You are on page 1of 1

Large-scale NTP tech.

efforts for flue-gas cleaning 12

Power Flow rate Target gases Additives SIE


Institution Year Reactor DRE
supply (Nm3/h) (ppm) (ppm) (Wh/Nm3)
NOx
Wire-plate NH3 60%
ENEL, It. 1990 Pulse 1,000 (430~550) ~ 15
(plasma+ESP) CaOH2 80%
SO2 (360~500)

Pulse NOx 50%


Korea Cottrell 1998 Wire-plate 10,000 NH3 X
(RSG) SO2 89%

Dalian Univ. Pulse


1998 Wire-plate 1,400 SO2 (2000) NH3 3.9 80%
Ch. (RSG)

Masuda Dioxin
DC-bias Propane
Research Inc., 2001 Wire-cylinder 6,700 Dust ~6 ~92.4 %
pulse (100)
Jp. ( <5mg/Nm3 )
Wire-plate Pulse NOx (73) 60%
RIST, Ko. 2001 5,000 C3H6 (48) 4
(Plasma+ESP) (MPC) SO2 (150) 90%
Doosan-Heavy Pulse 1,700 NOx (300) NH3 9 70%
2003 Retrofitted ESP
Industry, Ko. (MPC) 100,000 SO2 (300) C2H4 (600) X 95%
Takuma
Co.,Jp. Surface corona
2003 AC (16kW) 51,000 Odor - 0.2 99%
with catalyst
(WWTP)
POSTECH, Pulse NOx (120) NH3 (370) 70%
2003 Wire-plate 42,000 1.4
Ko. (MPC) SO2 (150) C3H6 (55) 99%

POSTECH
POSTECH Plasma Sheath Laboratory