Professional Documents
Culture Documents
Is 6403 Code of Practice For Determination of Breaking Capac.182133143
Is 6403 Code of Practice For Determination of Breaking Capac.182133143
Indian Standard
CODE OF PRACTICE FOR DETERMINATION OF BREAKING CAPACITY OF SHALLOW FOUNDATIONS (
First Revision)
UK
624.151.5:624.131.52
:006.76
MANAK BHAVAN,
NEW DELHI
Gr 4
November 1981
IS 6403:1981
Indian Standard
CODE OF PRACTICE FOR DETERMINATION OF BREAKING CAPACITY OF SHALLOW FOUNDATIONS (
Foundation
Chairman PnoF DXNESH MOHAN Members DE R. IL BHAND~RI CEXXF EN QXNEER S rim S. GUHA ( .Mmrndt ) SHRI M. G. DLNDAVATE SIiRI N. C. DUGQAL ( Alfematc DB R. K. DA8 GUPTA ADDITIONAL CBIEr ENOINEEE SHIU A. G. DAETIDMZ SERX V. C. DEBEPANDE DIRECTOR ( CSMRS ) DLCPUTY131 RECTOB CSMRS ( SHRI A. H. DIVANJI Central Building Roorkec Calcutta Port Trust, Research Calcutta Institute ( CSIR )
First Revision)
Sectional Committee,
Reprinting Central Building Roorkee Research Insti! ute ( CSIR ),
Engineering
BDC 43
The Concrete Association of India, Bombay ) Simplex concrete Piles ( India ) Pvt Ltd, Calcutta ( Af@mat# ) In personal capacity ( 5 Hungerfard Road, 121 Hungerford Stwrt, Calcutta ) The Pressure Piling Co ( I ) Pvt Ltd, Bombay Central Water Commission, New Delhi ) ( Afhrndt ) Asia Foundations and Construction Co Pvt Ltd, Bombay
Srm~A. N. JANQLE ( Alternate) DR JAIJDItUI NARAm Indian Gcotechnic Society, New Delhi Prtor SWAMI SARAN ( Akmafc ) SHRI G. S. JLIN G. S. Jain & Associates, Roorkee SHIt~ ASROX KUmAR JAIN ( Alt.rrrate ) JOINT DIRECTOR ( D ) National Buildings Organisatio,n, New Delbf SHRI SUNIL BEEY ( Alternate ) JO~STM ~DIREOTOR REBEAXCH Ministry of Railways ( RDSO ) JOINT DIRTCCTOB RWIEAROE ( B & S ) ( Altwnatt )
OF INDIAN STANDARDS BUREAU This publication is protected under the Indian Cop~ight Act ( XIV of 1957 ) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Act.
1
Jrom piJAI~ I ,i4tmbers
Contlnutd
Represmlin~ Indian Irrstitutc of Tec}mokrgy, Bombay M, N. Dastur & Co Pvt Ltd, Calcutta Public Works Department, Chandigarh Administr*-tion, Charv+!garh Central Warchous,ng Corporation, New Dclhi Machcnzics Limited, Bombay Engineers India Limited, New Delhi
-), IJtf,4 P. M~,rllust <,,,<! \. 1+, ,MATHCR >IIEI ~. ~. D. k[UNSr St+N1 ,M. lYENo Ai2 ( Alternate ) lingincer-in-Chief s Branch, Army Headquarters, ]+11[, ohlBIR Sl~OK New Delhi MAJ H. K. BRUTANI ( A!t.rnate ) The Hindustan Construction Company Limited, SIII~[ f{. K, PANTHAKY Bombay SHrzI V. M. MLDQm ( Af(crnatc ) Ccmindia Co i.tri, Bombay :iHR] M. R. PUXJA SR~l S. MUKIIRRJEE ( Afftrrratt ) The Braithwaite Burn & Jcswp Construction Co Ltd, S}{R] ~. E. V. ~A13HVAN Calcutta Vijayanagar Steel Plant ( St.rl Authority of India ), %I,i[ A. .A. IIAJw New Delhi Clniv=rsityO( R.oorkee,Roorkee P p!c, >F (;,,,4L ~ANJAN Gammon India Limited, Bombay Slit+[ 1. Y. !Y!:5BAFiAo >t{tt1 S. A, RrJnul ( ,4/twmrtc ) Bok.ar~ka~~el Plant ( Steel Authority of India ), \ u RTY. V. NArtASISS~A RACI !)11 \. V. S. RAO iNagadi Consultants Pvt Ltd, Nrw Delhi siIni AHJUN RJJHSI~,; NANI Cement Corporation of India. New Delhi SHR[ ~. S, SItIVA9TAVA ( Affernate ) 1)R A. SAKGLTNAN College of Engineering, Guindy S!{BL S. BOrIMtNATnAN ( Af/trrrate I S,IRI K, R. SAXENA Public Works Department, Government of Andhra Pradesh, Hydcrabad [Jnitcd Technical Consultants Pvt Ltd, Ncw Delhi I)R S. P SHRIVASTAVA r)~ R KAPUR ( ,4ffernafe ) S[{]{l .~. slVA. >UltU ?vLnistry of Shipping and Transport, New Delhi >11Rr 1). V. SIKKA [ Aftwnate ) New Delhi Central Public Works Department, ENGINEER < .7r~[tl,N,rk:~ul~r3 ( DWIIJNS )
