Professional Documents
Culture Documents
Sr. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Accepted Description Installation and Commissioning Test Site Data: VSWR measurement, antenna orientation, Antenna type etc. Site Layout 2 Inventory 2 Physical inspection : Installing, cabling and labeling Main power supply to BTS Hardware Commissioning Test : Power units and all cards testing Hardware Commissioning Test: Antenna mapping TRX/sector testing Fans Check 4 All type of redundancy test ( Digital/Power etc) Output Power test Checking of PCM synchro Auto Recovery Testing after PCM link failure BCCH switchover testing All type of External Alarm Testing Testing of battery operation Single BCCH Testing Yes/ No /N/A Comments
1. BTS INVENTORY: INVENTORY NAME CABINET DXU IDM PSU1 PSU2 PSU3 PSU4 DCCU-14 DRU1 DRU2 DRU3 DRU4 PRODUCT NUMBER FAB 620 580/060 BOE 602 21/1 BMG 980 41/2 BMR 910 423/2 BMR 910 423/2 BMR 910 423/2 BMG980344/1 KRC 161 145/1 KRC 161 145/1 SERIAL NUMBER
DRU5 DRU6 FCU (RBS 2964) TMA-CM HEX CLU(RBS 2954) IFB 01
2. BTS SOFTWARE /DATABASE (From OMT) RAM file package Flash file package Flash backup file package
.,
TG NO:
..
4. CELL ARFCN DETAILS SECTOR CELL A CELL B CELL C 5. HANDOVER TEST A to B A to C B to A B to C C to A C to B ARFCN TEST CALL( verified from BSC)
6. SWR TEST (Printout Report to be made available at the Time of AT by Ericsson). SECTOR CELL A CELL B CELL C DX1 DX2
7. EXTERNAL ALARM TEST ALARM SLOGAN DG ON (GS) DG FAILED TO START (GS) MAINS FAIL (GS) HIGH TEMPERATURE (GS) DG FUEL LEVEL LOW LLOP ON DG FAILED TO STOP DOOR ALARM FIRE & SMOKE BATTERY FUSE FAIL RECTIFIER FAIL (GS) LOW BATTERY VOLTAGE (GS) ID 0 1 2 3 4 5 6 8 9 B C D LEVEL 2 2 2 1 2 2 2 1 1 1 1 1 TRIGGER TYPE Closing Closing Closing Closing Closing Closing Breaking Breaking Closing Closing Closing Closing BY SIMULATION ACTUAL
Remarks, if .. ..
IDEA CELLULAR LTD Representative:
ERICSSON INDIA PVT. LTD Representative: ERICSSON INDIA PVT. LTD Circle Lead: IDEA CELLULAR LTD
________________ _
Signature:
________________ _
Date:
_________________
Signature:
Date:
_________________ _ _________________
Signature:
Date:
Manager:
Signature:
Date: