You are on page 1of 11

Nume Client : . . . . . . . . . . . . . . . . . . . . . .

TOTAL
11/19/2011
-15 5.0 7.00 1.000 CM 1.00
T inter. C 20 2. 0.00 25 0.00
h
$ de
calcul
/ L
H sol h
$ de
calcul
/ L
H sol
Lvitral. aprox. exact i fer./usi l Lvitral. aprox. exact i fer./usi
5erete 1 2.50 0.00 0.00 M -15 0.00 0.00 1.038 5erete 2 2.50 0.00 0.00 M -15 0.00 0.00 1.038
fereastra 1 0.00 0.00 T. S,- -15 0.00 0.094 1.200 fereastra 1 0.00 0.00 T. S,- -15 0.00 0.094 1.200
fereastra 2 0.00 0.00 T. S,- -15 0.00 0.094 1.200 fereastra 2 0.00 0.00 T. S,- -15 0.00 0.094 1.200
fereastra 3 0.00 0.00 T. S,- -15 0.00 0.094 1.200 fereastra 3 0.00 0.00 T. S,- -15 0.00 0.094 1.200
usa 0.00 0.00 T. S,- -15 0.00 0.094 1.200 usa 0.00 0.00 T. S,- -15 0.00 0.094 1.200
5erete 3 2.50 0.00 0.00 M -15 0.00 0.00 1.038 5erete 4 2.50 0.00 0.00 M -15 0.00 0.00 1.038
fereastra 1 0.00 0.00 T. S,- -15 0.00 0.094 1.200 fereastra 1 0.00 0.00 T. S,- -15 0.00 0.094 1.200
fereastra 2 0.00 0.00 T. S,- -15 0.00 0.094 1.200 fereastra 2 0.00 0.00 T. S,- -15 0.00 0.094 1.200
usa 0.00 0.00 T. S,- -15 0.00 0.094 1.200 usa 0.00 0.00 T. S,- -15 0.00 0.094 1.200
5erete 5 2.50 0.00 0.00 M -15 0.00 0.00 1.038 5erete 6 2.50 0.00 0.00 M -15 0.00 0.00 1.038
fereastra 0.00 0.00 T. S,- -15 0.00 0.094 1.200 fereastra 0.00 0.00 T. S,- -15 0.00 0.094 1.200
usa 0.00 0.00 T. S,- -15 0.00 0.094 1.200 usa 0.00 0.00 T. S,- -15 0.00 0.094 1.200
5erete 7 2.50 0.00 0.00 S 0.70 20 0.00 1.000 5erete 8 2.50 0.00 0.00 S 0.70 20 0.00 1.000
usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200 usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200
usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200 usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200
5erete 9 2.50 0.00 0.00 S 0.70 18 0.00 1.000 5erete 10 2.50 0.00 0.00 S 0.70 20 0.00 1.000
usa 0.00 0.00 T. S,- 18 0.00 0.094 1.200 usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200
usa 0.00 0.00 T. S,- 18 0.00 0.094 1.200 usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200
5erete 11 2.50 0.00 0.00 S 0.70 20 0.00 1.000 5erete 12 2.50 0.00 0.00 S 0.70 20 0.00 1.000
usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200 usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200
5erete 13 2.50 0.00 0.00 S 0.70 20 0.00 1.000 5erete 14 2.50 0.00 0.00 S 0.70 20 0.00 1.000
usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200 usa 0.00 0.00 T. S,- 20 0.00 0.094 1.200
54/e, 1 0.00 0.00 P1 20 0.00 0.00 1.000 t,;,n 1 0.00 0.00 0.00 0.00 T1 20 0.00 0.00 1.038
podea 2 0.00 P1 20 0.00 0.00 1.000 tavan 2 0.00 0.00 0.00 0.00 T1 20 0.00 1.038
podea 3 0.00 P1 20 0.00 0.00 1.000 tavan 3 0.00 0.00 0.00 0.00 T1 20 0.00 1.038
podea 4 0.00 P1 20 0.00 0.00 1.000 tavan 4 0.00 0.00 0.00 0.00 T1 20 0.00 1.038
podea 5 0.00 P1 20 0.00 0.00 1.000 tavan 5 0.00 0.00 0.00 0.00 T1 20 0.00 1.038
fereastra 1 0.00 0.00 T. S,- -15 0.00 0.094 1.200 1
fereastra 2 0.00 0.00 T. S,- -15 0.00 0.094 1.200 1
AT 0.00 1.20 A usi ext. 0.00 Qi1 0 0.00
Ap 0.00 ms 0.50 n-nr.desch. Qi2 0
Rp 0.00 ns 1.40 Qu 0 L rosturi 0.00 0.00
Abc 0.00 V 3/4 8.55 aer 1.20 0
R bc 0.000 pt. nao nao Cp 1,011 0
Abcj 0.000 0
4n, cim,tic, 4n, e4i,n, in 4c,it,te A/incime, 5inzei /e ,5, fre,tic,
0 Neces,r termic t4t,
m elem.
de
constr.
QT
Aveti mai jos o serie de marimi si valorile lor, conform $R 1907, asa cum le utilizeaza si acest program. O parte provin din pag. Culise, o parte sint rezultatul unor formule de calcul, iar o alta parte sint constante ce pot fi introduse de operator. Atentie sa nu stergeti din greseala
vreo formula. Cei care au cunostinte in domeniu isi pot adapta si mai bine calculele la experienta si nevoile lor, ca si in pagina Culise. ar cei care se pricep mai putin, aveti grija ce date introduceti aici ! Modificati DOAR daca : 1. sinteti sigur pe ceea ce faceti, sau 2. doriti
doar sa vedeti cum afecteaza modificarea unei valori rezultatul final, dupa care dati un "UNDO" = Ctrl+Z.
0.000
0.60 Rm Q$
denumire
element
constructie

