Professional Documents
Culture Documents
40 - O9400R Topology and Protection Schemes
40 - O9400R Topology and Protection Schemes
Page 1of 9
White Paper
Add/Drop Capacity:
TM = 252 E1 (Limiting factor is STM-4 capacity); ADM = 378 E1 (Limiting factor is the add/drop capacity of the 63 x 6 E1 cards.)
Advantages:
A simple, two (2) fiber layout
Cost of Advantages:
No protection against a fiber cut and/or optical circuit pack failure
Page 2 of 9
White Paper
TM
Protection Section/ Line
ADM
Protection Section/ Line
ADM
Protection Section/ Line
ADM
Protection Section/ Line
TM
A
Working Line
2:1 select
B
Protection Line
Add/Drop Capacity:
TM = 252 E1s with MSP protection (Limiting factor is STM-4 capacity); ADM = 378 E1s with MSP protection (Limiting factor is the add/drop capacity of the 63 x 6 E1 cards.)
Advantages:
All tributary traffic is protected against a fiber cut and/or optical circuit pack failure
Cost of Advantages:
Four (4) fibers are required. Maximum 252 E1s capacity at head ends (TMs) NOTE: To achieve the best protection schemes possible, the working fibers shall take different routes in different fiber bundles Page 3 of 9
White Paper
Add/Drop Capacity:
252 E1s with SNCP/UPSR protection (Limiting factor is the bandwidth of the STM-4 aggregate line.)
Advantages:
Two (2) fibers only; well protected against a fiber cut and optical circuit pack failure.
Cost of Advantages:
Ring topology is a must NOTE: To achieve the best protection schemes possible, the working fibers shall take different routes in different fiber bundles
Page 4 of 9
White Paper
ADM
East West
POTS SW4
ADM
STM- 4
ADM
POTS SW4
West
East
ADM
252E1
Add/Drop Capacity:
378 E1s without protection (Limiting factor is the number of E1 cards on O9400R)
Advantages:
Two (2) fibers only; maximum number of E1s is 252
Cost of Advantages:
Ring topology is a must. Half of the traffic will be affected when fiber cut.
Page 5 of 9
White Paper
Add/Drop Capacity:
63 to 378 E1s (Limiting factor is the number of E1 cards on O9400R)
Advantages:
Two fibers only; adding/dropping more than 252 E1s per node
Cost of Advantages:
Ring topology is a must. Half of the traffic without protection will be affected when a fiber is cut.
NOTE: To achieve the best protection schemes possible, the working fibers shall take different routes in different fiber bundles
Page 6 of 9
White Paper
Configuration 6: Ring Topology with Both MSP (1+1) and SNCP/UPSR Protection
This configuration is useful to clients who need thorough protection against double fiber cuts and optical circuit pack failure.
0 0 1 1
O9400R ADM
0 0 1 1
O9400R ADM
0 0 1 1
0 0 1 1
0 0 1 1
Add/Drop Capacity:
252 E1s with double protection (Limiting factor is the bandwidth of the STM-4 aggregate line.)
Advantages:
Double protection is provided by SNCP/UPSR and MSP
Cost of Advantages:
Ring topology is a must; four (4) fibers are necessary
NOTE: To achieve the best protection schemes possible, the working fibers shall take different routes in different fiber bundles
Page 7 of 9
White Paper
SDH/SONET backbone
Loo iNM p S
O9400-R O9400- S
0 0 1 1 0 0 1 1
O9400- S
O9400- S
0 0 1 1
0 0 1 1
0 0 1 1
O9100
E1/ T1 E3/ T3 Etherne t
O9400- S
0 0 1 1 00 11
O9400-R
O9100 O9400-R
0 0 1 1
AM342 0
E1/T1
E1/T1
AM344 0
E1/T1
E3/T3
E1/T1
V4200-9
V4200-28
C5500
Add/Drop Capacity:
252 E1s with SNCP/UPSR protection (Limiting factor is the bandwidth of the STM-4 aggregate line.)
Advantages:
All tributary traffic is protected against a fiber cut and optical circuit pack failure.
Cost of Advantages:
Two (2) fibers are required for each ring
NOTE: To achieve the best protection schemes possible, the working fibers shall take different routes in different fiber bundles
Page 8 of 9
White Paper
Add/Drop Capacity:
252 E1s with SNCP/UPSR protection (Limiting factor is the bandwidth of the STM-4 aggregate line.)
Advantages:
All tributary traffic is protected against a fiber cut and optical circuit pack failure.
Cost of Advantages:
Ten (10) fibers are required
NOTE: To achieve the best protection schemes possible, the working fibers shall take different routes in different fiber bundles
Page 9 of 9