Residential Gas Meter G4

Exact measurement and security

Overview The gas meter UG-G4 is designed for measurement of gas supplied to apartments where maximum consumption of gas is equivalent to 6m3/h of air of density of 1,2 kg/m3. The gas meters can be used for measurement of:

Technical Data Maximum flow rate: Minimum flow rate: Nominal flow rate: Cyclic volume: Max. working pressure: Index max indication Starting flow rate: Weight: Fireproof up to 650C according to EN1359 Qmax = 6 m3/h Qmin = 0,04 m3/h Qn = 4 m3/h V = 1,2 dm3 Pmax = 0,5 bar 99999,999 m3 5 dm3/h ~2 kg up to 0,1 bar

Natural gas City gas Propane-butane gas

Gas meter is equipped with pulse magnet as standard. Pulse transmitter can be added at any time (1 imp = 0,01 m3).
Avarage pressure loss P [mbar]
2.0

Pressure loss curves


Error [%]
3 2 1 0 1.0
1 2

Typical error curves

1.5

Dimensions

-1 -2 -3 0
Qmin

EN 1359 / OIML R31

EG 71/318

0.5

0 0 1 2 3 4 5 6

Flow rate Q (m3/h)

Flow rate Q (m3/h)

1 air 2 natural gas

APATOR METRIX SA Piaskowa 3 83-110 Tczew, Poland tel. +48-58-53 09 200 fax. +48-58-53 09 300 http://www.metrix.pl e-mail: metrix@metrix.pl