5
2.6
Features .................................................................................................................... 2
Flexible networking & dispatching function raises profit-making ability and reduces
CAPEX ...................................................................................................................... 2
Superior scalability protects CAPEX and reduces OPEX .......................................... 2
Leading RPR function supports IP evolution and protects CAPEX ............................ 2
Powerful embedded WDM function saves fiber resource .......................................... 2
Flexible design facilitates network planning & optimization........................................ 2
Wide application, mature technology and high reliability............................................ 2
3
3.1
3.2
3.2.1
3.2.2
3.2.3
3.3
3.4
3.5
3.6
3.7
3.8
3.9
3.10
3.11
3.12
Functions.................................................................................................................. 4
Cross-connection and extension capabilities ............................................................. 4
Powerful Service Access Ability................................................................................. 4
Optical Interfaces ...................................................................................................... 4
Electrical Interfaces ................................................................................................... 5
Data Interfaces .......................................................................................................... 5
Integrated WDM Function .......................................................................................... 6
Complete Equipment Protection Ability...................................................................... 6
Perfect Network Protection Ability ............................................................................. 7
Reliable Timing Synchronization Processing ............................................................. 7
System control and communication ........................................................................... 8
Overhead Processing ................................................................................................ 8
Easy For Maintenance And Upgrade ....................................................................... 10
Alarm input/output ................................................................................................... 10
System power supply .............................................................................................. 10
Perfect EMC and Operation Safety ......................................................................... 11
4
4.1
4.1.1
4.1.2
4.2
4.3
5
5.1
5.1.1
5.1.2
5.1.3
5.2
5.3
5.4
5.5
5.6
5.7
5.7.1
5.7.2
5.7.3
5.7.4
5.7.5
5.8
II
5.8.1
5.8.2
5.9
5.10
5.11
5.12
5.13
5.14
5.14.1
5.14.2
5.14.3
5.14.4
5.14.5
5.14.6
5.15
6
6.1
6.2
6.3
6.3.1
6.3.2
6.3.3
6.3.4
6.3.5
6.4
Environment Adaptability...................................................................................... 51
Power supply requirements ..................................................................................... 51
Grounding requirements .......................................................................................... 51
Environment requirements ...................................................................................... 52
Operation Environment ............................................................................................ 52
Environment for Storage .......................................................................................... 53
Cleanness requirements .......................................................................................... 54
Bearing Requirements of the Equipment Room....................................................... 54
Electronic Static Discharge (ESD) ........................................................................... 55
Safety requirements ................................................................................................ 57
Glossary ................................................................................................................. 60
III
FIGURES
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
TABLES
Table 1
Table 2
Table 3
Table 4
Table 5
Table 6
Table 7
Table 8
Table 9
Table 10
Table 11
Table 12
Table 13
Table 14
Table 15
Table 16
Table 17
Table 18
Table 19
Table 20
Table 21
Table 22
Table 23
Table 24
IV
Table 25
Table 26
Table 27
Table 28
Table 29
Table 30
Table 31
Table 32
Table 33
Table 34
Table 35
Table 36
Table 37
Table 38
Table 39
Table 40
Table 41
Table 42
Table 43
Table 44
Table 45
Table 46
Table 47
Table 48
Table 49
Table 50
Table 51
Table 52
Table 53
Table 54
Table 55
Table 56
Table 57
Table 58
Table 59
Table 60
Table 61
Table 62
Table 63
Table 64
Table 65
Table 66
Table 67
Overview
ZXMP S385 is an optical transmission platform newly released by ZTE. ZXMP S385
targets the backbone or large capacity convergent layer of network which can satisfy
present and future network requirements. It is an ideal transmission system in
constructing broadband transmission networks.
ZXMP S385 provides rich service access functions and complete protection mechanism,
facilitating its wide applications.
ZXMP S385 adopts modular design, incorporating SDH, Ethernet, ATM, PDH and other
technologies. It can transmit voice and data services efficiently on the same platform.
This document is based on ZXMP S385 V2.50.
Features
2.1
2.2
2.3
2.4
2.5
2.6
Due to mature technology and superior performance, ZXMP S385 is widely deployed in
major carriers and private networks as well as other countries and regions, e.g., Korea,
Pakistan, Morocco and Vietnam.
Functions
3.1
3.2
3.2.1
Optical Interfaces
ZXMP S385 provides five types of optical interfaces: OTU2, STM-64, STM-16, STM-4
and STM-1, as shown in Table 1 .
Table 1
Board Type
Rate (Mbit/s)
Board Integration
(channel/board)
OTU2
10709.225
14
STM-64
9953.280
1/2
14/28
STM-16
2488.320
4/8
56/72
STM-4
622.080
1/2/4
56
STM-1
155.520
2/4/8/16
208
ZXMP S385 has the one-interface OTU2 optical line board to support AFEC or G.709
standard FEC function. By increasing the line rate, the board can correct the bit errors in
the line transmission. It may increase the receiving sensitivity by about 2dB or the OSNR
tolerance by 5-7dB, and work with OBA+OPA and Dispersion Compensation Module
(DCM) to implement the LH transmission without electrical regeneration.
ZXMP S385 also provides OTU2/STM-64/STM-16 colored interfaces comply with ITU-T
G.692 and ITU-T G.695, which can be connected to DWDM/CWDM directly without the
OTU board.
ZXMP S385 provides OTU2/STM-64/STM-16 DWDM wavelength interface with ITU-T
standard 50GHz grid in C-band.
3.2.2
Electrical Interfaces
ZXMP S385 provides STM-1 electrical interface and PDH electrical interfaces, as listed
in Table 2
Table 2
3.2.3
Board Type
Rate (Mbit/s)
Board Integration
(channel/board)
STM-1
155.520
4/8/16
208
E3
34.368
96
T3
44.736
96
E1
2.048
63
1260
T1
1.544
63
1260
Data Interfaces
There are several data boards in ZXMP S385 V2.50:SEE,TGE2B, RSEB, AP18 and
TGSA8, as shown in Table 3 .
SEE board provide 810M/100M+2GE Ethernet services which support L2 switching
function and EPS protection function.
TGE2B board provides 2GE adaptive Ethernet services.
3.3
Board
Integration
(channel/board)
Maximum Access
Capacity
SEE
810M/100 M +2GE
8+2
128+32
TGE2B
2GE
56
RSEB
810M/100 M +2GE
8+2
128+32
AP18
8155 Mbit/s
112
TGSA8
(4SAN+4GE) or 8GE
(4+4) or 8
(56+56) or 112
3.4
Table 4
Items protected
Protection scheme
FE board
CSF/CSE/CSA(Cross-switch
and Synchronous-clock board)
NCP/ENCP board
3.5
3.6
Providing system clock signals and system frame header signals for all the units of
the SDH equipment.
SCI board of ZXMP S385 provides four external reference clock output and four external
reference clock input. The interface type is 2Mbit/s or 2MHz.
SCI can be configured with four external 2.048M clock input references and 28 lines (or
tributary) 8K timing input references. Synchronization can select external clocks, line
clocks or E1/T1 tributary clocks.
The protection switching of clock reference sources bases on the alarm information and
clock synchronization status message (SSM) algorithm-based automatic switching.
ZXMP S385 provides E1 tributary re-timing function. It supports synchronous priority
switching based on the SSM algorithm, optimizes synchronous timing distribution of the
network, prevents the occurrence of timing loops and keeps network synchronization the
optimal status.
A software-controlled or a hardware phase lock circuit is used to implement four working
modes: a. Fast pull-in; b. Locked; c. Holdover; d. Free run.
3.7
3.8
Overhead Processing
The overhead process of ZXMP S385 is performed by NCP/ENCP board, OW board,
CSF/CSE/CSA board, optical line boards and ATM board.
ZXMP S385 supports overhead transparent transmission, i.e. low rate service signal and
overhead can transfer transparently in STM-16 frame. It greatly improves the network
construction flexibility, abates the tension of insufficient optical fiber resources, and
ensures the NM integrity and the NM information continuity.Overhead-Byte Usage List is
show in Table 5 .
Table 5
Overhead
type
Overhead
name
A1, A2
J0
Z0
Not applied
D1~D12
E1, E2
F1
B1
B2
K1, K2
S1
M1
AU PTR
J1
B3
C2
G1
F2, F3
Not applying
H4
K3
Not applied
N1
Not applied
V5
J2
N2
Not supported
RSOH/MSOH
AU pointer
POH
Overhead
type
3.9
Overhead
name
K4
3.10
It supports online loading and remote upgrading of card software (including FPGA
logic).
It provides the daily maintenance function. In case of a fault, it can quickly locate the
fault to the card level.
Alarm input/output
NCP/ENCP provides 8 external alarm Boolean value input interfaces and two control
output interface.
NCP/ENCP collects alarm indication signals from NEs and sends them to the alarm box
and the first cabinet of the line. There are four alarm output interfaces.
The system provides two user alarm output interfaces and level alarms. It shares a DB9
interface with F1 interface at the backplane side.
3.11
10
3.12
11
System Architecture
4.1
4.1.1
System architecture
ZXMP S385 functional block diagram is shown in Error! Reference source not found.
Figure 1
SDH Equipment
(TM, ADM, REG)
ZXONM E300
EMS/SNMS
Security management
Maintenance
management
Performance
management
Fault
management
Configuration
management
System management
Sverice Acess
Platform
Power Support
Platform
Overhead Processing
Platform
Clock Processing
Platform
NE Control Platform
Hardware System
In terms of functional hierarchy, ZXMP S385 can be divided into hardware system and
network management (NM) software system, which are independent of each other and
work coordinately. The hardware system is the main body of the ZXMP S385. It can
work independently of the NM software system.
A standard "IEC cabinet + sub-rack" structure is used for ZXMP S385. Both the cabinet
and sub-rack unit are designed in the principle of front-facing installation and
maintenance to save equipment space and allow for back-to-back installation, frontfacing operations and maintenance. Appearance of S385 Sub-rack is show in Figure 2 .
12
Figure 2
4.1.2
STM-N
AUG
AU-4
VC-4
3
Pointer processing
TUG-3
TU-3
VC-3
C-3
44736kbit/s
34368kbit/s
C-12
2048kbit/s
C-11
1544kbit/s
TUG-2
3
Multiplexing
TU-12
VC-12
Alignment
Mapping
VC-11
Note:
In above mapping structure, ZXMP S385 V2.00 and above version supports E1/T1,
E3/T3, STM-1 (optical/electrical), STM-4, STM-16, STM-64 and Ethernet services. V2.20
13
and later versions support SAN service. The service enters STM-N via AU-4
multiplexing/mapping route instead of AU-3 multiplexing/mapping route.
T1 service supports VC11-TU12 mapping route.
4.2
Hardware Architecture
With the platform design concept, the ZXMP S385 hardware system consists of the NE
control platform, clock processing platform, service cross platform, overhead processing
platform, power supply support platform and service access platform.
By means of platform establishment, transplant and integration, ZXMP S385 forms
different functional units or boards, which are connected in a specific way to form the
SDH equipment with perfect functions and flexible configurations. ZXMP S385 can be
configured as a TM, ADM, or REG equipment, depending on the networking
requirements. Configurations of REG at rates of 2.5G and 10G are available in V2.00
and above version.
The relationships of all the platforms are shown in Figure 4
Figure 4
Service access
platform
.
.
.
Clock processing
platform
.
.
.
.
.
.
Overhead
processing
platform
Power supply
support platform
Service access
platform
.
.
.
NE control
platform
NE control platform
As the interface between NE equipment and background NMS, the NE control
platform is the agent for other platforms to receive or report network management
information.
14
This platform supports the access of SDH, PDH, Ethernet, ATM and SAN services.
It converts accessed services to corresponding formats, and then forwards them to
the service cross platform for aggregation and distribution.
4
4.3
Software Architecture
ZXMP S385 employs ZXONM E300 to manage and monitor the hardware system and
transmission network, and coordinate the work of the transmission network.
1
15
Figure 5
NE management scope
ZXONM E300 features forward and backward compatibility, capable of managing all
SDH-based multi-service node equipments.
ZXONM E300 V3.19 supports management of ZXMP S385 V2.50 version.
Function introduction
It can perform NE-layer network management functions such as configuration
management, fault management, performance management, security management,
system management, and maintenance management. Please refer to relevant
documentation of ZXONM E300 for details of NMS.
