PERFORMANCE REQUIREMENTS AND STANDARDS

FOR A SUCCESSFUL EXTERIOR INSULATION AND


FINISH SYSTEMS (EIFS) /
GREEN BUILDING CONFERENCE AT AUD
Mohammed Sanaobar, LBE TC Dubai, 25.06.08

CREATING TOMORROW'S SOLUTIONS


AGENDA

• THE EIFS / ETICS SYSTEM


• WHY EIFS / ETICS?
• MOST IMPORTANT COMPONENTS
• NORMS AND REGULATIONS
• CRITICAL FACTORS
• EOTA WALL
• CASE STUDY CHINA
• COST MODEL

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 1
THE EIFS / ETICS SYSTEM

plaster

base coat

glass fibre mesh

Expanded polystyrene panel EPS

adhesive

substrate

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 2
WHY EIFS / ETICS?
POSSIBILITIES FOR ENERGY SAVING: EIFS MAIN LEVER

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 3
WHY EIFS?

• EIFS has proved to have a superior energy efficiency by


reducing heat transmission by approx 50%
• Improved energy efficiency helps to reduce harmful
emissions typically associated with energy production
such as CO2 emissions and other by-products
• Design Flexibility and Decorative Finishing
• Superior EIFS energy efficiency reduces required air
conditioning equipment capacity and limits the physical
effects of temperature fluctuations hence reducing
structural stress
• EIFS can be applied to new and existing structures.
• EIFS is the ONLY solution for insulating existing
buildings

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 4
MOST IMPORTANT COMPONENTS
REQUIREMENTS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 5
MOST IMPORTANT COMPONENTS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 6
MOST IMPORTANT COMPONENTS
REQUIREMENTS ON THE FRESH AND HARDENED MORTAR

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 7
MOST IMPORTANT COMPONENTS
ADHESIVE AND BASECOAT MORTAR

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 8
MOST IMPORTANT COMPONENTS
MEASUREMENT OF TENSILE ADHESION STRENGTH ON EPS

Force
with 50 N/s
basecoat pull-off test

Cut in the basecoat

EPS (Expanded Polystyrene Panel)

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 9
MOST IMPORTANT COMPONENTS
ADHESIVE AND BASECOAT MORTAR – SEM ANALYSIS

x 50
times

Polymer domain after


film formation
base coat EPS

x 3000
times

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 10
MOST IMPORTANT COMPONENTS
ADHESIVE AND BASECOAT MORTAR – SEM ANALYSIS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 11
MOST IMPORTANT COMPONENT BASECOAT MORTAR
IMPACT RESISTANCE

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 12
TEST AND CONVERSION
JOULE IN CM OR CM IN JOULE g ht
i
we

Min. req..

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 13
MOST IMPORTANT COMPONENT BASECOAT MORTAR
IMPACT TEST WITH 500 GRAM STEAL BALL

e.

P
g.

D
4%

R
1%
RD
P

g.
e.
PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS
Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 14
MOST IMPORTANT COMPONENTS
TOPCOAT

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 15
MOST IMPORTANT COMPONENTS TOPCOAT
CAPILLARY WATER ABSORPTION

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 16
MOST IMPORTANT COMPONENTS
INSULATION PANELS

Construction material Density Thermal conductivity


(kg/m3) (W/m °C)

Concrete 2088 1.21

Hollow brick 1380 0.73

Plaster 2000 1.20

Air gap 1.25 0.28

Polystyrene boards 24.0 0.04

Roof bricks 1400 0.95

Sand 1450 0.38

Cement tiles 2145 1.35

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 17
MOST IMPORTANT COMPONENTS
INSULATION PANELS

EXPANDED EXTRUDED
TECHNICAL MINERALWOOL
POLYSTYRENE POLYSTYRENE
PROPERTIES ( MW )
( EPS ) ( XPS )

The coefficient of heat


0,033 0,028 - 0,031 0,040
conduction“λ”

The coefficient of water


20 - 250 8 - 250 1
vapour resistance ‘’μ’’

Flame class B1 or B2 B1 or B2 Flame proof

Density
3
≥ 14 ≥ 20 8 - 500
(Kg/m )

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 18
MOST IMPORTANT COMPONENTS
FLAMMABILITY STANDARDS CLASSIFICATION AS PER
EN 13501-1: May 2007

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 19
MOST IMPORTANT COMPONENTS
FLAMMABILITY STANDARDS TEST METHODS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 20
MOST IMPORTANT COMPONENTS
DOWEL

• To be applied 24 h after adhesive has


dried.
• 2 – 4 pc/m² typically in Europe
• 10 pc/ m² as per Dubai Municipality
requirements
• Fastening systems such as shot nails,
screwed nails or expansion bolts.
• Minimum fastener penetration: 7cm
for ALC block, 4cm for brick or
concrete

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 21
CRITICAL FACTORS
THERMAL BRIDGES

source ETAG 004 Edition 2004

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 22
CRITICAL FACTORS
HUMIDITY

• Water vapour diffusion has to be


considered in order to prevent the
built up of condensate which can
cause damages.
• In hot an humid climates with AC
a permanent water vapour
pressure difference between
outside and inside air exists.
• High humidity penetrating in the
concrete in combination with high
temperatures can accelerate
carbonation and corrosion of the
reinforcement.

source „WDVS in anderen Klimazonen“ by Dr. Künzel

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 23
NORMS AND REGULATIONS

• The Insulation Requirement by Dubai Municipality (Administrative order


No 77 in 2001)

U value less 0.1 Btu/ °F.ft². h or 0,57 W/(m².K) for walls.