EXECIITIVW I? NoIN1713R DIVJTONS ) V ( Af/wnaft ) .HI{I hf D. TAM DEKAFt [)R ,4. VA HADARAJAN [)({ R. KANIBAJ ( Alternate ) ~Hi{l G. RAMAN, Director ( Civ Engg )
Ncw Delhi
Secretnry S~Rt K. M. MATIII-R Deputy Dlrcc!or ( Civ Engg ), 1s1 ( Confinad on page 16)
IS 6403:1981
Indian Standard
CODE OF PMCTICE FOR DETERhf~ATION OF BREAKING CAPACITY OF SHALLOW FOUNDATIONS
( First Revision)
O.
FOREWORD
0.1 This Indian Standard ( First Revision ) was adopted by the Indian Standards Institution on 30 January 1981, after the draft finalized by the Foundation Engineering Sectional Committee had been approved by the
Civil Engineering Division Covncil.
0.2 The bearing capacity of foundations is needed for dimensioning the Several methods are available for the foundation for any structure. determination of bearing capacity of shallow foundations anti this standard gives some of the methods which are commonly used for the Comparison of the results shows that when each of the various purpose. methods is applied to different problems no one method consistently gives higher or lower values of allowable bearing pressure. The designer must therefore regard the methods as aids to design which cannot replace the critical role of engineering judgement.
0.2.1 This standard was first published in 1971. The principal modifications made in this revision are: (a) keeping its terminology in line with that of other related Indian Standards, (b) giving generalized equations for calculation of ultimate bearing capacity, (c) including cone penetration methods and (d) deleting adjustment for fine sand and silt.
requirement of of <irciding whether a particular 0.3 For the purpose this stmdard is complied with, the final value, observed or calculated, expressing the result of a test or anaiysis, shall be rounded off in accordance with IS: 2-1960*. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.
q Rules for rounding off numerical values ( reci$td ).
IS 6403:1981 1. SCOPE 1.1 This standard covers the procedure for determining the ultimate bearing capacity and allowable bearing pressure of shallow foundations based on shear and allowable settlement criteria. 2. TERMINOLOGY 2.0 For apply. the purpose Relating
of
of this
standard,
the following
definitions
shall
2.1 Tersrss
to Bearing
loading
2.1.2 lrltimatc Bearing Capacity The irltensity of loading at the base of the foundation which would cause sitear failure of the soil support. of loading that the 2.1.3 Safe Bra ring Capacity Maxirnunl intensity foundation will safely carry without the risk of shear failure of soil irrespective of any sert!ement that may occur.
settlement 2.1.4 Safe B~aring Preswre or Net Soil Pressure for spectjird The iiltensity of )oading that will cause a permissible settlement or specified settlement of the structure.
2.1.5 Allowable Bearin~ Capactty The net intensity of loading which the found ati{~rl will carry without undergoing settlement in excess of rhe under consideration but not exceeding permissible value for the structure net safe bearing capacity. 2.2 General Terms
2.2.1 Dmsip Index ( Relative Density ) The ratio of the difference between the void ratios of cohesionless soil in the loosest state and any given state to the difference between its void ratios at the loosest and
densest states.
