You are on page 1of 10

VDS103-M Modbus -

VDS103-M
Modbus RTU to Modbus TCP Gateway

UserGuide

Version: 1.2.0
Date: 2011-2-13

VDS103-M Modbus -

Cayee Cayee

/
:




I/O
USB


: +852-3590-9266~69
: +852-3590-3595

http://www.cayee.com

http://www.cayee.com/contact.htm

VDS103-M Modbus -

1.

................................................................................................................................................ 4
1.1 ................................................................................................................................................. 4
1.2 ...................................................................................................................................... 4
1.3 .......................................................................................................................................... 5

2.

Specifications ........................................................................................................................................ 6

3.Configuration ............................................................................................................................................. 7
3.1 Device Management and Searching .............................................................................................. 7
3.2 Configuration ................................................................................................................................... 7
3.2.1 (System status).................................................................................................... 7
3.2.2 (Common Settings) .............................................................................................. 8
3.2.3 TCP/IP (TCP/IP Settings) ............................................................................................ 8
3.2.4 Modbus (Modbus Settings) ........................................................................... 9
3.2.5 (Password modification) ....................................................................................... 10
3.2.6 (System rebooting) ....................................................................................... 10

VDS103-M Modbus -

1.
1.1
Modbus RTU/ASCII
Modbus RTU/ASCII
Modbus RTU/ASCII
Modbus RTU/ASCII

Modbus TCP Modbus RTU/ASCII Modbus RTU/ASCII


TCP/IP Modbus TCP Modbus RTU/ASCII
Cayee VDS103-M Modbus Modbus TCP Modbus RTU/ASCII
Modbus TCP RS232/RS485/422 Modbus RTU/ASCII

1.2

32

10/100M

15 KV ESD1.5KV

7~35V DCTerminalPower Jack

Modbus

VDS103-M Modbus -

1.3

PLC

VDS103-M Modbus -

2. Specifications
Hardware
CPU

32 bit ARM7

RAM

8M

Flash

4M

LAN

10/100 auto-negotiation, Build-in surge protection

Serial port

Power
Dimension
Temperature

Interface

RS-485

Baud rate

110 ~ 115200 bps

Parity

NoneEvenOddSpaceMark

Date bits

5678

Stop bit(s)

11.52

Flow Control

NoneXON/XOFFCTS/RTS

Voltage

7 ~ 35 VDC

Consumption

200mA @ 9VDC(max.)

90x52x21 mm (L x W x H)
Operating

-20 ~ 60 C

Storage

-40~85 C

Software
Modbus/TCP Slave to Modbus/RTU Slave
Modbus
Mode

Modbus/RTU Master to Modbus/TCP Master


Modbus/TCP Slave to Modbus/ASCII Slave
Modbus/ASCII Master to Modbus/TCP Master

Configuation

Windows Utility and internal web page

VDS103-M Modbus -

3.Configuration
3.1 Device Management and Searching
Open the device management utility. It will search the local network automatically, then find out
all the VDS103-M(s).

3.2 Configuration
You can access the web page of VDS103-M by its IP address, then do configure according to
your requirement.
3.2.1 (System status)

We can see the current operating status in the (System status) page.

VDS103-M Modbus -

3.2.2 (Common Settings)

In the (Common settings) page, we can set the device name, the CPU frequency and
the system automatically rebooting cycle.

Items

Translation

Device Name

CPU

CPU Frequency

()

Automatically system rebooting

<0 >

cycle(minutes)
<0 means never reboot>

Submit

3.2.3 TCP/IP (TCP/IP Settings)

Remarks

VDS103-M Modbus -
Items

Translations

IP

IP Address

Sub mask

IP

Gateway IP Address

Submit

Remarks

3.2.4 Modbus (Modbus Settings)

Items

Translations

Remarks

Operating Mode

Optional items from top to bottom:


Modbus/TCP slave to Modbus/RTU slave
Modbus/RTU Master to Modbus/TCP Master
Modbus/TCP Slave to Modbus/ASCII Slave
Modbus/ASCII Master to Modbus/TCP Master

Device initialization delay

Character timeout

Data package timeout

TCP

TCP Slave Setting

Enable the exception handling

Serial baud rate

Serial Data bits

Serial parity

VDS103-M Modbus -

Serial Stop bit(s)

Serial flow control

submit

3.2.5 (Password modification)

Items

Translations

New password

Retype new password

Submit

Remarks

3.2.6 (System rebooting)

Items

Translations

Rebooting confirmation

Confirm

Remarks