Temp
ext. a
peret.
h
$upraf
Totala
Rc Rc
m elem.
de
constr.

$upraf
Totala
1.162
Set,ri gener,e ( 5t. intregu im4-i ) :
denumire
element
constructie
V-V4. C,m.
Temp
ext. a
peret.
h
C4ef. Et, E
destinatie camera 0.00022
/enumire / /estin,tie c,mer,
Punct C,r/in, Est
Ac 16.200
QT*adaosuri
Ao
QT*ad.+Qi
Adaosuri
camere de locuit
beton armat
12.5 polistiren 7 M
1.5567
Tabel Definitii Formule
PODEA izolata inseamna :
Daca intilniti materiale de constructie care nu apar
le puteti scrie mai jos, astfel incit sa le puteti folosi
TAVAN izolat inseamna : Denumire, compozitie, densitate, producator
1
2
3
4
5
6
7
8
9
10
A
B
J
E
F
G
H
1. pe interior, sub tavan, un strat de polistiren expandat (sau vata
minerala) de 3 cm, cu sau fara gips-carton.
D
2. pe exterior, placare cu polistiren. Valabil daca deasupra camerei
aveti o alta incapere in care aveti acces, si careia de fapt ii izolati
podeaua ( pod la casa etc).
C
2. pe exterior, placare cu polistiren expandat (sau vata minerala) de
3 cm, cu sau fara gips-carton. Valabil daca sub camera aveti o alta
incapere in care aveti acces, si careia de fapt ii izolati tavanul ( beci
la casa, sau casa scarilor la bloc etc).
geam termopan, 3 foi de sticla, Low
E, gaz inert, timplarie AL cu rupere
punte termica, lemn stratificat sau
PVC cu 5-6 camere.
geam termopan, 2 foi de sticla, fara
Low E, fara gaz inert, cu timplarie
AL, lemn statificat sau PVC cu 3
camere.
geam termopan, 2 foi de sticla, Low
E, gaz inert, timplarie AL cu rupere
punte termica, lemn stratificat sau
PVC cu 3-4 camere.
ModuI de stabiIire aI graduIui de izoIatie aI peretiIor exteriori sau pIanseeIor -- orientativ Tip constructiv fereastra - orientativ.
geam cu o singura foaie de sticla
obisnuita, timplarie lemn.
Material component