2.2.2 Efective Surcharge at the Base Level of Foundation The intensity computed assuming of vertical pressure at the base level of foundation, total unit weight for the portion of soil above the water table and submerged unit weight for the portion below the water table. 2.2.3 Footing A structure constructed concrete under the base of a wall or column ing the load over a larger area. in brickwork, masonry or for the purpose of distributwhich is in direct contact
2.2.4 Foundation That part of a structure with soil and transmits loads into it. 4
IS 6403:1981 2.2.5 Shallow Foundation A foundation whose width is greater than its depth. The shearing resistance of the soil in the sides of the foundation is generally neglected. 3. SYMBOLS 3.1 For the purpose of this code and unless otherwise defined in the text, the following letter symbols shall have the meaning indicated against each: A = Area of footing in cms
A = Effective
in cmz B = Width of strip footing, width of footing, side of square footing, diameter of circular footing in cm width of footing in kgf/cms cohesion cohesion of the top layer in in cm b= c= Half of B Cohesion Undrained kgf/cm*
area of footing
B = Effective
q -
clay layer
en = Eccentricity cm CL = H=
ic, ia,
iy =
Xa =
Depth factor ( varies linearly from 1 for depth Dt = O to 133 for depth Dr = B )
L . Length of footing in cm L = Effective length of footing in cm NX., ~., Na, .iVa, .Ny, Ny Corrected = Bearing 5 standard capacity penetration value factors
IS 6403:1981 N~ =- tan ( tr14 i- d]2 ) g = Effective surcharge at the base level of foundation in kgf/cms qa e Net soil pressure for a specified settlement of 25 mm in kg f/cm* 90 =
qu = q~ =
Static cone
penetration
resistance
in kgf/ on on
Cms
Net ultimate bearing capacity general shear failure in kgf/cmz
based based
Net ultimate bearing capacity local shear failure in kgf/cms Relative ~a~l;ection density of soil factor for location
R u W =
of
water
fc, $a, $y = Shape factors a = Inclination of the load degrees # == Angle of degrees shearing
to
in in
resistance
of foundation
soil kgf/cms
4.1 Sufficient number of undisturbed samples, about 40 to 100 mm in diameter or more or block samples should be obtained, where possible. are for the determination of field density of soil and These samples
conducting tests for determining the relevant shear and parameters of the soil. Tests on soils shouId be conducted with relevant parts of IS : 2720*. 4.z Position and fluctuation of water table Reference may be made to 1S : 1892-1979t guidance regarding investigations and collection consolidation in accordance
5. ULTIMATE
NET
BEARING
CAPACITY
5.0 General types of faihtre of soil support beneath the Three foundations have been recognized, depending upon the deformations associated with the load and the extent of development of failure surface. ..
*Me[hod. of test for soils. Kbdc of practice for subsurface investigations for foundations ( ,fi,II r.oi~ion ). ~Code of practice for chin-walled tube sampling of soih ( fird rmision ).
IS 6403:1981 They are: a) general shear failure, b) local shear failure and c) punching shear. The choice of which method of analysis is best suited in a given situation is difficult to make, because only limited test data are available on full sized tlxmdations to verify the reliability of the computed bearing capacity. However, guidelines given in relevant clauses may be Wherever possible bearing capacity calculations used for guidance. shall be made on the basis of shear strengtk parameters # and c obtained or from appropriate shear tests [ sw IS :2720 ( Parts XI and XIII)*] from plate load test results as given in IS: M@N81t Oi from static cone peuetratiou resistance ge obtained from static cone penetration test as given in IS : 4968( Part 111 )-1976$.