16
Technical Specifications
5.1
Physical Indices
5.1.1
1. Top outlet 2. Decoration door 3. Board area 4. Lower cabling area 5. Fan plug-in box
The subrack consists of four parts:
1
Backplane: the carrier for boards, connects ZXMP S385 to the connection interface
of external signals. The boards are connected to the buses via the board connection
sockets on the backplane.
17
Plug-in board area: it is dual-layer structure used to install ZXMP S385 boards.
Fan plug-in box: located at the bottom of the subrack, it provides forced air cooling
for the equipment to dissipate heat.
The rear part of ZXMP S385 is equipped with one left and one right mounting lugs which
are used to fix the equipment subracks in the cabinet. ZXMP S385 subrack adopts back
fixing installation mode, it can be fixed in the cabinet from the front without obstructing
cable layout, satisfying requirements for front-facing installation, front-facing
maintenance, against wall and back-to-back installation of equipment cabinet.
ZXMP S385 cabinet is 19 cabinet compliant with ETSI standards. It is made of excellent
steel plate and features good electromagnetic shielding and heat dissipation
performances.
5.1.2
Subrack backplane
ZXMP S385 backplane is fixed at the subrack, serving the carrier for connecting all the
boards. It is divided into upper and lower parts, in which, the upper part connects various
functional interface boards, and the lower part connects various functional boards. The
backplane contains service bus, overhead bus, clock bus, board-in-position bus,
connects all the boards, equipment and external signals via interfaces and sockets.
Backplane adopts unified arrangement of bus arrays of payload services, auxiliary
services, internal board-to-board communication and clock, thus ensures the equipment
to add boards with various types of interfaces according to customers requirements.
5.1.3
18
Figure 8
5.2
Dimension (mm)
Weight
(kg)
70
80
90
25
Power distribution
box
--
Ventilation unit
--
Cross-connect clock
board
(CSA/CSE/CSF)
--
Structural part
19
Structural part
Dimension (mm)
Weight
(kg)
Service interface
board and ENCP, OW
--
--
Cabinet height
Power
distribution
box
Subrack
2.0m (with
effective height of
42U)
3U
2.2m (with
effective height of
47U)
3U
2.6 m (with
effective height of
56U)
3U
Table 8
Cabinet height
20
Power
distribution
box
Subrack
3U
3U
3U
3U
Cabinet height
Power
distribution
box
Subrack
3U
3U
3U
3U
+1U,+2U,+3U in the table are space reserved for dustproof, ventilation and cabling.
5.3
21
Figure 9
5.4
22
Board
Power
Consum
ption in
Common
Temperat
ure (25 )
(W)
Max.
Power
Consum
ption
(45 ) (W)
Weight
(Kg)
NCP
4.8
0.44
ENCP
9.6
9.9
0.46
OW
Order-wire
5.3
5.4
0.47
QxI
3.9
4.1
0.52
CSA
27.4
28.2
1.14
Board
Power
Consum
ption in
Common
Temperat
ure (25 )
(W)
CSF
32.4
33.4
1.46
TCS64
17.3
17.8
0.56
TCS128
36.5
37.6
0.95
TCS256
60.5
62.3
0.98
SCIB
3.9
4.0
0.51
SCIH
4.4
4.5
0.61
OL64FE
C
25
27.3
1.12
OL64
28.8
31.2
0.95
OL64x2
31.9
34.3
1.12
OL16
14.9
16.3
0.65
OL164
23.6
28.3
1.30
OL168
33.5
38.2
1.43
OL42
10.1
10.4
0.70
OL44
16.8
17.3
0.74
OL14
8.9
9.2
0.74
OL18
14.4
14.8
0.80
OEL116
18.1
18.6
0.87
OEIS1x8
6.4
6.4
0.38
LP14
5.8
0.65
LP18
5.8
0.68
Max.
Power
Consum
ption
(45 ) (W)
Weight
(Kg)
23
Power
Consum
ption in
Common
Temperat
ure (25 )
(W)
Max.
Power
Consum
ption
(45 ) (W)
Weight
(Kg)
Before
switchove
r 0.5,
after
switchove
r 8.2
Before
switchove
r 0.6,
after
switchove
r 8.4
0.40
ESS18
Before
switchove
r 0.5,
after
switchove
r 8.2
Before
switchove
r 0.6,
after
switchove
r 8.4
0.47
EP36
12.5
12.9
0.71
ESE36
Before
switchove
r 0.5,
after
switchove
r 5.3
Before
switchove
r 0.6,
after
switchove
r 5.4
0.40
BIE3
0.5
0.6
0.37
EPE163
(75)
19
19.6
0.81
EIE163(
75)
0.5
0.6
0.36
ESE163
(75)
Before
switchove
r 0.5,
after
switchove
r 21.6
Before
switchove
r 0.6,
after
switchove
r 22.2
Before
switcho
ver 0.6,
after
switcho
ver 8.4
EPE163
(120)
19
19.6
0.83
EPT163
(100)
15.4
15.8
0.81
EIT163
0.5
0.6
0.35
Before
switchove
r 0.5,
after
switchove
r 21.1
Before
switchove
r 0.6,
after
switchove
r 21.8
0.54
Board
ESS14
EST163
24
Board
Power
Consum
ption in
Common
Temperat
ure (25 )
(W)
BIE1
0.5
0.6
0.39
SEE
26.4
27
0.75
RSEB
29.4
30.3
0.98
AP18
24.1
24.9
0.85
TGE2B
19.1
19.7
0.73
TGSA8
36.5
37.6
0.99
OIS18
7.0
7.2
0.45
OEIFEx8
8.5
8.5
0.45
ESFE8
0.6
0.7
0.38
OADD
4.1
0.75
OADC
3.5
3.6
0.75
FAN
Fan board
4.2
4.3
0.36
OBA12
6.1
11.6
1.15
OBA14
6.1
11.6
1.15
OBA17
6.1
11.6
1.15
OBA19
6.1
11.6
1.15
OPA32
4.8
10.3
1.18
OPA38
4.8
10.3
1.18
Max.