geam cu sticla obisnuita, cu 1 + 2 foi


de sticla, timplarie lemn.
Termopan
bun
Geam dublu 1
geam cu sticla obisnuita, cu 2 foi de
sticla, timplarie lemn.
Grad
izolare
Grosime
( cm )
Geam simplu
Strat izolator
Grosime
( cm )
1. pe interior, un strat de polistiren extrudat de 3 cm grosime.
Rezistenta termica corectata, reaIa ( R c ) =
Pe cei cu adevarat interesati ii invit sa-si calculeze si mai exact rezistenta termica a peretilor sau a
planseelor, cu ajutorul tabelului din dreapta ( col. T-W). De asemenea, pt. cei care nu stiu, aveti si mai
in dreapta o serie de definitii ( K, R, ), precum si o serie de 1ormuIe de caIcuI simpIi1icate din
acest domeniu. Nota : programul face calculele pierderilor de caldura conform formulelor din SR
1907, care sint mult mai "stufoase" !
Termopan slab
Geam dublu 2
Termopan
foarte bun
Pentru PODEA si TAVAN, s-a Iuat in caIcuI o pIaca de beton de 20 cm grosime
+ un eventuaI strat izoIator de 3 cm ( vezi mai jos ).
K R
d R = d/K
cm ! W/mK m2K/W
aer interior 8.000 0.1250
lemn pin i brad perpendicular pe fibre 0.00 0.170 0.0000
plci de ipsos 1100 kg/m3 0.00 0.410 0.0000
vat mineral tip 60 0.00 0.042 0.0000
mortar sau tencuial din ciment 1.00 0.930 0.0108
beton armat 2500 kg/m3 12.50 1.740 0.0718
zidrie din blocuri ceramice tip Porotherm 30 N+F 0.00 0.225 0.0000
zidrie bca tip GBN 35 cu rosturi obinuite 0.00 0.300 0.0000
polistiren celular
7.00 0.044 1.5909
mortar sau tencuial din ciment
2.00 0.930 0.0215
aer exterior 24.000 0.0420
22.50 1.8620
coeficient punti termice : 0.75
rezistenta termica corectata : 1.3965
nivelul gradului de izolare : coI. BH

1
2 ( datele scrise cu rosu pot fi modificate de utilizator ) pereti ext.
3 Lungimea camerei 4.00 m 1.00
4 Latimea camerei 3.00 m
5 naltimea camerei 2.82 m
6 Suprafata camerei 12.00 mp
7 Volumul camerei 33.84 mc
8 Suprafata peretilor exteriori 11.28 mp
9 Suprafata totala a ferestrelor / usilor spre exterior 1.56 mp
10 Coeficientul de transfer termic ( K ) al ferestrelor / usilor spre exterior 1.50 W/mpK
Temperatura interioara 20 C
Temperatura exterioara -21 C
Pierderile de caldura prin peretii propriu-zisi 285.37 W 75%
Pierderile de caldura prin ferestrele / usile spre exterior 95.94 W 25%
Pierderea TOTALA de caIdura : 381.31 W
Pierderea de caldura raportata la volumul camerei 11.27 W / mc
Pierderea de caldura raportata la suprafata camerei 31.78 W / mp
Q = [ 1 / ( R perete din calcul tabel * coeficient punti termice ) ] * (suprafata perete - suprafata
geam) * ( T interioara - T exterioara ) + K geam * suprafata geam * ( T interioara - T exterioara )
Formula simplificata de calcul a pierderilor de caldura printr-un perete cu / fara geam este :
Procent din
total
pierderi de
caldura :
ExempIu de caIcuI aI pierderiIor de caIdura care au Ioc printr-un perete ( sau mai muIti, vezi ceI. W27 -
W28) ca ceI setat mai sus, si corespondentuI acestora in W / m cub si W / m patrat, pt. o camera cu
dimensiuniIe si 1erestreIe de mai jos :
1.10
0.200
0.909
0.250
0.400 2.50
0.667
0.303
4.00
5.00
1.50
3.30
CaIcuIuI exact aI rezistentei termice teoretice / reaIe a unui perete
sau pIanseu, in 1unctie de compozitia Iui :
vezi si Formule
MateriaI component
D L I I N I 1 I I de 8A2A inceput
Intre 2,50 si 3,20 m2K/W pentru pereti exteriori;
Intre 3,60 si 4,20 m2K/W pentru plansee peste ultimul nivel;
Intre 3,00 si 5,00 m2K/W pentru plansee la partea inIerioar;
0.62 m2K/W pentru tmplria exterioar.
Exemple de situatii in care exista punti termice la peretii exteriori :
2* rosturi mai mari intre caramizi, sau "umplute" neglijent : cu goluri etc.
5* finisari neglijente ale izolatiei termice in diferite zone : la ferestre, usi, colturi de zid etc.
8* stilpii de sustinere din beton (portanti) neizolati termic de la colturile cladirii.
10* ETC.
7* izolatie proasta a usilor / ferestrelor in faza de montare : spuma poliuretanica (prea) putina sau prost / neglijent
amplasata (strat prea subtire, cu goluri etc)
AcesLe valorl se dlmlnueaz foarLe mulL in calculul rezlsLen(el c daLorlL prezen(el pun(llor Lermlce
in elemenLele anvelopel
Punti termice = zona / zone in structura (compozitia) unui eIement de constructie care "strica"
omogenitatea Iui, avind o conductivitate termica mai mare, respectiv o rezistenta termica mai mica decit
restuI eIementuIui de constructie dat.
n prezent, valorile propuse in constructii, ale gradului de protectie termic # , pt. asigurarea unui
conIort termic sporit si pt. reducerea risipei de energie termica prin pierderile de caldura sunt mrite mai
mult :
Nivelul de conductivitate termica a unui material este exprimat prin = coef|c|ent de conduct|v|tate term|ca.
Capacitatea unui element de constructie de a se opune transferului de caldura prin masa lui este exprimata de = rez|stenta term|ca
( sau rezistivitatea termica ) a materialului respectiv, si este inversul lui k
c ( notata si R' ) = rez|stenta term|ca corectata, reala, a materialului respectiv = rezistenta termica teoretica (din tabele) x
coeficientul datorat puntilor termice.
Capacitatea de izolare termica a unui element de constructie (de ex. perete exterior, acoperis, pardoseala, etc.) este exprimata de
valoarea k = coef|c|ent de transfer term|c % noLaLa sl D )
= coef|c|entu| de conduct|v|tate term|ca a unui material : reprezinta cantitatea de caldura exprimata in Wh transmisa printr-un
material cu o grosime de 1 m in timp de o ora la o diferenta de 1 grad C intre cele 2 suprafete ale materialului.
9* caramizi cu goluri verticale ... amplasate orizontal, pe directia interior - exterior ( caz "penal" - vezi poza de la
articolul "Asa NU" de pe blog !)
1* boiandruc din beton la ferestre sau usi, la un zid confectionat din materiale de constructie cu o mai buna
rezistenta termica decit betonul (din BCA, de exemplu)
3* perete / zone de perete realizate din resturi ( bucati de BCA, caramida etc.), deci cu rosturi mai dese si mai
mari decit in cazul bucatilor "standard".
4* izolatie termica realizata neglijent. Ex.: placi de polistiren intre care exista spatii pe lateral; zone de vata
minerala "turtita"; placi de polistiren pe sub care poate circula aerul de la o placa la alta etc.
6* materiale de constructie (BCA, caramizi etc) depozitate si / sau folosite mult timp in conditii improprii ( mai ales
umezeala), ceea ce le altereaza proprietatile termoizolante.
k coef|c|entu| de tranfer term|c : reprezinta cantitatea de caldura exprimata in Wh (watti ora) transmisa printr-un m2 de constructie
timp de o ora la o diferenta de 1 grad C intre interior si exterior.
inceput
fluxul Lermlc 1lnL 1exL
( W )
d
c

n
n
unde :
t1 + t2
2
Exemple :
75 + 65
2
50 + 40
2
90 + 70
2
1.3 1.3
25
50

n 1 t$t2
n 1 7S$S
x
6 75/65
n 1 t$t2 t interior
caldura degajata
de un radiator la
temperaturile de
tur / retur t1 / t2 si
la o oarecare
temp. t interior
caldura degajata
de un radiator la
temperaturile de
tur / retur 75 / 65
si la o oarecare
temp. t interior
n = exponent termic, dat de
producatorii de radiatoare, care
difera, pt. fiecare model de
radiator, cu inaltimea lui. Are
valori cuprinse intre 1,25 si 1,37 ,
insa poate fi aproximat linistit la
valoarea de 1,30.
6 t1 / t2
rezlsLenLa
Lermlca
corecLaLa reala
a pereLelul
;

teoret|ca
x
S
coeflclen Lul
de Lransfer
Lermlc
suprafaLa
pereLe
% m2 )
k

0167 rezlsLenLa Lermlca lnsumaLa a sLraLurllor de aer de pe


cele 2 suprafaLe ale pereLelul
teoret|ca
c
x
n

rezlsLenLa
Lermlca LoLala a
pereLelul
LeoreLlca
calculaL cu
valorlle dln
Labele
coeflclenL de corecLle
daLoraL prezenLel
evenLualelor punLl
Lermlce

