You are on page 1of 2

Water Flow sensor

Water flow sensor consists of a plastic valve body, a water rotor, and a hall-effect sensor. When water flows through the rotor, rotor rolls. Its speed changes with different rate of flow. The hall-effect sensor outputs the corresponding pulse Signal.

Wiring diagram Specification


Working voltage Maximum current Weight External diameters (Inflow and outflow) Flow rate range Operating temperature Operating humidity Operating pressure Store temperature Store humidity 130 L/min 5V-24V 15 mADC 5V 43 g 20mm

The external diameter of thread the connections use is 1.4mm.

080 35%90%RH under 1.2Mpa -25+80 25%90%RH

Page 1 of 2

7/5/2010

Output Table
Pulse frequency (Hz) in Horizontal Test= 7.5Q, Q is flow rate in L/min. (Results in +/- 3% range)

Output pulse high level Output pulse low level Precision Output signal duty cycle

Signal voltage >4.5 V( input DC 5 V) Signal voltage <0.5V( input DC 5V) 3% (Flow rate from 1L/min to 10L/min) 40%60%

Revision History Rev.


1.0 2.0

Descriptions
public release 1.0 public release 1.0

Release date
31.05.2010 05.07.2010

Page 2 of 2

7/5/2010