Power
Consum
ption
(45 ) (W)
Weight
(Kg)
25
5.5
155520kbit/s
Classification code
S-1.1
L-1.1
L-1.2
1310
1310
1550
Source type
MLM
SLM
SLM
-15
-5
-5
-8
8.2
10
10
-28
-34
-34
-8
-10
-10
Table 11
622080kbit/s
Classification code
S-4.1
L-4.1
L-4.2
1310
1310
1550
Source type
MLM
SLM
SLM
-15
-3
-3
-8
8.2
10
10
-28
-28
-28
-8
-8
-8
G.957-compliant
Table 12
26
2488320kbit/s
Classification code
S16.1
L16.2
L16.2JE
L16.2P
L16.2U
1310
1550
1550
1550
1550
Source type
SLM
SLM
SLM
SLM
SLM
2488320kbit/s
-5
-2
+2
-2
-2
8.2
8.2
8.2
8.2
8.2
-18
-28
-28
-28
-28
-9
-9
-9
-9
G.957-compliant
Table 13
9953280kbit/s
10709225kbit/s
Classification code
S64.2b
L64.2c1
L64.2c2
P1L12D2
P1L1-2D2
1550
1550
1550
1550
1550
Source type
SLM
SLM
SLM
SLM
SLM
-1
-2
8.2
8.2
8.2
-14
-22
-22
-24
-24
-1
-9
-9
-7
-7
G.709compliant
G.691 or G.959.1-compliant
5.6
Type
1544
kbit/s
2048
kbit/s
34368
kbit/s
44736
kbit/s
155520
kbit/s
Code pattern
AMI or
B8ZS
HDB3
code
HDB3
code
B3ZS
code
CMI code
G.703complia
nt
G.703complia
nt
G.703complian
t
G.703complian
t
G.703compliant
27
1544
kbit/s
Type
2048
kbit/s
34368
kbit/s
44736
kbit/s
155520
kbit/s
Frequency deviation
tolerance at input port
Anti-interference capability
of input port
Permitted input port attenuation, permitted frequency deviation and output port signal bit
rate tolerance are listed in the following Table 15 .
Table 15 Input port permitted attenuation, frequency deviation and output port signal bit rate
tolerance
Interface
rate
1544kbit/s
--
2048 kbit/s
0dB~6dB, 1024kHz
34368
kbit/s
0dB~12dB, 17,184kHz
44736
kbit/s
--
155520
kbit/s
0dB~12.7dB, 78MHz
Table 16
Test frequency
range
Reflection attenuation
(dB)
51.2kHz~102.4kHz
12
102.4kHz~2048kHz
18
2048kHz~3072kHz
14
860kHz~1720kHz
12
1720kHz~34368kHz
18
34368kHz~51550kHz
14
8MHz~240MHz
15
28
waveform
complies
with
template
specified
in
G.703
5.7
5.7.1
5.7.2
Performance of SEE
Performance of TGE2B
TGE2B board provides 2GE adaptive Ethernet services.The performance is show as
Table 17 .
29
Table 17
Property sort
Board name
TGE2B
1000BASE-SX/LX
Connector
LC
Support
Support
Ethernet port
Interface
mode
Front-outlet on panel
Support
2
2.5G
Virtual
concatenation
Support
Support
Support
Support
Support
LCAS protocol
Encapsulation
protocol
30
Support the
flow control
based on port
Support
The
intercommunic
ation of
different
products inside
company
VC4-level intercommunicating
with EOS series boards, RPR
functional RSEB board
Ethernet
performance
Support
Point-to-point
transparent
transmit
(private service
mode)
5.7.3
Performance of RSEB
RSEB maps Ethernet service to RPR, and performs the unique functions of RPR. It uses
the channel bandwidth resource of SDH/MSTP ring network to provide the dual-ring
topology required by RPR and implement the ring interconnection of RPR nodes.
RSEB provides user Ethernet interfaces as 8FE (optical/electrical) +2GE (optical). It
provides FE optical or electrical board by cooperating with OIS18 or ESFE interface
board respectively.
RSEB board provides two RPR ports and four EOS port at system side:
RPR at system side contains two RPR SPAN: RPR SPAN1 and RPR SPAN2 with
mapping methods of VC-4-Xv, VC-3-Xv, backplane bandwidth is 2.5G, capable of
constructing 1.25G RPR.
RPR board at system side provides four EOS ports with mapping method of VC-12Xv and a maximum bandwidth of 63VC12.
EOS system port can be used for RPR service cross-ring, or intercommunication with
EOS boards as SEE . It supports LCAS protocol.
RPR SPAN port and EOS system port share the 2.5 Gbit/s SDH processing bandwidth.
They support maximum 2.5 Gbit/s of RPR ring total bandwidth, and maximum 155 Mbit/s
ZTE Confidential Proprietary
31
of EOS bandwidth (RPR ring total bandwidth and EOS bandwidth cannot reach the
maximum values simultaneously).
RSEB board has the following functions:
5.7.4
Compliant with IEEE802.17, support for two RPR SPAN, capable of forming 1.25G
bidirectional ring at most;
Support for interoperation of RPR ring and EOS chain, implementing conversion of
mapping granules;
Support for Bypass RPR MAC function, used as EOS transparent transmission
board to support transparent transmission of two GE+4 FEs;
EOS port supporting CSF OAM function, with point-to-point LST function available;
Support for IGMP Snooping broadcast protocol, support for IPTV application;
Performance of AP18
AP18 board is mainly used to converge or aggregate ATM service data to SDH
transmission network. It provides 8155 Mbit/s optical interfaces at the ATM side to
perform functions as ATM layer processing and mapping from ATM cell to VC-4. It
provides 1622 Mbit/s non-concatenation data flow at the system side. With 622M
backplane bandwidth and 622Mbps cell switching capacity, it can select 1-4 VC-4
channels to transmit ATM services.
32
Supports four ATM service types as constant bit rate (CBR), realtime variable bit
rate (rt-VBR), non-realtime variable bit rate (nrt-VBR) and unspecific bit rate (UBR).
5.7.5
Supports ATM space, logic multicast, when performing ATM exchange, it can copy
one input ATM cell flow (VP, VC) to multiple output ATM links.
Performance of TGSA8
TGSA8 has SAN and GE transparent transmission interface. It supports 8 user
interfaces which adopt SFP optical module. The first 4 user interfaces may respectively
offer GE or SAN service. SAN service includes 1G Fiber Channel and 1G FICON
services. The other 4 user interfaces may offer 4GE services.
TGSAx8 provides 42.5G service bus at the system side. The total bandwidth is 10G.
Other characteristics of TGSAx8 are showed as follows:
Support VC-3 and VC-4 mixed concatenation. Any VCG may be respectively
configured to VC-3 or VC-4 virtual concatenation. VC-3 supports VC-3-->TU-3->AU-4 mapping path.