d groslme
maLerlal
( + 2 + +n ) + 07
lnversul rezlsLenLel
Lermlce corecLaLe
reale

rezlsLenLa
Lermlca
LeoreLlca
81 82 8n rezlsLenLa Lermlca a sLraLulul 1 2 n dln
care e alcaLulL pereLele
I C M D L L s|mp||f|cate
k
x
1 C
dlferenLa de
Lemp lnLerlor
mlnus exLerlor
Deci un radiator, care la temp. de tur / retur de 75 / 65 si la o temp. a camerei t interior de 20 C,
degaja 1000 W, atunci la temp. de tur / retur de 50 / 40 si la o temp. a camerei t interior tot de 20
%C, va degaja doar 406 W, adica aprox. 40 %. De aceea, in acest caz, trebuie ales un radiator cu o
dimensiune mai mare, care la 75/65 sa ofere ( 1000 / 0,4061 ) = 2,463 W, iar la 50 / 40 tot acei
1000 W initiali, necesari camerei.
coeflclenLul de
Lransfer Lermlc
conducLlvl LaLe
Lermlca

teoret|ca

-
-
20
n 1 7S$S 20
-
50
0.4061
25
n 1 90$70
-
20
n 1 S0$0
60
f = un factor de corectie.
Unii producatori de radiatoare
ofera tabele cu valorile
acestui factor de corectie, in
functie de temp. de tur / retur
si t interior, si cu valori ale
n calculate de ei. Un astfel
de tabel foloseste, pt.
calcule, si acest program.
n 1 t$t2
n 1 7S$S

