Professional Documents
Culture Documents
Control program format Clear receive buffer after receiving control program Is DNC required DNC settings
Port Number Baud rate Data bits Parity Stop bits Handshake COM2 (or any free COM port) 9600 7 Even 1 Hardware
Standard No Yes
Transmit settings
Transmit directory Wait period at start of transmission Wait period after transmitting program Size of transmit packet Delay period after each packet Wait for XON before transmitting program Drip feed Transmit comments ? Comment start character Comment end character Translation mode for CR Translation mode for LF Program start string Program end string Filter Null Characters Character to transmit at start Character to transmit at end Specify folder to store programs to be sent to machine from PC 10.0 5.0 0 0 No Off Yes ( ) Transmit as CR Transmit as LF
Receive settings
Receive directory Wait period before receiving program Wait period after receiving program Transmit XON before transmitting program Auto compare and save Acknowledgements and errors Translation mode for CR Translation mode for LF Save Program between Start Characters and End Characters Start Program reception after these characters are received End Program reception after these characters are received Acknowledgement / Error message start Acknowledgement / Error message end Ignore control characters other than CR-LF Specify folder to store programs coming from machine 45.0 5.0 No Yes Transmit descriptive messages Ignore Save as CRLF No
%1234 M2 % Yes
Cable connection
If the PC has 9 pin connector
Null modem Full Handshake
PC 9 pin 1 2 3 4 5 6 7 8
CNC 25 pin 8 2 3 20 7 6 4 5
PC 9 pin 1 2 3 4 5 6 7 8
CNC 25 pin 8 2 3 6 7 20 5 4
PC 25 pin 8 2 3 20 7 6 4 5
CNC 25 pin 8 3 2 20 7 6 4 5
PC 25 pin 8 2 3 20 7 6 4 5
CNC 25 pin 8 3 2 6 7 20 5 4