Take into account:

- The design rules for calculations of builded structures


(In The Netherlands: NEN6702 is used)
- The height to be installed
- The windregime where to install
- The situation Builded area Yes/No
- Maximum allowed deflection
- The values for safety:
- General (fg)
- Variable (fv)
- Dynamic (fd)

- Factor Cd (Shape Coefficient) : 0,8


- Weight of Unit: 38 kg
- Projected area: 0,95 m^2
- Natural Frequency pole: <2,4 Hz
120°`0,5°
Example:
Thrust Force at Unit without safety factors at 40 m /s: 730 N
walltickness min 10mm
NOTE:

n70 Pole needs to be at minimum 3 meter long


because of twisting possibillity from the cable.
12

Cable must be properly fixed at the down side pole


to avoid damage caused by twisting of the cable.
(See detail)

When mounted on builded structures:

Use vibration absorbers to prevent sound inside.


60
108
125

detail

R20

Use cable gland


M10 (4x)

Home Energy International B.V. Surface treatment: -

Property of Home Energy International B.V.


Drawing: HE 10 06 003 Rev:
Reproduction or distribution of information in
any form, without written consent of the Minimum Requirements top V100
owner is prohibited!
pole
Product: ENERGY BALL V100
Tolerances (If not specified):
Drawn: HV Date: 19-1-2009
- BREAK SHARP EDGES : 0,2 x 0,2
- Angles: + 0,5 Unit: mm Scale: 1 : 20 Checked: DvW Rev. date:
- General tol: NEN-ISO 2768c
- Surface finish to: ISO 1302 / ISO 468 Size: A4 Weight: Mat: -