1
1 50/40
0.5
1.
FS S S-M M M-B B FB Pt. peretii exteriori
minim 0.30 0.61 1.01 1.51 2.11 2.71 3.41
maxim 0.60 1.00 1.50 2.10 2.70 3.40 10.00 - valorile scrise cu rosu pot fi modificate.
0.35 0.61 1.01 1.51 2.11 2.71 3.42 --> valoarea propusa ( din tabel ) pt. calculul rezistentei termice,
0.30 0.52 0.86 1.28 1.79 2.30 2.91 --> valoarea de calcul corectata, REALA, obtinuta astfel : valoare
propusa mai sus x coeficientul de ma
Pt. peretii interiori am folosit o valoare de calcul a rezistentei termice corectate Rc de : 0.700
T1 T2 T3 T4 T5 T6 T7
0.30 0.30 1.00 0.30 1.00 0.30 1.00
P1 P2 P3 P4 P5 P6 P7
0.30 0.30 1.00 0.30 1.00 0.30 1.00
2. Adaosul pt. orientarea camerei : un procent cu care se mareste sau se micsoreaza QT = fluxul termic prin transmisie, al intregii camere.
Nord Sud Est Vest N - E N - V S - E S - V
5.00 -5.00 0.00 0.00 5.00 5.00 -5.00 -5.00
3.
T1 T2 T3 T4 T5 T6 T7
20 -11 -11 -5 -5 -15 -15 I II III IV
-12 -15 -18 -21
P1 P2 P3 P4 P5 P6 P7 -8 -11 -13 -16
20 10 10 -15 -15 10 10 11 10 9 8
n cazul unui acoperis izolat termic al podului, temp. de calcul creste, fata de temp. din tabelul de mai sus, cu : 6 grade C.
4. Valorile Ac = adaosul pt. compensarea efectului suprafetelor reci, in functie de Rm = rezistenta termica medie a incaperii = CM*AT*(tint-text) / QT
Rm 0.60 0.70 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.30 2.60 3.00 3.50 4.00 5.00 6.00 8.00 10.00
Ac 16.20 14.25 12.30 11.00 9.70 8.90 8.35 7.75 7.45 7.00 6.60 6.40 6.00 5.75 5.50 5.25 5.00 4.80
5. Viteza de calcul a vintului, in functie de zona eoliana a cladirii si de amplasamentul acesteia, in localitate sau inafara localitatii :
Acestea sint valabile pt. nivelurile 1 - 12 ale cladirilor, si pina la altitudinea de 1.100 m.
v v v v
8.0 16.00 10.0 21.54
5.0 8.55 7.0 13.39
4.5 7.45 6.0 10.90
V 4.0 6.35 4.0 6.35
6.
4 6 8 10 <-- valori SR
0 - 4,5 4,5 - 7 7 - 9 9 - 10. <-- valori program
0.0 0.768 0.645 0.574 0.530 0 - 0,5
1.0 0.490 0.430 0.398 0.377 0,5-1,5
2.0 0.448 0.380 0.347 0.327 1,5 - .
^ valori SR
7. Valorile recomandate pt. nao = numarul de schimburi de aer necesar in incapere in conditii de confort fiziologic :
T.f. bun G.DubIu2
0.094
0.40
2.50
T. SIab
0.060 0.030
0.91
1.10 1.50
T. Bun
5.00
0.25
coeficienti K
tip fereastra
0.20
4.00
0.30
3.30
h (m)
0.67
0.170 0.110 0.140
inafara localitatii
G.SimpIu G.DubIu1
coeficienti R
coeficienti i
Punct Cardinal
Tavan : valoarea temp.
exterioare de calcul %C :
Daca valoarea calculata a Rm difera de valorile de mai sus, se va alege Ac care corespunde valorii imediat inferioare a Rm. De ex., daca Rm este
0,9, se va alege valoarea de la 0,8 ( adica Ac = 12,30 ), iar daca Rm este 4,5, atunci se va alege Ac = 5,75, corespunzatoare lui Rm = 4,00.
H ( m )
M-am hotarit sa dau o tenta de . "open source" acestui program, prezentind moduI de caIcuI si oferind posibiIitatea utiIizatoruIui
care se pricepe sa modifice anumite date utiIizate de "program", pt. obtinerea unor rezuItate adaptate experientei si preferinteIor saIe.
valoarea de calcul a rezistentei
termice ( R c ) pt. PODEA :
0.85
valorile rezist. termice
( R ) pt. fiecare nivel :
valoarea de calcul a rezistentei
termice ( R c ) pt. TAVAN :
valoarea de calcul a rezistentei
termice ( R c ) pt. peretii exteriori :
Coeficientul general care ia in calcul
existenta puntilor termice din pereti;
scade valoarea reala a rezistentei
termice calculate.
coeficienti *
clasificarea gradului de izolare :
Temperaturile exterioare de calcul pt. tavan cu pod, izolat sau neizolat, si pt. podea cu beci, in functie de zona climatica setata :
Podea : valoarea temp.
exterioare de calcul %C :
Zona
eoliana
Rezistenta termica specifica a benzii de contur, Rbc, pt. o grosime a fundatiei de 45 cm, in functie de adincimea de ingropare a pardoselii ( h ) si de
adincimea pinzei de apa freatica ( H ). Folosita la calcularea Qs = pierderile de caldura prin sol.
ona cIimatica setata
Temp. ext. aferenta zonei
- vaIoriIe scrise cu rosu pot fi modificate ! -
Date referitoare la izolatia peretilor exteriori si interiori, a tavanului si podelei, precum si a suprafetelor vitrate : valorile rezistentei termice dupa care se face
clasificarea gradului de izolatie a peretilor exteriori, a tavanului, a podelei si a suprafetelor vitrate, precum si valorile de calcul pt. fiecare treapta, folosite pt.
calcularea pierderilor de caldura. Pt. geamuri, valorile coeficientul de infiltratie " i ".
Temp. in pod neizolat
Temp. sol/beci NEincalzit
in localitate
8. Valorile unor constante, utilizate de program :
CM E
1.00
9.
%
10. O harta a Romaniei, cu impartirea pe zone CLMATCE :

- 12 C - 15 C - 18 C - 21 C
cu verde = zona cu galben = zona cu albastru = zona cu maro = zona V
11. De asemenea, o harta cu impartirea Romaniei pe zone EOLENE :
m tavan Notare m per. ext. m podea
nao*Vol. = 0,007*Nr. Persoane
Bineinteles, valoarea implicita este zero, insa o puteti modifica aici :
Valoare
"Factorul de supradimensionare" = o nascocire pur personala, adresata celor care NU se pot abtine sa nu supradimensioneze radiatoarele si care, oricit de
precis ar face calculele, se tot intreaba "N-o fi prea putin ?" :) . Reprezinta procentul ( % ) cu care se doreste marirea necesarului termic al fiecarei camere, fata
de valoarea rezultata din calcule facute de acest program.
m per. int.

m geam
scoli, crese, spitale
0.00022
0.00033
0.00028
nao (m3/h)/m4 destinatia incaperii nao (m3/s)/m3
camere de locuit
bucatarii
bai
0.792
1.190
1.000

You might also like