You are on page 1of 2

Alliance Thermal Fluid Heaters

Horizontal Coil Design Thermal Fluid Heaters

Sizes from 2,400,000 to 20,000,000 BTU/HR

The heat transfer innovators.

SPECIFICATIONS AND DIMENSIONS


Models

HC

0240

0400

0600

0800

1000

1200

1600

2000

1,000 BTU/HR
GPM

2,400
150

4,000
300

6,000
400

8,000
600

10,000
850

12,000
1,200

16,000
1,200

20,000
1,500

GPH
FT3/HR

23
3,200

39
5,340

58
8,000

77
10,700

96
13,340

115
16,000

143
20,000

179
25,000

HP
HP

15
2

25
5

30
7.5

50
10

60
15

75
15

100
30

125
30

IN
IN
IN
IN
IN
GAL
LB

64
12
62
134
2.5
75
5,000

68
14
62
137
3
115
7,500

78
18
81
157
4
190
9,500

107
22
95
182
6
264
12,500

107
22
95
182
6
325
19,250

125
22
130
240
6
508
21,700

114
36
118.5
327
8
480
39,000

118
36
119.5
351
8
1,150
39,000

Specifications
Heat Output
Recommended Flow Rate

Approximate Fuel Usage


Light Oil
Natural Gas

Power
Circulating Pump Motor
Blower Motor

Dimensions
Overall Height (with Stack)
Stack Diameter
Overall Width
Overall Length
Inlet/Outlet Connections
Thermal Liquid Volume
Approx. Dry Weight

Specifications and Dimensions are approximate. Consult factory for model specific electrical requirements. We reserve the right
to change specifications and/or dimensions without notice. Diagram for guidance purposes only. Comprehensive details of
dimensions, connections, etc. for each model are given on product dimension data sheets available from Fulton.

Flue Outlet

THE COMBUSTION SYSTEM - THE THREE PASS SYSTEM


1 The burner fires down the center.
2 The flame turns and comes back
between the coils to the front.

Control Panel

Fluid Inlet

3 The flame returns down the outside


of the coils and exits out the flue.

Fluid Outlet

On/Off or Full Modulation Burner

The heat transfer innovators.


Fulton Thermal Corporation

972 Centerville Road, Pulaski, NY 13142


Call: (315) 298-5121 Fax: (315) 298-6390

www.fulton.com
ALN-BRO_2013-1218