SUMMARY OF SAVINGS A. Electrical - Essential: Sl.No Recommendation Energy Saving Annual Value Investment per Annum of Energy ( Rs.

Lakhs) ( kWh) Savings (Lakh Rs / Annum) Monitor CPDCL power Savings Not voltages during the night Quantified. time for Avoiding High Voltage and change the tap position. Use of High Efficiency 1,60,000 8.67 3.00 Brine Pumps. Improve Cold Insulation 32,800 1.78 2.00 for Brine tanks, Chillers and Pipe lines Correction of MIBK 18,000 0.98 Cooling tower Pump Installation Improve Tail end power Savings Not factor. Quantified. Correction of Hot water 7,600 0.41 0.50 Pump of 10 H.P Installation. Total 2,18,400 11.84 5.50 Pay back Period ( Years)

2 3 4 5 6

<1 1.12

1.20

B. Electrical - Desired: Sl.No Recommendation

1
2

Energy Saving Annual Value Investment per Annum of Energy ( Rs.Lakhs) ( kWh) Savings (Rs / Annum) Modify one Brine Savings Not Compressor for +5OC Quantified. Chilled Water Generation. Replace 200 Watts GLS 26,000 1.41 2.64 Lamps with 70 Watts Sodium Vapor Lamps Total 26,000 1.41 2.64

Pay back Period ( Years)

1.87

SUMMARY OF SAVINGS A. Thermal - Essential: Sl.No Recommendation

1 2 3

Energy Saving per Annum ( MT of Sugar cane Briquettes) Control Excess Air of the 221.00 Boiler Improve Condensate 70.83 Recovery System. Use Moisture Separator Savings Not and reduce steam Quantified. generation pressure to 6.0 kg/cm2 Total 291.83

Annual Value Investment of Energy ( Rs.Lakhs) Savings (Rs.Lakhs / Annum) 8.61 2.00 2.76 3.00

Pay back Period ( Years) <1 1.09

11.37

5.00