5.8
5.8.1
Type
Rate (bps)
followed
standard
Interface type
interface
10BASE-T
10M
IEEE 802.3
Electronic
interface
RJ45,
category 3
UTP
100BASE-TX
100M
IEEE 802.3u
Electronic
interface
RJ45,
category 3
UTP
33
Type
Rate (bps)
followed
standard
Interface type
interface
100BASE-FX
100M
IEEE 802.3u
M-1.1/S-1.1/L-1.1
SFP-LC
Table 19
Item
62.5/125m MMF
MMF LD
Transmission distance
Interface
SFP-LC
Unit
KM
Wavelength (, range)
1270~1380
nm
Trise/Tfall (maximum;10%~90%)
ns
63
nm
-14
dBm
-20
dBm
-45
dBm
10
dB
Table 20
Item
62.5/125m MMF
Unit
Wavelength(, range)
1270~1380
Nm
-14
dBm
Receiver sensitivity
-30
dBm
34
Table 21
Item
10/125m SMF
SMF LD
Transmission distance
15
Interface type
SFP-LC
Wavelength(, range)
1261~1360
nm
Trise/Tfall (maximum;20%~80%)
2.5
ns
7.7
nm
-8
dBm
-11.5
dBm
-45
dBm
Extinction ratio(minimum)
dB
Table 22
Unit
KM
Item
10/125m SMF
Unit
Wavelength (, range)
1261~1360
nm
-8
dBm
Receiver sensitivity
-31
dBm
Table 23
Item
10/125m SMF
SMF LD
Transmission distance
40
Interface type
SFP-LC
Wavelength (,range)
1261~1360
nm
2.5
ns
nm
dBm
-5
dBm
-45
dBm
10
dB
Unit
KM
35
Table 24
5.8.2
Item
10/125m SMF
Unit
Wavelength ( range)
1261~1360
Nm
-9
dBm
Receiver sensitivity
-34
dBm
GE interface index
Type
Rate(bps)
followed
standard
Interface type
interface
1000BASE-SX
1000M
IEEE 802.3z
M-1.8
SFP-LC
1000BASE-FX
1000M
IEEE 802.3z
S-1.1 or L-1.2
SFP-LC
Table 26
36
Item
62.5/125m MMF
MMF LD
Transmission distance
275
Interface
SFP-LC
Unit
m
Wavelength (, range)
830~860
nm
Trise/Tfall (maximum;10%~90%)
0.26
ns
0.85
nm
-4
dBm
-9.5
dBm
-35
dBm
RIN(maximum)
-117
dB/Hz
Extinction ratio(minimum)
dB
Table 27
Item
62.5/125m MMF
Unit
Wavelength(,range)
770~860
nm
dBm
Receiver sensitivity
-17
dBm
12
dB
-12.5
dBm
Table 28
Item
10/125m SMF
Unit
SMF LD
Transmission distance
10
Interface type
SFP-LC
Wavelength(,range)
1270~1355
nm
Trise/Tfall (maximum;20%~80%)
0.26
ns
2.8
nm
KM
-3
dBm
-9.5
dBm
-35
dBm
Extinction ratio(minimum)
dB
RIN(maximum)
-120
dB/Hz
Table 29
Item
10/125m SMF
unit
Wavelength ( ,range)
1270~1355
nm
-3
dBm
Receiver sensitivity
-20
dBm
-14.4
dBm
37
Table 30
Item
10/125m SMF
SMF LD
Transmission distance
80
Interface type
SFP-LC
Wavelength (,range)
1540~1570
nm
Trise/Tfall (maximum;20%~80%)
2.5
ns
0.16
nm
dBm
dBm
-45
dBm
Extinction ratio(minimum)
dB
RIN(maximum)
-120
dB/Hz
Table 31
5.9
Unit
Km
Item
10/125m SMF
Unit
Wavelength(,range)
1270~1600
nm
dBm
Receiver sensitivity
-22
dBm
-14.5
dBm
Performance of OAD
OAD board consists of OADD and OADC.
OAD board may process the control commands from NM to make the online
upgrade of board software.
38
Table 32
Performance of OADD
Item
Unit
Frequency Range
Min
Max
THz
192.1
196.0
Wavelength Range
nm
1529.55
1560.61
Channel Spacing
GHz
100
0.5 dB Passband
nm
0.11
20dB Passband
nm
1.20
In-drop
dB
2.5
3.3
Add-out
dB
2.5
3.3
In-out
dB
2.4
dB
1.0
Insertion Loss
Table 33
Performance of OADC
Item
Unit
Channel Number
Parameter
6
Central wavelength
nm
1471/1491/1511/
1531
1471/1491/15
11/1531
1551/1571/15
91/1611
Passband @ 0.5dB
nm
6.5
6.5
6.5
Wavelength range of
upgrade port
nm
1544.5~1621
1544.5~1621
dB
0.5
0.5
0.5
@ 1310
Port
dB
0.7
nm
1260~1360
LnCWDM
dB
2.3
2.0
UPGCWDM
dB
1.7
Ln
UPG
dB
2.3
2.0
Ln 1310nm
dB
1.2
Ripple
Insertion
Loss
(Including
connectors)
5.10
Parameter
Performance of OBA
Performacen of OBA is show in Table 34 .
39
Table 34
Performance
Unit
OBA12
OBA14
OBA17
Operating wavelength
nm
1530~1565
1530~1565
1530~1565
Input power
dBm
-12~4
-12~4
-6~4
Output power(maximum)
dBm
12
14
17
Dynamic range of
output power (dB)
dB
Gain
dB
5~24
7~26
10~23
dB
>25
>25
>25
Noise Index
dB
dB
45
45
45
dB
45
45
45
dBm
-30
-30
-30
dBm
-30
-30
-30
PDG
dB
0.5
0.5
0.5
PMD
ps
Power(full temperature
range)
<25
<25
<25
-15~65
-15~65
-15~65
Operating temperature
Operating humidity
5~95
5~95
5~95
Storage temperature
-40~75
-40~75
-40~75
Optical Connector
LC/PC
LC/PC
LC/PC
5.11
Performance of OPA
Performance of OPA is show in Table 35 .