5.0.1
Effect of Eccentricity
a) Single Eccentricity If the load has an eccentricity e, with respect to the centroid of the foundation in only one direction, then the dimension of the footing in the direction of eccentricity ehall be reduced by a length equal to 2 t. The modi%d dimension shall be used in the bearing capacity equation and m determining the effective area of the footing in resisting the load. m and en ) b) Double ficentrici~ If the load has double eccentricity wit h respect to the centroid of the footing then the effective dimensions of the fating to be used in determining the bearing capacity as well as in computing the effective area of the footing
in resisting the load shall be determined L=L-2u= as given below:
5.1.1 The folIowing formulz shall be used for calculating bearing capacity in the case of strip footings: a) In b) In case case of general shear failure
qa = cJVe + q ( .Na 1 ) +
+BY ~y
of local shear failure ga = # c~e + g ( Na j ByWy 1 ) -i-
Na, Ng,
from
Table 1.
q Methods of testfor soils: Part X1 Determination of shearstrength parametersof speciroen tested in unconsolidated undrained triaxiat comprcmion without the mcuuremeot of pore water pressure, and Part XIII Direct shear test ( Jrrt rmi~n ). q
tMcthod $Method
1.
(Jr$l rm,ion).
IS 6403:
1981
(Dc~ees)
0
000
0,45
1,22 2.65
10
15
8.35
1098
247
394
20 25 30
35
14:83
2072
3014
4612
40 45 50
valuet of Ne, Nq and Ny, calculate # NOTIt For obtaining Read Nc, Nq, and NY. from the Tahlc eorrrspnnding to the (0671 an+j. of + 1nwcad Of + which are values of Nc, Nq, Ny respectively.
value
5.1.2 The ultimate net bearing capacity obtained in 5.1.1 for strip the shape of the footing, footing shall be modified to take into account, inclinatiori of loading, depth of embedment and effect of water table. The modified bearing capacity formula are given as under: a) [n case of general shear failure qd } b) In case of local shear ~
failure 5.1.2.1 gd ~
BYNy~ydyiy
W
1 ) Jadaia
= # tNc
+
ICdcic + q( Na ~ ByNysydyiy W
TABLE 2
sKAPlr Or ~ABE
SHAPE
FACTORS
SHAPB
%
O
~.A.A #c Continuous Rcctanr,lc Square Circle Uie L?as the diameter strip I +02 I 00 B/L 13 13 in the bearing
capacity
FAOTOB $q JY
I.00
l+ O2B/L I 2 1.2 formula.
100
1-0-4 B/L
08
06
5.1.2.2
The
is to be applied
with propar
5.1.2.3
The inclination
C= =(-%J =(l--;Y
5.1.2.4 E/Jbct of water tabla
a) If the water table .is likely to permanently depth of ( Dr + B ) beneath the ground footing then W == 1.
at a depth D! or likely to rise to the b) If the water table is located base of the footing or above then the value of W shall be taken as 05.
c) If the water table is likely to permanently got located at depth D! < Dw < ( Dr -!- B ), then the value of W be obtained by
llnear interpolation.
5.2 Cohesionless
shall be calculated
bearing
capacity
5.2.1 Ba~cd on Relative Density The formukz given in %1.1 and shall be used, together with relevant shear strength parameter.
a guide
5.2.1.1 The relative density to de[crrnine the method 3 METHOD
OF
5.1.2
as
as given in Table
of analysis.
3 shall be used
TABLE
SL
ILE.LATIVE DENSITY
No. i)
( DEXa[TY
IxTmE
ii)
Lowe
iii)
20 to 70 percent
Medium
IS 6403:
1981
Bated an S[andard Penetration Resistance Value The standard 5.2.2 penetration resistance shall be determined as per IS : 213! -1981 q at a number of selected points at intervals of 75 cm in the vertical direction c;r change of strata if it takes place earlier and the average value beneath each point shall be determined between the level of the base of the footing and the de~th equal to 15 to 2 times the width of foundation. In computing the average any individual value more than 50 percent greater than the average shall be neglected, but the values for all loose seams shall be included. 5.2.2.1 The ultimate net bearing capacity shall be calculated from fo]lowing formula ( covering effect of other factors as mentioned in 5.1.2 ):
gd=$(~q 1 )
~Qdqia + ~ ByNyqdyiy
Where # may be read from Fig. 1, Ny, ,Vq may be read from Table 1, Sa, dQ, iq, syj dy, iy, and W may be obtained as in 5.1. 5.2.3 Method Based on Static Cone Penetration Test The static cone point resistance gc shall be determined as per IS : 4968 ( Part 111 )- 1976t at The observed number of selected points at intervals of 10 to 15 cm. values shall be corrected for the dead weight of sounding rods. Then the average value at each one of the location shall be determined between the level of the base of the footing and the depth equal to 1~ to 2 times the width of the footing. The average of the static cone point resistance values shall be determined for each one of the location and minimum of the average values shall be used in the design. The uitimate bearing capacity of shallow strip footings on cohesionless soil deposits shall be determined from Fig. 2. 5.3 Cohesive Soil ( when + = O )
5.3.1.1 The net ultimate bearing capacity immediately after const~ii..tl(;,, on fairly saturated homogeneous cohesive soils shall be calculated kmn following formula:
qd =
where
cNe
SC
dc i=
penetration
test
: firuxruriltin ).
