Baruffaldi make servo amplifier (type : DMS08BF) and motor ( type : B5602P-
right & left turret units, at OFC by our engineer , during December 2010. The units
were working properly for few days and later on found to have problems as below :
The right side turret, whenever the m/c is switched on , the display on amplifier
Since this alarm comes immediately after switch on, no further functions are possible
from the turret side. We have requested M/S Sanprem consultants to attend to this
problem & were advised to replace the resolver cable which connects amplifier and
motor ( cable supplied by HMT) . A new resolver cable is being sent from MBX
shortly.But services of M/S Sanprem consultants are required at OFC since this a
Please arrange to inform M/S Sanprem Consultants regarding above problem and
Necessary deputation of their service engineer and confirm the details of his visit , to
TO : JGM (MM)
JGM(RC)