PNEUMATIC TESTING
EDA
Engineering Design & Analysis Ltd.
J Aumuller, P. Eng.
P Koponyas, M. Eng., P. Eng.
Edmonton, AB Canada
IPEIA
PNEUMATIC TESTING
Overview
IPEIA
PNEUMATIC TESTING
Code Provisions
Codes specify hydrostatic testing as final check of design,
construction & inspection however, not a proof test
Hydrostatic test at 1.3x to 1.5x Design Pressure, MAWP
Hydrotest at 30 F above minimum design metal temperature
[MDMT]
Pneumatic testing may be made in lieu of hydrostatic test; but at
reduced pressure
Pneumatic testing used in lieu of hydrostatic testing when
equipment cannot be safely filled with water
cannot be readily dried where testing liquid cannot be
tolerated
Pneumatic test at 1.1x Design Pressure, MAWP
3
IPEIA
PNEUMATIC TESTING
IPEIA
PNEUMATIC TESTING
IPEIA
PNEUMATIC TESTING
IPEIA
PNEUMATIC TESTING
A Hydro-Pneumatic Failure
No injuries but many sad faces !
IPEIA
PNEUMATIC TESTING
IPEIA
PNEUMATIC TESTING
IPEIA
PNEUMATIC TESTING
10
IPEIA
PNEUMATIC TESTING
Source: www.worksafe.vic.gov.au
11
IPEIA
PNEUMATIC TESTING
12
IPEIA
PNEUMATIC TESTING
13
IPEIA
PNEUMATIC TESTING
Qualitative Differences
Water is not compressible
Air is compressible
Energy storage is large
Pressure change proportional to volume change [P1V1= P2V2]
Bulk modulus, K = 20.6 psi
Air filled balloon pops large, instantaneous energy release
14
IPEIA
PNEUMATIC TESTING
Comparisons
What is the stored energy in 42 NPS pipe, 36 feet
length and pressurized to 7.5 psig?
Pneumatic Test
Hydrostatic Test
W = P dV = P
1 P2
=
V
2 K
= 4.44 lbf - ft
V
dP
K
W = V dP
K 1
K
P2
P1 V1
K 1
W=
P1
K 1
= 294,815 lb f - ft
15
IPEIA
PNEUMATIC TESTING
16
IPEIA
PNEUMATIC TESTING
17
IPEIA
PNEUMATIC TESTING
18
IPEIA
PNEUMATIC TESTING
19
IPEIA
PNEUMATIC TESTING
20
IPEIA
PNEUMATIC TESTING
21
IPEIA
PNEUMATIC TESTING
Damage
Glass failure
TNT
[ft]
Lees
[ft]
653
653
381
363
0.50
239
241
0.70
185
187
NASA
[ft]
UACE
[ft]
275
1,415
Note that NASA methodology aligns with TNT & Lees model for 0.50 limit, for this
specific case [may not be case for other situations]
NASA method is referenced in current jurisdiction guidelines
22
IPEIA
PNEUMATIC TESTING
23
IPEIA
PNEUMATIC TESTING
ABSA guidelines
Avoid pneumatic test if possible
If required, critical safety precautions to be considered
24
IPEIA
PNEUMATIC TESTING
25
IPEIA
PNEUMATIC TESTING