IS 6403:1981
I .
q \ 0
N
u u z ; i% :
>0
o m o u _- \
-i
z
0 a 0 m
F-
_____ ,1
0 -a
~+
i __.._] I
..+. -.. I
28 30 32
OF
1
3fi 36 38 60
INTERNLL FRICTION, RELATIONSHIP
1~. ,
7
BETWEEN
_
bb (+6
L2
ANGLE
C$ (DEGREES) ~ AND
N
FIG. 1
11
IS 6403:
1981
1
8 tj c-m
FIG. 2 CHART FOR STATIC CONE TEST The value c,f c shall be rrbtainet! from unetrnfil]wl compressive strength test. Alternatively, it can also be de] ivecl from stalic cone test The values of JC, dc and ie ma:; be obtaint+ as it! 5.1 If ( JCg5.3.1.2). the shear strength for a depth of ~i3 beneath the founciatioll does not by more tl-san 50 percent, the average may be depart from the average used in the calculation.
5.3.1.2 Alternately, cohesion c shall be determined from the static cone point resistance qe using the empirical relaticmship shown below:
Soil Typ Normally consol\dated clays Over consolidated clays
q. >
20
5.3.2 Two Lir~ertd Sjstem In the case of two layered cohesive stril system ~hich do not exhibit marked anisotropy the ultimate net bearing capacity of a strip footing can be calculated by using the formula given be[,~w:
qa c1 N.
from Fig. 3,
IS 6403:1981
5.3.3 Dcsiccatcd Soil In the case of desiccated cohesive soils, the undrained cohesion is likely to decrease along with depth and is likely to getstabilized atsomedeptll below grrJl]nd kvel, usually 35m, if other values as If u plot of undrained cohesion, factors do not influence. shown ir] Fig. 4 is obtained, anti where the pressure bulb falls within the desiccated top soil the ultimate net bearing capacity shall be obtained f]om Table 4.
c1
c, .
p
1 ;n~o
~P .
!p. ~
...- . . .,
1 .. <. ... . ,,
. ...!.
i:
.l.
. .. . . .
i - -~-;1
1 ~
,. ... L....-..
l---:VET/-TT--l---TT----!i t
bflmttt--l
BEARING
FIG. 3
IS 6403:1981
--
FXG. 4
BEARING
CAPACITY
FACTORS
FOR DESICCATED
COHESIVE
SOIL
ULTIMATE
NET
qd c1 00 02 97
04 06 08
10
so +5 40 !+6
32
from the borehole data, and for a known value footing B, by trial and error qa can be
of the width
estimated
with -f$.
qd
8AB
6. ALLOWABLE
BEARING
bearing is less:
CAPACITY
capacity shall be taken as either by
of the
suit-
a) Net ultimate bearing capacity as obtained in 5 divided able factor of safety, that is, net safe bearing capacity.
14
IS 6403: b;
1981
~he net soil pressure (~ec6.1.l ) that can beimposedon the base wi[t~out the settlement exceeding the permissible values as given iri IS : 1904- 1978* to be determined for each structure and type of soil, that is, safe bearing pressure.
settlements for different 6.1.1 Safe Bearing Prersure The permissible types of soil formations are specifiedin IS : 1904- ~978*. The methods for calculations of settlements for assumed pressure are specified in IS :8009 ( Part i )- 1976t; by calculating the settlements for two or three probable soil pressures and interpolating, the net soil pressure for permissible settlement may be estimated.
*Code of practice for structural safety of buildings: Shallow foundation ( swofid revision ). Part I Shallow foundations tCode of practice for calculation of foundations: subjcctcd to symmetrical static vertical loads.
