You are on page 1of 2

ZAMIL STEEL BUILDINGS DESIGN MANUAL

PEB DIVISION

4. Main framing design

4.6. Standard Anchor Bolts

DM 03.10.00

4-67

ZAMIL STEEL BUILDINGS DESIGN MANUAL


PEB DIVISION

4. Main framing design

Design of Anchor Bolts (Conforming to ASTM A-36 Steel) Design for pure Tension Allowable Tensile Stress Ft = 0.33 Fu Design for Shear Allowable Shear Stress Fv = 0.17 Fu Design for Tension combined with shear Allowable Tensile Stress Ft = 17.94 -1.8*fv < 13.8kN/Cm2 Embedment Length

Allowable Bond Stress u (kN/cm2) :

u=

0.16 f c db

0.138 kN/cm 2

Where, db= diameter of bolt in cm Required Embedment Length Le:

Le =

T ud b

Where, T is maximum tension in bolt (in kN)

DM 03.10.00

4-68