Ice Maker
A. Recommended
location for electrical
and plumbing
fixtures.
B. Floor level
1
11 /2"
(29.2 cm) A
34"
(86.4 cm)
Min.
34 1/2" 28 1/2"
(87.6 cm) (72.4 cm)
Max. 3 1/2" 9"
(8.9 cm) (22.9 cm)
24"
B
(60.1 cm)
15"
(38.1 cm)
DRAIN REQUIREMENTS
Drain lines must have a minimum of 5⁄8"
(15.88 mm) inside diameter.
A. Water Pan Drain lines must have a 1" drop per 48" (2.54 cm
drop per 122 cm) of run or 1⁄4" drop per 12"
Drain
(6.35 mm per 30.48 cm) of run and must not have
B. Water Valve low points where water can settle.
A The floor drains must be large enough to
accommodate drainage from all drains.
B The ideal installation has a standpipe with a 1-1⁄2"
7 5/16"
A (18.58 cm) (3.81 cm) to 2" (5.08 cm) PVC drain reducer installed
3 5 /8"
(9.2 cm) directly below the outlet of the drain tube as shown.
B 1" (2.54 cm)
You must maintain a 1" (2.54 cm) air gap between the
drain hose and the standpipe.
23" C It may be desirable to insulate the drain line
(58.4 cm)
5 11/16" D thoroughly up to the drain inlet.
(14.5 cm) 2 7/8" 2" - 1 5/8"
(7.27 cm) A. Drain hose
(5 cm - 3.8 cm)
B. 1" (2.54 cm) air gap
14 5/8" C. PVC drain reducer
(37.2 cm)
D. Center of drain should be 23" (58.4 cm) from front of door,
with or without the ³⁄₄" (1.91 cm) panel on the door. The
drain should also be centered from left to right (7 ⁵⁄₁₆"
[18.58 cm] from either side of the ice maker).
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation Ref. 2313814
our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. 05-16-07