15
IS 6403:
1981
Ikaririg
Capacitv
of I?oundaiiorl
Subctxnmittec,
13DC
43:4
BUREAU
INDIAN STANDARDS
Headquarters: Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002 Telephones. 3230131, 3233375, 3238402 Fax :91113234082, 91113239393, 91113239382 Tetegrams : Manaksanstha (Common to all Ofilces)
Central Laboratory:
Plot No. 20~, Sita Iv Sahibabad lndusVial Area, SAHIBABAD 201010 Raglonal Offices:
Te&@rone 8-770032
Cantml : Manak Bhavan, 9 Bahadur Shah Zatar Marg, NEW DELHI 110002 Eastern : 1/14 CIT Scheme Vll M, V.I.P. Road, Maniktola, CALCLJTTA700054 Northern : SCO 335-336, Sector 34-A, CHANDIGARH Southern : C.I.T. Campus, IV Cross Road, CHENNAI 160022 600113
tWestern : Manakalaya, E9 Behind Marol Tdephone Exchange, Andheri (East), MUMBAI 400093 Briwch
offlcaa:
Pushpak, Nurmohamed Shaikh Marg, Khanpur, AHMEDABAD 380001 $Paenya Industrial Area, 1st Stage, Bangalore - Tumkur Road, BANGALORE 560058 Gangotri Complex, 5th Floor, Bhadbhada Road, T. T. Nagar, BHOPAL 462003 Plot No, 62-63, Unit W, Ganga Nagar, BHUBANESHWAR 751001 Kaiaikathir Buildings, 670 Avinashi Road, COIMBATORE 641037 Plot No. 43, Sector 16 A, Mathura Road, FARIDABAD 121001 Savitri Complex, 116 G. T. Road, GHAZIABAD 201001 53/5 Ward No 29, R. G. Barua Road, 5UI By-lane, GUWAHATI 781003 5-8-58C, L. N. Gupta Marg, Nampally Station Road, HYDERABAD E-52, Chitararyan Marg, C-Scheme, JAIPUR 302001 117/41 8 B, Sarvodaya Nagar, KANPUR 208005 Seth Bhawart 2nd Floor, Behind Leela Cinema, Naval Kishore Road, LUCKNOW 226001 Patliputra Industrial Estate, PATNA 800013 T. C. No. 14/1421, University P. O. Palayam, THIRUVANANTHAPURAM 695034 NIT Building, Second Floor, Gokulpat Market, NAQPUR 440010 Institution of En@reers ( India ) Building, 1332 ShivaJi Nagar, PUNE 411005 Sales Office is at 5Chowringhea Approach, 1?O. Princap Street, CALCUTTA 700072 tSales Ofhce is at Novelty Chambers, Grant Road, MUMBAI 400007 &ales Otfrce is at F Block, Unity Building, Narashimaraja Square, BAN GALORE 560002 500001
5501348 8394955 554021 403627 21 01 41 8-288801 8-71 1996 541137 201083 372925 218876 238923 262305 621 5251 17 71
323635
AMENDMENT NO, 1 TO
MAY 1984
S.2,2, I.aetaentince)
for any the exhtlng sentence:
value shall values t more be for
the
In
computing
individual
50 percent of the average calculated than neglected end average re-calculated (the
all loose (Page seams 13, shall however be included).
cliwe 5.3.3):
3 - Substitute 6 Add the around* words failure with surfacef
a) b)
Mte Lhe
Of
for usually
the assumption after
cylindrical
for
the
cl/c2.
(Page 14, Fig. 4, capt~m) following for the existing caption: Decreasing Cohesion vith Depth
Substitute
in
Case
of Kh?siccated
Cohesive Soil
(Page 14,
Table 4 andctuaa
~
5.3.3)
Substitute
4AB
d
for 6AEI
(Page 25,
from standard
chuse Cl. 1, line 3) - Add the words pressure. penetration resistance after
-Add the
follouing
TMs safe bearing pressure cm also be calculated based on plate load test (See 1S:1888-1982s).
words
(Page 25, foot-note With * nmk) .-Add the of settlement after calculation. - Add the following additional
on soils
(second ZWV~8~~)t.
(73DC
43)