Table 35
40
Performance
unit
OPA38
OPA32
Operating wavelength
nm
1550.12
1550.12
Filter-3dB bandwidth
nm
0.45
0.45
nm
1.2
1.2
Input power
dBm
-38~20
-32~15
Output power(maximum)
dBm
-9
-6
dB
Gain
dB
26~32
25~31
dB
30
30
Noise Index
dB
4.5
4.5
Performance
unit
OPA38
OPA32
dB
45
45
dB
45
45
dBm
-30
-30
dBm
-50
-50
dBm
-30
-30
dBm
-30
-30
Pump wavelength
nm
980
980
PDG
dB
0.2
0.2
PMD
ps
Power
15
15
Power supply
-4810%
-4810%
Operating temperature
-15~65
-15~65
5~95
5~95
Storage temperature
-40~75
-40~75
Optical Connector
LC/PC
LC/PC
Operating humidity
5.12
Performance of DCM
The Dispersion Compensating Modules compensates the dispersion of conventional
single mode fiber (G.652/G.655) Performance of the DCM is show in Table 36 .
Table 36
Type
DCM-20
DCM-40
DCM-60
DCM-80
DCM-100
Dispersion
compensated
range(ps/nm)
-32915
-68021
102031
-136041
-164041
Insert loss(dB)
4.1
5.1
7.0
8.9
12.1
-11.5
typical value
-3.2
-4.4
-6
-7.7
PMD(2-step)
0.5
1.0
1.2
1.3
PMD(Typical)(ps)
-0.4
-0.4
-0.5
-0.6
0.1
0.1
0.1
PMD cost(dB)
Note:
41
5.13
Error Performance
For each circuit direction and for bi-directional section and path, the error performance is
monitored separately, the SDH performance of ZXMP complies with ITU-T G.784, G.828
and G.826. The SDH performance includes performance items such as BBE, ES, SES,
FBBE, FEES, FESES, PSC, PJC+, PJC-, UAS, etc.
The long term and short-term error performances of ZXMP S385 are complied with ITUT G.828 and M.2101 recommendation. According to ITU-T G.821 and G.826, in 420km
HRDP (Hypothetical Reference Digital Path), SDH system error performance of ZTEs
transmission product is as follows, these figures are tested in field and test duration is
not less than 24 hour. SDH system error performance is show in Table 37 .
Table 37
Bit
rate(kbit/s)
2048
ESR
1.84810
SESR
9.2410
BBER
44736
-6
-8
-9
9.2410
155520
-6
3.46610
-8
9.2410
-9
9.2410
622080
-6
7.39210
-8
9.2410
-9
9.2410
2488320
-5
1.84810
-5
3.710
-8
9.2410
-9
9.2410
9.2410
9.2410
-8
-9
5.14
5.14.1
42
A0
A3
A1
A2
f0
f10 f9
f8
f1
f2
f3
f4
Jitter frequency
(logarithm)
Table 38
Interfa
ce rate
UIp-p
(kbit/s)
A0
A1
A2
1544
18
5.0
UI
0.
1U
I
2048
36.
9
18
0.
2
18
4.881
0-3
0.0
1
34368
618
.6
1.5
0.
15
ffs
ffs
ffs
44736
18
5.0
UI
0.
1U
I
Pseudo
random
Frequency (Hz)
A
3
f10(T1
/T3 is
f0)
f9
f8
f1
f2
f3
f4
signal
10
12
0
6k
40
K
220 1
1.6
67
20
2.4
k
18
k
10
0k
215-1
ffs
10
0
1k
10
k
80
0k
223-1
10
60
0
30
k
40
0k
220 1
1.210
5
1.2
105
43
Table 39
Parameter
value
Digit rate
(kbit/s)
Network limit
B1 unit
interval
B2 unit
interval
peak-to-peak
peak-topeak
f3
f4
8kHz
40KHz
1 544
0.1
10Hz
2 048
1.5
0.2
20 Hz
34 368
1.5
0.15
100 Hz
10 kHz
800 kHz
44736
0.1
10Hz
30kHz
400kHz
18 kHz
(700 Hz)
100 kHz
Note:
For the co directional interface only.
The frequency values shown in parenthesis only apply to certain national interfaces.
UI Unit Interval: for 2048 Kbit/s 1 UI = 488 ns; for 34 368 Kbit/s 1 UI = 29.1 ns
5.14.2
44
f12
f0
Table 40
f11
f10
f9
f8
f1
f2
f3
f4
Frequency
STM
interface
A0 (18s)
A1 (2 s)
A2 (0.25 s)
A3
A4
STM-1
2800
311
39
1.5
0.15
STM-4
11200
1244
156
1.5
0.15
STM-16
44790
4977
622
1.5
0.15
Table 41
STM
interface
f0
f12
f11
f10
f9
f8
f1
f2
f3
f4
STM-1
1.2
10-5
1.78
10-4
1.6
10-3
1.56
10-2
0.125
19.3
500
6.5k
65k
1.3M
STM-4
1.2
10-5
1.78
10-4
1.6
10-3
1.56
10-2
0.125
9.65
1000
25k
250k
5M
STM-16
1.2
10-5
1.78
10-4
1.6
10-3
1.56
10-2
0.125
12.1
5000
100k
1M
20M
45
UI
P-P
A2
Slope: -20dB/10 octave
A1
Table 42
f1
Frequency
STM interface
STM-1
STM-4
STM-16
5.14.3
f2
f1 (kHz)
f2 (kHz)
A1 (UIP-P)
A2 (UIP-P)
65
6.5
0.15
1.5
12
1.2
0.15
1.5
250
25
0.15
1.5
12
1.2
0.15
1.5
1000
100
0.15
1.5
12
1.2
0.15
1.5
STM interface
STM-1
STM-4
STM-16
46
Test filter
500Hz~1.3MHz
0.50 UI
65kHz~1.3MHz
0.10 UI
1000Hz~5MHz
0.50 UI
250kHz~5MHz
0.10 UI
5000Hz~20MHz
0.50 UI
1MHz~20MHz
0.10 UI
Table 44
STM interface
f1 (Hz)
f3 (kHz)
f4 (MHz)
B1 (UIp-p)
B2 (UIp-p)
STM-1 optical
interface
500
65
1.3
1.5
0.15
STM-1 electrical
interface
500
65
1.3
1.5
0.075
STM-4 optical
interface
1000
250
1.5
0.15
STM-16 optical
interface
5000
1M
20
1.5
0.15
For the REG equipment, when the test filter adopts 12 kHz high-pass filter, its root mean
square value (RMS) created from jitter should not be greater than 0.01UIrms.
