7.16.

3 Emergency operation
This product is designed according to the latest, technical principles and standards, yet something unforeseen
might still happen. If so, it is possible to electrically restraint the output relays if the power supply of the control
unit is still intact.

When a relay is on forced operation, the system must be controlled to make sure that it is not
overloaded. In this situation, the system will not stop automatically when filled. Funki assume no
liability for any damage that might occur in this connection!

On the bottom plate of the control unit there are 8 small switches (see drawing). If one or more of these are
placed in position ON, the output relay referring to the number on the switch will switch on. See table 1, on
page 50.

output relay
1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

switch No.

ON

OFF 1 2 3 4 5 6 7 8

50

Switch No.. Output relay

1 Drive unit system 1

2 Reception unit system 1

3 Drive unit system 2

4 Reception unit system 2

5 Light/water/external/release unit 1

6 Light/water/external/release unit 2

7 Light/water/external/ 3

8 Alarm

Tabel 1: Table of output relays.