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 24
NORMS AND REGULATIONS
THE MOST IMPORTANT GUIDELINE ETAG 004

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 25
STANDARDS AND NORMS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 26
NEW EOTA RIG
BETTER SERVICE FOR OUR CLIENTS

Two individual walls at the climate


chamber tested at the same time
(appr. 24 tests/year)

Test wall preparation for


the hygro-thermal test

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 27
STANDARDS AND NORMS (EOTA WALL)
(ETAG 004 5.1.3.2.1)

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 28
TESTING THE EFFECTS OF EIFS UNDER PRACTICAL
CONDITIONS IN DIFFERENT CLIMATIC ZONES IN CHINA

50°

Cold & Dry Area


40°
Beijing

30°
Hot Humid Summer
Shanghai
& Cold Winter Area 20°

Tropic Climate
Guangzhou
Area
North

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 29
ONE YEAR MODEL HOUSE PROJECT WITH CHINESE
UNIVERSITIES PROVES EFFECTIVENESS OF EXTERIOR
INSULATION FINISHING SYSTEMS

Aim
Aim
Beijing
Prove
Prove effectiveness
effectiveness of
of EIFS
EIFS toto the
the Chinese
Chinese building
building
北京
industy
industy under
under the
the existing
existing climatic
climatic conditions
conditions
North
Approach
Approach
•• Two
Two identical
identical model
model houses
houses –– one
one with,
with, one
one without
without
Shanghai EIFS
EIFS –– in
in Beijing,
Beijing, Shanghai,
Shanghai, Guangzhou
Guangzhou
上海 •• Cooperation
Cooperation with
with Customers
Customers toto build
build houses
houses
•• Cooperation
Cooperation with
with the
the Universities
Universities Tsing
Tsing Hua,
Hua, Tongji
Tongji
East and
and South
South China
China Science
Science & & Technology
Technology for for data
data
collection
collection and
and interpretation
interpretation
•• Spreading
Spreading message
message in in seminars,
seminars, media,
media, to to
Guangzhou
广州 associations,
associations, government
government etc.
etc.

South Time
Time line
line
Oct.
Oct. 2002
2002 –– Oct.
Oct. 2003
2003

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 30
SAMPLES HOUSES WITH AND WITHOUT EIFS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 31
SAMPLES HOUSES WITH AND WITHOUT EIFS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 32
SAMPLES HOUSES WITH AND WITHOUT EIFS

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 33
TEMPERATURE VARIATIONS INSIDE THE MODEL HOUSES
WITH AND WITHOUT EIFS DURING THE COLD AND HOT
SEASON IN CHINA

32
20
Temperature [degr. C]

18
16 30
14
12 28
10
8 26
6
4 During coldest 24
2 month
0
22
-2
-4
20
-6 During the hottest
-8
-10 18
month
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
time/d time/d

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 34
EIFS ACHIEVE CONSIDERABLE REDUCTION OF ENERGY
USED TO HEAT AND COOL IN THREE DIFFERENT CLIMATIC
ZONES
Average reduction of electricity
consumption in %,
Oct. 2002- Oct. 2003

50

40

30 Winter
20 Summer

10

0
Beijing Shanghai Guangzhou

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 35
COST MODEL
ENERGY SAVING CALCULATION

• Consider a house of 200 m² without EIFS

Media Thickness (m) U value (W/m²k) Thermal


Resistance
Brick wall 0.24 2.29 = 0.24/ 2.29
= 0.104
Normal Plaster 0.015 0.50 = 0.015/0.50
= 0.03

• The Total Thermal Resistance = 0.104+0.03 = 0.17 m².K/W


• Total U value = 1/ 0.17= 5.8823 W/mk
• Heat loss = U * Area * dT( standard temp difference) = 5.8823* 200 * 17 = 20000 W
PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS
Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 36
COST MODEL
ENERGY SAVING CALCULATION

• Consider a house of 200 m² with EIFS

Media Thickness (m) U value (W/m²k) Thermal


Resistance
Brick wall 0.24 2.29 = 0.24/ 2.29
= 0.104
Normal Plaster 0.015 0.50 = 0.015/0.50
=0.03
EIFS 0.15 0.33 = 0.15/ 0.33
= 0.45
• The Total Thermal Resistance = 0.104+0.03 + 0.45 = 0.548 m².K/W
• Total U value = 1/ 0.548 = 1.71 W/m²k
• Heat loss = U * Area * dT( standard temp difference)= 1.71* 200 * 17 = 5821 W
PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS
Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 37
COST MODEL
ENERGY SAVING CALCULATION

• Conclusion: The Energy Saving between the two cases


= 20000- 5821 = 14718 W
• In average you can save between 60-70 % of the heating oil
required.

PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS


Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 38
PERFORMANCE REQUIREMENTS AND STANDARDS FOR EIFS
Mohammed Sanaobar, L-B-E-T/TC Dubai, 25-06-2008, Slide 39