5.14.4
G.703
interface
Tolerance
(ppm)
(kbit/s)
5.14.5
f1 (Hz)
f3 (Hz)
f4 (Hz)
f1~f4
f3~f4
2048
50
20
18k
100k
Undetermined
0.08
34368
20
100
10k
800k
Undetermined
0.08
44736
20
100
10k
800k
Undetermined
0.08
Combined Jitter
In the SDH system, generally, there are both mapping jitter and pointer adjusting jitter.
The combined jitter of both is called the combined jitter. Under various test sequences,
the value detected by ZXMP S385 should meet the ones listed in Table 46 .
Table 46
Combined jitter
PDH
inter
face
Bit
rate
toler
ance
(kbit/
s)
(ppm
)
f1
(Hz)
f3
(Hz)
f4
(Hz)
f1~f4 (UIp-p)
f3~f4 (UIp-p)
2048
50
20
18k
100
k
0.4
0.4
0.4
0.0
75
0.0
75
0.0
75
3436
8
30
100
10k
800
k
0.4
0.4
0.4
0.0
75
0.0
75
0.0
75
0.
75
47
0.0
75
PDH
inter
face
Bit
rate
toler
ance
4473
6
30
100
10k
Test sequence
5.14.6
0.4
0.4
0.4
0.
75
0.0
75
0.0
75
0.0
75
0.0
75
(UI P-P )
A2
Slope: -20dB/10 octave
A1
f2
f1
Frequency
STM-N
A
STM-1
STM-4
STM-16
5.15
fc (kHz)
P (dB)
130
0.1
30
0.1
500
0.1
30
0.1
2000
0.1
30
0.1
48
Table 48
Vendor
ISOTEMP
Type
OCXO
77.76MHz
110-8
510-7
110-7(0V)
110-10/s
Temperature characteristic
510-8(0~50C)
Output jitter
When there is no input jitter, the inhered jitter of ZXMP S385 2M clock output
interface should not be over 0.05 UIP-P. The test is conducted at an interval of
every 60 seconds with a single-pole band-pass filter in 20Hz and 100kHz turnover
frequencies.
Table 49
MTIE limits
Observation interval
40 ns
0.1s 1s
40 0.1 ns
1s 100s
25.25 0.2 ns
100s 1000s
Table 50
Observation interval
0.5ns
0.1s
50ns
118s
Table 51
100s
MTIE limits
Observation interval
3.2 ns
0.1s
25s
49
MTIE limits
0.64
6.4 ns
0.5 ns
Observation interval
25s
100s
100s
1000s
For a reference that can follow the G.811 clock, the SEC output frequency accuracy in
the free-run mode should not be greater than 4.6ppm for SDH terminal equipment and
20ppm for REG equipment. ZXMP S385 can satisfy the above requirements.
50
Environment Adaptability
6.1
6.2
Range: -57VDC~-40VDC
Grounding requirements
If separate grounding is adopted in the equipment room, the grounding resistance
should meet the following requirements:
The grounding resistance for the system working ground is less than or equal to 4.
The grounding resistance for the lightning protection ground is less than or equal to
4.
If the combined grounding is adopted in the user equipment room, the grounding
resistance should be less than or equal to 1.
The voltage difference among lightning protection ground, system working ground and 48V GND should be less than 1V.
The tandem requirements between all groundings are as follows:
The -48V ground of the board is isolated from the -48V GND.
The board shielding plate is connected to the cabinet via the front panel, and there
is an electrical connection with the co-module filter capacitor inside a board.
The lightening protection GND only connects to the protection component, and
converges with the system working GND at the grounding terminal on the bus bar of the
rack. The -48V GND can converge with the PGND, or the combined GND on the bus bar
of the rack, or be grounded outside.
51
6.3
Environment requirements
6.3.1
Operation Environment
1
Climate
Climate requirement is show in Table 52 .
Table 52
Climate requirement
Item
Range
Altitude
4000m
Air pressure
70 ~ 106kPa
+5 ~+40
0 ~+45
0.5
20%~80%
10%~90%
Heat radiation
300W/s
/min
In the normal working environment, the measuring point of the temperature and
humidity refers to data obtained at the place 1.5 meters above the floor and 0.4m
meters in front of the equipment. The short-term working refers to working
continuously for no more than 48 hours and no more than accumulated 15 days in a
year.
2
Biological environment
Avoid multiplication of microbe, such as eumycete and mycete.
Avoid the rodent, e.g., mice.
Air cleanliness
Density requirements for chemical active substances is show in Table 53
Table 53
52
Content
mean (mg/m)
Max( mg/m)
SO2
0.3
H2S
0.1
0.5
NH3
Cl2
0.1
0.3
HCl
0.1
0.5
HF
0.01
0.03
Content
mean (mg/m)
Max( mg/m)
O3
0.05
0.1
NO2
0.5
Content
Perceivable dust
= 15 mg/mh
Mechanical stress
Requirements for mechanical stress is show in Table 55 .
Table 55
Item
Unit
Value
Acceleration
m/S2
0.1
Frequency range
Hz
5~100, 100~5
direction
X,Y,Z
duration
Min
90
Condition of earthquake
According with:NEBS GR-63
IEC721-2-6 Environmental conditions appearing in nature-Earthquake vibration
IEC68-3-3 Environmental testing - Part 3: Background information - Subpart 3:
Guidance. Seismic test methods for equipment
6.3.2
Climate
Table 56
Climate requirement
Item
Range
Altitude
4000m
Air pressure
70 ~ 106kPa
53
Item
Range
Temperature
-40 ~ +70
0.5C/min
Relative humidity
10% ~ 100%
Solar radiation
600W/s
Air speed
30m/s
Mechanical stress
Table 57
Item
unit
value
Acceleration
m/S2
0.1
Frequency range
Hz
5~100, 100~5
direction
X,Y,Z
duration
Min
90
The earthquake-proof performance of the whole equipment complies with Earthquakeproof Performance Detection for SDH Optical Communications Equipment (Provisional)
and Earthquake-proof Performance Detection for SDH Optical Communications
Equipment (Provisional). The earthquake-proof performance detection reaches the
eight-level intensity.
