Throughput: 180 tests/hour (Up to 450 tests/hour w/ISE)
Environment-friendly reusable Pyrex cuvette Reagent and sample barcode ID recognition available Optional built-in ISE unit available Specifications Type Desktop fully automated random access analyzer Usage General chemistry as photometric assay Immunology as photometric assay (Latex reagents available) Assay type 1 point end, 2 point end, 1 point rate, 2 point rate and electrolytes Through put 180 tests per hour (Up to 450 tests per hour with ISE) Incubation time Five minutes after applying sample for one reagent assay Five minutes after applying second reagent for two reagents assay Sample type Serum, Plasma and Urine Sample input system Type: Removable tray with sample tube holder on a turntable Barcode sample ID detection with optional barcode reader Capacity: Up to 40 samples (handling of STAT available) Sampling pipette Type: Micro-pipette with liquid level detector Rinsing: Inside and outside with purified water Sampling pump Type: Micro syringe Volume: 2 to 35 ul (increment by 0.1ul) Reagent system Type: Removable tray with reagent bottle holder on a turntable Barcode reagent ID detection with barcode reader Capacity: 40 reagent positions on a tray (Twenty 100ml and twenty 20ml bottle positions) Inventory: Calculation of remaining reagent volume available Cooling: Cooling with Peltier element. (8 to 15 degrees Celsius) Reagent pipette Numbers of pipettors: One Type: Micro-pipette with liquid level detector Rinsing: Inside and outside with purified water Number of reagents: Up to two reagents Inventory: Calculation of remaining reagent volume available Reagent pump Type: Micro syringe Volume: 20 to 400 ul (increment by 1ul) Cuvette system Number of cuvettes 45 cuvettes on reaction line Type: Reusable with onboard washing system Material: Pyrex Volume for measurement: Minimum 180 ul Maximum volume: 500 ul in total Reaction system Type: Direct heating system Temperature: 37 degrees Celsius Detector Method: Direct measurement of absorbance in cuvette Bi-chromatic or Mono-chromatic Wavelength: 8 selectable from 340 nm to 800 nm Light source: Halogen tungsten lamp Stirring system Type: Stick type rotating stirrer Dimensions 770 mm (W) x 620 mm (D) x 505 mm (H) (Analyzer only) Weight 135 Kgs Option ISE unit, Sample Barcode Reader, Liquid Level Sensors
Notes: Specifications subject to change without notice
Details of specifications to be determined based on discussion and agreements of further meetings.
FURUNO ELECTRIC CO., LTD.
System Products Division 2-20, Nishinomiyahama, Nishinomiya-City, 662-0934, Japan Tel: +81 798-33-7555 Fax: +81 798-33-7511 URL: http://www.furuno.co.jp