6.3.3
Cleanness requirements
Cleanness involves dust and harmful gases in the air. The equipment should be
operated in the equipment room that meets the cleanness requirements described below:
6.3.4
The density of dust particles with the diameter greater than 5m should be no more
than 3104 particles/m3.
No corrosive metal or gases that are detrimental to the insulation exist in the
equipment room, such as SO2 and NH3.
The equipment room should be always kept clean, with doors and windows being
closed.
54
Before introducing the EMC requirements, firstly specifies 3 criteria for test results:
6.3.5
Table 58
Contact discharge
Air discharge
6kV
8kV
Performance B
8kV
15kV
Performance R
Table 59
Amplitude modulation
10V/m
80%AM (1kHz)
Performance A
55
Table 60
Repeated frequency
1kV
5kHz
Performance B
Table 61
Electrical fast transient burst susceptibilities at the signal cable and control cable ports
Repeated frequency
1kV
5kHz
Performance B
Surge susceptibility
The surge susceptibility of ZXMP S385 equipment is shown in Table 62 , Table 63
and Table 64 .
Table 62
Test voltage
Line to ground
1kV
Performance B
Line to ground
2kV
Performance R
Table 63
Table 64
Test voltage
2kV
Performance B
4kV
Performance R
Test voltage
Line to ground
1kV
Performance B
Line to ground
2kV
Performance R
56
Table 65
Amplitude modulation
3V
80%AM (1kHz)
Performance A
Table 66
Limits (dBuV)
Quasi-peak
Mean value
0.02~0.15
79
--
0.15~0.5
79
66
0.5~30
73
60
Table 67
6.4
3m
30~230
40
50
230~1000
47
57
230~1000
47
57
Safety requirements
This product adopts the technical requirements specified in the following standard:
57
Optical interface
The optical module of the maximum power belongs to (Class 3A). All the optical
modules shall be under strict control and certified by authorities (such as UL, TUV
and NEMKO), and comply with EN60825.
Fuse
All the fuses and power modules, including recoverable fuses, shall be certified by
authorities such as CE, UL and TUV.
Safety mark
On the package of the equipment, there are striking labels about antistatic, fragile,
waterproof, and damp-proof.
The maximum optical power satisfies the 3A safety standard. An obvious label
warning against the laser shall be pasted at the optical interface.
Cables of different colors shall be used for the power input, shielding GND and
lightening protection GND to avoid incorrect connection. Different power connectors
shall use coding keys. There shall be a power label at the power inlet.
Both the equipment and each board shall have an antistatic label.
Grounding symbol
indicates switch-off.
Mechanical structure
In installation, four bolts are designed at the rack bottom (may also be used to
adjust balance) to fix the rack to the ground. At the rack top, the corresponding
screws are designed to fix the rack to the cabling rack. When installed in the
equipment room, the rack shall be fixed both at the top and bottom to ensure the
stability and safety of the equipment.
The corners of both the rack and sub-rack are processed to avoid hurting people.
Fire protection
The materials of the circuit boards in the equipment use the fireproof materials of
the V-2 level to prevent the circuits from burning in case of failure.
The structural parts use unburnable materials with a good fireproof performance,
including surface processing materials.
58
With the effective heat dissipation design, it ensures that the temperature does not
exceed 70C to prevent heat aggregation and reduce the possibility of burning.
Safe parts passing the safety authentication (CE, UL, etc.) are used.
Lightening protection
In this system, good grounding and isolation and protection of electrical interfaces
are used to prevent the dangerous voltage of lightening.
59
Glossary
Abbreviations
60
Full Name
ADM
Add-Drop Multiplexer
AFEC
AIS
ANSI
APS
ASIC
ASON
ATM
AU
Administrative Unit
AUG
AU-n
AU-PTR
BBE
BBER
BER
BITS
BML
CBR
CDM
CLP
CMI
C-n
Container- n
CORBA
CV
Code Violation
CWDM
DB
Data Base
DBMS
DCC
DCE
DCF
DCN
DDN
DLL
DNA
DNI
Abbreviations
Full Name
DQDB
DTE
DWDM
DXC
ECC
EDFA
EM
Element Management
EMC
Electromagnetic Compatibility
EMI
Electromagnetic Interference
EML
EMS
EOS
ES
Error Second
ESD
ESR
ETS
ETSI
FDDI
FDM
FE
Fast Ethernet
FEBBE
FEC
FEES
FESES
GUI
HDLC
HPC
HW
High-Way
IEC
IEEE
IP
Internet Protocol
ITU-T
L2
Layer 2
LAN
LAPD
61
62
Abbreviations
Full Name
LAPS
LCD
LCT
LOF
Loss Of Frame
LOP
Loss Of Pointer
LOS
Loss Of Signal
LPC
MAC
MAN
MCF
MCU
MD
Mediation Device
MF
Mediation Function
MII
MM
Multi Mode
MS
Multiplex Section
MS-AIS
MSOH
MSP
MS-PSC
MS-PSD
MS-SPRing
MST
MTIE
NE
Network Element
NEF
NEL
NML
NMS
NRZ
Non-Return-to-Zero
OAM
OFS
OOF
Out of Frame
OS
Operation System
OSF
Abbreviations
Full Name
OSI
PCB
PCM
PDH
PGND
Protection GND
PHY
PJE-
PJE+
POH
Path OverHead
PPP
PRC
QA
Q Adaptor
QAF
Q Adaptor Function
QoS
Quality of Service
RAM
RDI
REG
Regenerator
REI
RFI
RIP
RMII
RS
Regenerator Section
RSOH
SAR
SDH
SEC
SEMF
SES
SESR
SETS
SM
Single Mode
SMCC
SML
SMN
SMS
SMT
SNC
Sub-network Connection
SNCP
63
64
Abbreviations
Full Name
SOH
Section Overhead
SPRING
SSF
SSM
SSM
STM-N
TCP
TDEV
Time Deviation
TDM
TM
Terminal Multiplexer
TMN
Telecommunications Management
Network
TTL
Transistor-Transistor Logic
TU
Tributary Unit
TUG-m
TU-m
UART
UAS
Unavailable Second
UBR
UNI
User-Network Interface
UPC
VBR
VC
Virtual Channel
VC
Virtual Container
VCI
VC-n
VDN
VLAN
VP
Virtual Path
VPI
VPG
VP Group
WAN
WDM
WS
Work Station
WSF
ZXMP